The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Active CMOS Sensor Array for Electrochemical Biomolecular Detection
Abstract
Electrochemical sensing of biomolecules eliminates the need for the bulky and expensive optical instrumentation required in traditional fluorescence-based sensing assays. Integration of the sensor interface electrodes and active electrochemical detection circuitry on a CMOS substrate miniaturizes the sensing platform, enhancing its portability for use in point-of-care applications, while enabling the high-throughput, highly parallel analysis characteristic of traditional microarrays. This paper describes the design of a four-by-four active sensor array for multiplexed electrochemical biomolecular detection in a standard 0.25-mum CMOS process. Integrated potentiostats, comprised of control amplifiers and dual-slope analog-to-digital converters, stimulate the electrochemical cell and detect the current flowing through the on-chip gold electrodes at each sensor site that results from biomolecular reactions occurring on the chip surface. Post-processing steps needed to fabricate a biologically-compatible surface-electrode array in CMOS that can withstand operation in a harsh electrochemical environment are also described. Experimental results demonstrating the proper operation of the active CMOS array for biomolecular detection include cyclic voltammetry of a reversible redox species, DNA probe density characterization, as well as quantitative and specific DNA hybridization detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214 · cited 1×
“Electrochemical sensing approaches to DNA detection, which have gained interest in recent years but are not yet as well-developed as optical techniques [ 5 ], rely on detecting changes occurring with hybridization at the interface between a metal “working” electrode (WE), functionalized with probe molecules, and a con…”
Background
Cited by
Smart Sensor Systems for Wearable Electronic Devices
An, B. W., Shin, J. H., Kim, S.-Y., Kim, J., Ji, S., Park, J., Lee, Y., Jang, J., Park, Y.-G., Cho, E., et al. (2017) · Polymers · doi:10.3390/polym9080303 · Cited by 289
Wearable multiplexed biosensor system toward continuous monitoring of metabolites
Yokus, M. A., Songkakul, T., Pozdin, V. A., Bozkurt, A., & Daniele, M. A. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112038 · Cited by 153
16-Channel CMOS Impedance Spectroscopy DNA Analyzer With Dual-Slope Multiplying ADCs
Jafari, H., Soleymani, L., & Genov, R. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2226334 · Cited by 122
Hybrid CMOS-Graphene Sensor Array for Subsecond Dopamine Detection
Nasri, B., Wu, T., Alharbi, A., You, K.-D., Gupta, M., Sebastian, S. P., Kiani, R., & Shahrjerdi, D. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2778048 · Cited by 33
Metadata
- Authors
- Levine, P. M., Gong, P., Levicky, R., & Shepard, K. L.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2008-08
- Volume
- 43
- Issue
- 8
- Pages
- 1859-1871
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W2128508216
- Cited by
- 195
- References
- 1
- FWCI
- 7.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Active CMOS Sensor Array for Electrochemical Biomolecular Detection. https://app.cochat.ai/papers/10.1109/jssc.2008.925407
- The paper
- Levine, P. M., Gong, P., Levicky, R., & Shepard, K. L. (2008). Active CMOS Sensor Array for Electrochemical Biomolecular Detection. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2008.925407
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.