Cited by 18Analog and Mixed-Signal Circuit DesignGas Sensing Nanomaterials and SensorsSensor Technology and Measurement Systems

The DOI matches its Crossref record; the references it cites are not checked yet.

An Ultra-Low-Power Read-Out Circuit for Interfacing Novel Gas Sensors Matrices

Open access
Puyol, Rafael, Petre, Sylvain, Danlee, Yann, Walewyns, Thomas, Francis, Laurent A., Flandre, Denis·2022·IEEE Sensors Journal

Abstract

New gas sensing materials, like conductive polymers and nanomaterials-based composites, together with integrated circuit advancements have enabled a new paradigm in gas sensing where a matrix of different types of sensors is used to improve selectivity and sensitivity. In this paper we present a highly flexible read-out circuit for acquiring the dc resistance of the sensors in the matrix. It can measure values from 1$\text{k}\Omega $up to 33$\text{M}\Omega $, with a minimum SNR of 57 dB. It also offers a wide range of input configuration in terms of resistance and bias voltages to select the optimal bias point for each sensor and to accommodate a large range of sensor types. It achieves very low power consumption at a maximum current consumption of$194~\mu \text{A}$and an energy per conversion ranging from 1.21 nJ up to 188 nJ thanks to the optimization of the frequency of operation. The circuit was fabricated in a 180 nm bulk CMOS process and a complete characterization of the circuit is presented including current consumption, signal-to-noise ratio, and transfer function. Finally, the circuit was tested in a real application for the measurement of NH3and NO2using two different types of sensors validating the design objectives and the capability of the read-out circuit for system-on-chip integrations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jsen.2022.3165755

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

The citation lists haven’t been fetched yet

References 37 · Cited by 18

Research works printed but not linked: 37

  1. 10.3390/chemosensors3010001 · DOI
  2. 10.1109/ICASI.2018.8394393 · DOI
  3. 10.3390/app8071118 · DOI
  4. 10.1149/2.0032003jes · DOI
  5. 10.3390/ma14092347 · DOI
  6. 10.1039/C7RA02821K · DOI
  7. 10.1021/acsami.8b00853 · DOI
  8. 10.1016/j.snb.2015.05.107 · DOI
  9. 10.1016/j.mssp.2020.105332 · DOI
  10. 10.1039/d0ra07800j · DOI
  11. 10.1016/j.snb.2012.10.005 · DOI
  12. 10.1149/2162-8777/abe3ce · DOI
  13. 10.1016/j.carbon.2015.04.082 · DOI
  14. 10.1063/5.0040556 · DOI
  15. 10.1109/TRANSDUCERS.2017.7994034 · DOI
  16. 10.3390/proceedings2020056019 · DOI
  17. 10.3390/s21051802 · DOI
  18. 10.1016/S0925-4005(97)80125-6 · DOI
  19. 10.1155/2015/129678 · DOI
  20. 10.1016/0925-4005(95)01725-9 · DOI
  21. 10.1002/pi.1815 · DOI
  22. 10.4028/www.scientific.net/AMR.1167.43 · DOI
  23. 10.4236/msa.2015.611097 · DOI
  24. 10.3390/s17030562 · DOI
  25. 10.1109/VLSID.2012.66 · DOI
  26. 10.1109/ISSCC.2018.8310296 · DOI
  27. 10.1109/JSEN.2019.2939615 · DOI
  28. 10.1109/ICICDT.2018.8399751 · DOI
  29. 10.1109/NGCAS.2017.11 · DOI
  30. 10.1109/TCSI.2020.3047508 · DOI · Paper page
  31. 10.1109/JXCDC.2019.2928769 · DOI
  32. 10.1109/TCSI.2015.2452332 · DOI
  33. 10.1109/JSSC.2020.2987692 · DOI
  34. 10.1109/CICC.2012.6330702 · DOI
  35. 10.1109/VLSIC.2015.7231311 · DOI
  36. 10.1109/ISSCC.2015.7062848 · DOI
  37. 10.1109/TCSII.2014.2369111 · DOI

Metadata

Authors
Puyol, R., Petre, S., Danlee, Y., Walewyns, T., Francis, L. A., & Flandre, D.
Affiliations
  • UCLouvain (BE)
  • VOCSens, Ottignies-Louvain-la-Neuve, Belgium
Venue
IEEE Sensors Journal
Published
2022-05-15
Volume
22
Issue
10
Pages
9521-9533
ISSN
  • 1530-437X (ISSN-L)
  • 1558-1748
  • 2379-9153
OpenAlex
W4225361056
Cited by
18
References
37
Citations by year
2026: 3 · 2025: 5 · 2024: 3 · 2023: 5 · 2022: 2
FWCI
1.09
Type
journal article
Language
en
Open access
Locations
  • IEEE Sensors Journal (publishedVersion)
  • Digital Access to Libraries (Université catholique de Louvain (UCL), l'Université de Namur (UNamur) and the Université Saint-Louis (USL-B)) (submittedVersion, other-oa)
Funders
  • Wallonia
  • BioWin Cluster BioCloud4.0 Project
  • European Regional Development Fund (ERDF) and Wallonia
  • Micro Project
  • ERA-NET MANUNET Development of miniaturized smart wEarables with advanced Multidisciplinary Manufacturing Approach (EMMA) Project
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
  • Physical Sciences › Physics and Astronomy › Instrumentation › Sensor Technology and Measurement Systems
Keywords
sensor matrix, DC resistance measurement, conducting polymers, nanocomposites, 0.18 μm CMOS, NH3 sensing, NO2 gas sensing, system-on-chip integration, signal-to-noise ratio

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review