Quasi-automatic phase-control technique for chirp compensation of pulses with over-one-octave bandwidth-generation of few- to mono-cycle optical pulses
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper introduces our self-recognition type of the computer-controlled spectral phase compensator (SRCSC), which consists of a greatly accurate phase manipulator with a spatial light modulator (SLM), a highly sensitive phase characterizer using a modified spectral phase interferometry for direct electric field reconstruction (M-SPIDER), and a computer for phase analysis and SLM control operating in the immediate feedback (FB) mode. The application of the SRCSC to adaptive compensation of various kinds of complicated spectral phases such as nonlinear chirped pulses with a weak intensity, induced-phase modulated pulses, photonic-crystal-fiber (PCF) output pulses, and nonlinear chirped pulses exceeding a 500-rad phase variation over-one-octave bandwidth demonstrated that the SRCSC is significantly useful for compensation of arbitrary nonlinear chirp and hence enables us to generate quasi-monocycle transform-limited (TL) pulses with a 2.8-fs duration. To the best of our knowledge, this 1.5-cycle pulse is the shortest single pulse with a clean temporal profile in the visible to near-infrared region.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Attosecond control of electronic processes by intense light fields
Baltuška, A., Udem, T., Uiberacker, M., Hentschel, M., Goulielmakis, E., Gohle, C., Holzwarth, R., Yakovlev, V. S., Scrinzi, A., Hänsch, T. W., et al. (2003) · Nature · doi:10.1038/nature01414 · Cited by 1,653 · cited 1×
“For example, the control of the electric-field wave packet but not the pulse intensity envelope is significantly important for the production of single attosecond pulses by the high-order harmonic generation using CEP controlled high-intensity pulses [ 36 ].”
Method
Cited by
Krausz, F., & Ivanov, M. (2009) · Reviews of Modern Physics · doi:10.1103/revmodphys.81.163 · Cited by 5,468
Wirth, A., Hassan, M. T., Grguraš, I., Gagnon, J., Moulet, A., Luu, T. T., Pabst, S., Santra, R., Alahmed, Z. A., Azzeer, A. M., et al. (2011) · Science · doi:10.1126/science.1210268 · Cited by 664
Coherent pulse synthesis: towards sub-cycle optical waveforms
Manzoni, C., Mücke, O. D., Cirmi, G., Fang, S., Moses, J., Huang, S.-W., Hong, K.-H., Cerullo, G., & Kärtner, F. X. (2015) · Laser & Photonics Reviews · doi:10.1002/lpor.201400181 · Cited by 225
Cavalieri, A. L., Goulielmakis, E., Horvath, B., Helml, W., Schultze, M., Fieß, M., Pervak, V, Veisz, L., Yakovlev, V. S., Uiberacker, M., et al. (2007) · New Journal of Physics · doi:10.1088/1367-2630/9/7/242 · Cited by 197
Metadata
- Authors
- Yamashita, M., Yamane, K., & Morita, R.
- Venue
- IEEE Journal of Selected Topics in Quantum Electronics
- Published
- 2006-03
- Volume
- 12
- Issue
- 2
- Pages
- 213-222
- ISSN
- 1077-260X (ISSN-L)
- OpenAlex
- W2161737466
- Cited by
- 46
- References
- 1
- FWCI
- 6.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.