A 2.3 $\mu$W Wireless Intraocular Pressure/Temperature Monitor
The DOI matches its Crossref record.
Abstract
We present the design of an ultra-low power, wireless pressure/temperature sensing device for continuous intraocular pressure monitoring. The device is wirelessly powered and demonstrates a power consumption of 2.3 μW at 1.5 V during continuous monitoring. The chip converts both capacitance and temperature to frequency using a time-interleaved relaxation oscillator, which modulates RF backscatter to a reader for computation of measured samples. A significant reduction in power consumption results from the elimination of the digitization circuitry, time-multiplexed operation, and moving the signal processing burden to the external reader using analog IF-modulated backscatter. The chip exhibits measured capacitance and temperature standard deviations of 1.4 fF and 0.4°C, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Roy, S., Azad, A. N. M. W., Baidya, S., Alam, M. K., & Khan, F. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3164890 · Cited by 255
A mm-Sized Wireless Implantable Device for Electrical Stimulation of Peripheral Nerves
Charthad, J., Chang, T. C., Liu, Z., Sawaby, A., Weber, M. J., Baker, S., Gore, F., Felt, S. A., & Arbabian, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2799623 · Cited by 230
Self‐Powered Implantable Medical Devices: Photovoltaic Energy Harvesting Review
Zhao, J., Ghannam, R., Htet, K. O., Liu, Y., Law, M., Roy, V. A. L., Michel, B., Imran, M. A., & Heidari, H. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.202000779 · Cited by 218
A review of acoustic power transfer for bio-medical implants
Basaeri, H., Christensen, D. B., & Roundy, S. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/12/123001 · Cited by 202
A batteryless energy harvesting storage system for implantable medical devices demonstrated in situ
Gall, O. Z., Meng, C., Bhamra, H., Mei, H., John, S. W. M., & Irazoqui, P. P. (2019) · Circuits, Systems, and Signal Processing · doi:10.1007/s00034-018-0915-4 · Cited by 13
Metadata
- Authors
- Shih, Y.-C., Shen, T., & Otis, B. P.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2011-11
- Volume
- 46
- Issue
- 11
- Pages
- 2592-2601
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2567311997
- Cited by
- 77
- References
- 0
- FWCI
- 3.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A 2.3 $\mu$W Wireless Intraocular Pressure/Temperature Monitor. https://app.cochat.ai/papers/10.1109/jssc.2011.2164134
- The paper
- Shih, Y.-C., Shen, T., & Otis, B. P. (2011). A 2.3 $\mu$W Wireless Intraocular Pressure/Temperature Monitor. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2011.2164134
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.