The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Coherent X-Ray Diffraction Imaging
Abstract
For centuries, lens-based microscopy, such as optical, phase-contrast, fluorescence, confocal, and electron microscopy, has played an important role in the evolution of modern science and technology. In 1999, a novel form of microscopy, i.e., coherent diffraction imaging (also termed coherent diffraction microscopy or lensless imaging), was developed and transformed our conventional view of microscopy, in which the diffraction pattern of a noncrystalline specimen or a nanocrystal was first measured and then directly phased to obtain a high-resolution image. The well-known phase problem was solved by combining the oversampling method with iterative algorithms. In this paper, we will briefly discuss the principle of coherent diffraction imaging, present various implementation schemes of this imaging modality, and illustrate its broad applications in materials science, nanoscience, and biology. As coherent X-ray sources such as high harmonic generation and X-ray free-electron lasers are presently under rapid development worldwide, coherent diffraction imaging can potentially be applied to perform high-resolution imaging of materials/nanoscience and biological specimens at the femtosecond time scale.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Plasma perspective on strong field multiphoton ionization
Corkum, P. B. (1993) · Physical Review Letters · doi:10.1103/physrevlett.71.1994 · Cited by 7,217
Observation of a Train of Attosecond Pulses from High Harmonic Generation
Paul, P. M., Toma, E. S., Breger, P., Mullot, G., Augé, F., Balcou, P., Muller, H. G., & Agostini, P. (2001) · Science · doi:10.1126/science.1059413 · Cited by 2,801
Potential for biomolecular imaging with femtosecond X-ray pulses
Neutze, R., Wouts, R., van der Spoel, D., Weckert, E., & Hajdu, J. (2000) · Nature · doi:10.1038/35021099 · Cited by 2,022
Siemens, M. E., Li, Q., Yang, R., Nelson, K. A., Anderson, E. H., Murnane, M. M., & Kapteyn, H. C. (2010) · Nature Materials · doi:10.1038/nmat2568 · Cited by 443
Phase Matching of High-Order Harmonics in Hollow Waveguides
Durfee, C. G., Rundquist, A. R., Backus, S., Herne, C., Murnane, M. M., & Kapteyn, H. C. (1999) · Physical Review Letters · doi:10.1103/physrevlett.83.2187 · Cited by 361
Cited by
Morphology characterization in organic and hybrid solar cells
Chen, W., Nikiforov, M. P., & Darling, S. B. (2012) · Energy & Environmental Science · doi:10.1039/c2ee22056c · Cited by 400
Metadata
- Authors
- Miao, J., Sandberg, R. L., & Song, C.
- Venue
- IEEE Journal of Selected Topics in Quantum Electronics
- Published
- 2012-01
- Volume
- 18
- Issue
- 1
- Pages
- 399-410
- ISSN
- 1077-260X (ISSN-L)
- 1558-4542
- OpenAlex
- W2094960043
- Cited by
- 172
- References
- 5
- FWCI
- 9.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coherent X-Ray Diffraction Imaging. https://app.cochat.ai/papers/10.1109/jstqe.2011.2157306
- The paper
- Miao, J., Sandberg, R. L., & Song, C. (2012). Coherent X-Ray Diffraction Imaging. IEEE Journal of Selected Topics in Quantum Electronics. https://doi.org/10.1109/jstqe.2011.2157306
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.