Gamma-Induced Image Degradation Analysis of Robot Vision Sensor for Autonomous Inspection of Nuclear Sites

Open access

Abstract

There is an increasing desire to conduct autonomous inspection of nuclear sites using robots. However, the presence of gamma radiation in nuclear sites induces degradation in vision sensors. In this paper, the effects of gamma radiation on a robot vision sensor (CMOS camera) used for radiological inspection is examined. The analyses have been carried out for two types of images at different dose rates: a) dark images b) illuminated images. In this work, dark images and chessboard images under illumination are analysed using various evaluation metrics to evaluate the effect of gamma radiation on CMOS Integrated Circuit (IC) and electronic circuitry of the sensor. Experimental results manifest significant changes in electrical properties like the generation of radiation-induced photo signal in sensing circuitry and radiation-induced noise affecting the visual odometry of the robot. System-level degradation for gamma dose rates upto 3 Gy/min intensifies, making data from the imaging sensor unreliable for the visual odometry. However, images captured for gamma dose rate upto 3 Gy/min can be used for surveillance purpose.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jsen.2021.3050168

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Distributed optical fibre sensors exposed to radiation can experience increased noise intensity.

    “Additionally, distributed optical fibre sensors exposed to radiation can experience increased noise intensity (Guo et al., 2024;Khanam et al., 2021).”

    From Impact of Sensor Degradation on Measurement Uncertainty in Prognostics and Maintenance Decision-Making: State of the art and challenges (2025) · cites this paper as Khanam et al., 2021

    In C. Results and Analysis, the paper reports that noise in a gamma-irradiated sensor increases with dose rate. III. Experimental Realization identifies that sensor as a Raspberry Pi CMOS camera, not a distributed optical fibre sensor. The radiation-related noise increase is supported, but its application to the specified sensor type is not. (LLM, conf=0.88)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 47

  1. 10.1109/AIM.2009.5229792 · DOI
  2. 10.1108/01439911211249715 · DOI
  3. 10.1109/MRA.2018.2879755 · DOI
  4. 10.1088/1757-899X/235/1/012003 · DOI
  5. 10.1109/TNS.2013.2259260 · DOI
  6. Schwank, Total dose effects in MOS devices, 111, 1
  7. 10.1109/TNS.2003.812928 · DOI
  8. Aslam, Measuring the degradation of commercial cameras under fast neutron beam, 1
  9. 10.1109/REDW.2019.8906531 · DOI
  10. 10.1109/JSEN.2014.2368139 · DOI
  11. 10.1109/TNS.2005.860708 · DOI
  12. 10.1109/TNS.2016.2636566 · DOI
  13. 10.1097/HP.0000000000000072 · DOI
  14. 10.1109/REDW.2002.1045527 · DOI
  15. 10.3390/s18020514 · DOI
  16. 10.1063/1.4943674 · DOI
  17. 10.1109/TNS.2018.2837015 · DOI
  18. 10.1109/TNS.2020.2990081 · DOI
  19. 10.1109/JSEN.2017.2732499 · DOI
  20. 10.1016/j.nima.2016.04.072 · DOI
  21. 10.1109/TNS.2012.2222927 · DOI
  22. 10.1109/TNS.2016.2641162 · DOI
  23. 10.1016/j.pnucene.2018.10.023 · DOI
  24. 10.1109/SENSORS43011.2019.8956620 · DOI
  25. 10.1007/978-1-4842-6348-8_8 · DOI
  26. 10.4016/26370.01 · DOI
  27. 2020, Trust USB Camera
  28. 10.1109/23.173235 · DOI
  29. 2011, Report of Japanese Government to the IAEA Ministerial Conference on Nuclear Safety: The Accident at TEPCO’s Fukushima Nuclear Power Station
  30. 10.2172/537279 · DOI
  31. 10.1088/1757-899X/452/4/042102 · DOI
  32. 10.1002/rob.21650 · DOI
  33. 10.1002/rob.21439 · DOI
  34. 2020, Highest Radiation Reading Since 3_11 Detected at Fukushima No. 1 Reactor
  35. 2020, Radiation Levels Now
  36. 2020, Dalton Cumbrian Facility
  37. 10.1109/IWISA.2010.5473273 · DOI
  38. 10.1145/3204493.3204584 · DOI
  39. 10.1109/IROS.2013.6696517 · DOI
  40. 10.1007/978-981-10-0755-2_38 · DOI
  41. 2010, Standard for Characterization of Image Sensors and Cameras
  42. Shin, An ergonomic evaluation of the illumination level and the management plan to improve the working environment of nuclear power plants, 1
  43. 10.1109/MRA.2011.943233 · DOI · Paper page
  44. 10.1109/ICCVW.2013.37 · DOI
  45. 10.1016/j.patrec.2011.07.021 · DOI
  46. 10.1109/TPAMI.2007.70787 · DOI
  47. Ali, Adversarial examples for handcrafted features, 1

Cited by

Sorted by citations

Metadata

Authors
Khanam, Z., Aslam, B., Saha, S., Zhai, X., Ehsan, S., Stolkin, R., & McDonald-Maier, K.
Affiliations
  • University of Essex (GB)
  • University of Birmingham (GB)
Venue
IEEE Sensors Journal
Published
2022-09-15
Volume
22
Issue
18
Pages
17378-17390
ISSN
  • 1530-437X (ISSN-L)
  • 1558-1748
  • 2379-9153
OpenAlex
W3118343494
Cited by
16
References
0
Citations by year
2026: 1 · 2025: 3 · 2024: 4 · 2023: 3 · 2022: 3
FWCI
0.87
Type
journal article
Language
en
Open access
Locations
  • IEEE Sensors Journal (publishedVersion, cc-by)
  • ePrints Soton (University of Southampton) (acceptedVersion)
  • Open Access at Essex (University of Essex) (acceptedVersion)
Funders
U.K. Engineering and Physical Sciences Research Council (EP/R02572X/1, EP/P017487/1)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › CCD and CMOS Imaging Sensors
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Radiation Effects in Electronics
  • Physical Sciences › Physics and Astronomy › Radiation › Radiation Detection and Scintillator Technologies
Keywords
gamma radiation, image degradation, CMOS camera, autonomous inspection, nuclear facilities, visual odometry, radiation-induced noise, dose rate, dark images, surveillance

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review