The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Polymer microring resonators for biochemical sensing applications
Abstract
Polymer microring resonators were demonstrated for sensing biomolecules without using fluorescent labels. The microring devices, fabricated by a direct imprinting technique, possess high Q factors of /spl sim/20000. This feature provides high sensitivity and a low detection limit for biochemical sensing applications. With these properties, the devices were used to detect and quantify the biomolecules present either in a homogeneous solution that surrounds the microring waveguide (homogeneous sensing) or specifically bound on the waveguide surface (surface sensing). In the former sensing mechanism, the current devices can detect an effective index change of 10/sup -7/ refractive index units (RIU); in the latter, they can reach a detection limit of /spl sim/250 pg/mm/sup 2/ of biomolecular coverage on the microring surface. In addition, the experiments show that the devices can detect both small and large biomolecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface plasmon resonance sensors: review
Homola, J., Yee, S. S., & Gauglitz, G. (1999) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(98)00321-9 · Cited by 5,453
All About Albumin: Biochemistry, Genetics, and Medical Applications
Peters, T. (1995) · Thammasat University Digital Collections · Cited by 3,372
Present and future of surface plasmon resonance biosensors
Homola, J. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2101-0 · Cited by 2,321
Ultra-high-Q toroid microcavity on a chip
Armani, D. K., Kippenberg, T. J., Spillane, S. M., & Vahala, K. J. (2003) · Nature · doi:10.1038/nature01371 · Cited by 2,214 · cited 1×
“The existence of biomolecules might change absorption of light and lead to resonance broadening [27], but this can be mostly avoided by choosing the resonance wavelength to be outside the main absorption range of the molecules.”
BackgroundSub-10 nm imprint lithography and applications
Chou, S. Y., Krauss, P. R., Zhang, W., Guo, L., & Zhuang, L. (1997) · Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena · doi:10.1116/1.589752 · Cited by 1,113
Self-citationUltimate Q of optical microsphere resonators
Gorodetsky, M. L., Savchenkov, A. A., & Ilchenko, V. S. (1996) · Optics Letters · doi:10.1364/ol.21.000453 · Cited by 1,035
Protein detection by optical shift of a resonant microcavity
Vollmer, F., Braun, D., Libchaber, A., Khoshsima, M., Teraoka, I., & Arnold, S. (2002) · Applied Physics Letters · doi:10.1063/1.1482797 · Cited by 903
The biotin-(strept)avidin system: principles and applications in biotechnology
Diamandis, E. P., & Christopoulos, T. K. (1991) · Clinical Chemistry · doi:10.1093/clinchem/37.5.625 · Cited by 747
Biochemical sensors based on polymer microrings with sharp asymmetrical resonance
Chao, C.-Y., & Guo, L. J. (2003) · Applied Physics Letters · doi:10.1063/1.1605261 · Cited by 470
Self-citationSensitive disk resonator photonic biosensor
Boyd, R. W., & Heebner, J. E. (2001) · Applied Optics · doi:10.1364/ao.40.005742 · Cited by 399
NISHIHARA, H. (1980) · The Review of Laser Engineering · doi:10.2184/lsj.8.632 · Cited by 365
Collings, A. F., & Caruso, F. (1997) · Reports on Progress in Physics · doi:10.1088/0034-4885/60/11/005 · Cited by 258
Sensor based on an integrated optical microcavity
Krioukov, E., Klunder, D. J. W., Driessen, A., Greve, J., & Otto, C. (2002) · Optics Letters · doi:10.1364/ol.27.000512 · Cited by 231
SCISSOR solitons and other novel propagation effects in microresonator-modified waveguides
Heebner, J. E., Boyd, R. W., & Park, Q.-H. (2002) · Journal of the Optical Society of America B · doi:10.1364/josab.19.000722 · Cited by 180
Resonant-enhanced evanescent-wave fluorescence biosensing with cylindrical optical cavities
Blair, S., & Chen, Y. (2001) · Applied Optics · doi:10.1364/ao.40.000570 · Cited by 159
Polarization conversion in ring resonator phase shifters
Melloni, A. I., Morichetti, F., & Martinelli, M. (2004) · Optics Letters · doi:10.1364/ol.29.002785 · Cited by 57
Chao, C.-Y., & Guo, L. J. (2004) · Applied Physics Letters · doi:10.1063/1.1691492 · Cited by 38
Self-citation
Cited by
Sensitive optical biosensors for unlabeled targets: A review
Fan, X., White, I. M., Shopova, S. I., Zhu, H., Suter, J. D., & Sun, Y. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.05.022 · Cited by 2,187
Nanoimprint Lithography: Methods and Material Requirements
Guo, L. J. (2007) · Advanced Materials · doi:10.1002/adma.200600882 · Cited by 1,842
Self-citationWhispering-gallery-mode biosensing: label-free detection down to single molecules
Vollmer, F., & Arnold, S. (2008) · Nature Methods · doi:10.1038/nmeth.1221 · Cited by 1,660
On the performance quantification of resonant refractive index sensors
White, I. M., & Fan, X. (2008) · Optics Express · doi:10.1364/oe.16.001020 · Cited by 1,105
Integrated optofluidics: A new river of light
Monat, C., Domachuk, P., & Eggleton, B. J. (2007) · Nature Photonics · doi:10.1038/nphoton.2006.96 · Cited by 955
Metadata
- Authors
- Chao, C.-Y., Fung, W., & Guo, L. J.
- Venue
- IEEE Journal of Selected Topics in Quantum Electronics
- Published
- 2006-01
- Volume
- 12
- Issue
- 1
- Pages
- 134-142
- ISSN
- 1077-260X (ISSN-L)
- OpenAlex
- W2116416536
- Cited by
- 442
- References
- 17
- FWCI
- 33.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.