The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Polymer microring resonators for biochemical sensing applications
Abstract
Polymer microring resonators were demonstrated for sensing biomolecules without using fluorescent labels. The microring devices, fabricated by a direct imprinting technique, possess high Q factors of /spl sim/20000. This feature provides high sensitivity and a low detection limit for biochemical sensing applications. With these properties, the devices were used to detect and quantify the biomolecules present either in a homogeneous solution that surrounds the microring waveguide (homogeneous sensing) or specifically bound on the waveguide surface (surface sensing). In the former sensing mechanism, the current devices can detect an effective index change of 10/sup -7/ refractive index units (RIU); in the latter, they can reach a detection limit of /spl sim/250 pg/mm/sup 2/ of biomolecular coverage on the microring surface. In addition, the experiments show that the devices can detect both small and large biomolecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultra-high-Q toroid microcavity on a chip
Armani, D. K., Kippenberg, T. J., Spillane, S. M., & Vahala, K. J. (2003) · Nature · doi:10.1038/nature01371 · Cited by 2,214
Cited by
Optical ring resonators for biochemical and chemical sensing
Sun, Y., & Fan, X. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4237-z · Cited by 355
Metadata
- Authors
- Chao, C.-Y., Fung, W., & Guo, L. J.
- Venue
- IEEE Journal of Selected Topics in Quantum Electronics
- Published
- 2006-01
- Volume
- 12
- Issue
- 1
- Pages
- 134-142
- ISSN
- 1077-260X (ISSN-L)
- OpenAlex
- W2116416536
- Cited by
- 442
- References
- 1
- FWCI
- 33.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Polymer microring resonators for biochemical sensing applications. https://app.cochat.ai/papers/10.1109/jstqe.2005.862945
- The paper
- Chao, C.-Y., Fung, W., & Guo, L. J. (2006). Polymer microring resonators for biochemical sensing applications. IEEE Journal of Selected Topics in Quantum Electronics. https://doi.org/10.1109/jstqe.2005.862945
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.