The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A 20 mV Input Boost Converter With Efficient Digital Control for Thermoelectric Energy Harvesting
Abstract
This paper presents a low power boost converter for thermoelectric energy harvesting that demonstrates an efficiency that is 15% higher than the state-of-the-art for voltage conversion ratios above 20. This is achieved by utilizing a technique allowing synchronous rectification in the discontinuous conduction mode. A low-power method for input voltage monitoring is presented. The low input voltage requirements allow operation from a thermoelectric generator powered by body heat. The converter, fabricated in a 0.13 ¿m CMOS process, operates from input voltages ranging from 20 mV to 250 mV while supplying a regulated 1 V output. The converter consumes 1.6 (1.1) ¿W of quiescent power, delivers up to 25 (175) ¿W of output power, and is 46 (75)% efficient for a 20 mV and 100 mV input, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermoelectric Converters of Human Warmth for Self-Powered Wireless Sensor Nodes
Leonov, V., Torfs, T., Fiorini, P., & Van Hoof, C. (2007) · IEEE Sensors Journal · doi:10.1109/jsen.2007.894917 · Cited by 402
Resistor Emulation Approach to Low-Power RF Energy Harvesting
Paing, T., Shin, J., Zane, R., & Popovic, Z. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.921167 · Cited by 264
Suitability of a thermoelectric power generator for implantable medical electronic devices
Yang, Y., Wei, X.-J., & Liu, J. (2007) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/40/18/042 · Cited by 163
Cited by
Forouzesh, M., Siwakoti, Y. P., Gorji, S. A., Blaabjerg, F., & Lehman, B. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2652318 · Cited by 2,123
Energy harvesting in wireless sensor networks: A comprehensive review
Shaikh, F. K., & Zeadally, S. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.11.010 · Cited by 1,253
Energy harvesting: State-of-the-art
Harb, A. (2011) · Renewable Energy · doi:10.1016/j.renene.2010.06.014 · Cited by 696
Flexible thermoelectric materials and device optimization for wearable energy harvesting
Bahk, J.-H., Fang, H., Yazawa, K., & Shakouri, A. (2015) · Journal of Materials Chemistry C · doi:10.1039/c5tc01644d · Cited by 621
A Battery-Less Thermoelectric Energy Harvesting Interface Circuit With 35 mV Startup Voltage
Ramadass, Y. K., & Chandrakasan, A. P. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2074090 · Cited by 578
Metadata
- Authors
- Carlson, E. J., Strunz, K., & Otis, B. P.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2010-04
- Volume
- 45
- Issue
- 4
- Pages
- 741-750
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2122373168
- Cited by
- 488
- References
- 3
- FWCI
- 25.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A 20 mV Input Boost Converter With Efficient Digital Control for Thermoelectric Energy Harvesting. https://app.cochat.ai/papers/10.1109/jssc.2010.2042251
- The paper
- Carlson, E. J., Strunz, K., & Otis, B. P. (2010). A 20 mV Input Boost Converter With Efficient Digital Control for Thermoelectric Energy Harvesting. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2010.2042251
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.