The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
A STATCOM-Control Scheme for Grid Connected Wind Energy System for Power Quality Improvement
Abstract
Injection of the wind power into an electric grid affects the power quality. The performance of the wind turbine and thereby power quality are determined on the basis of measurements and the norms followed according to the guideline specified in International Electro-technical Commission standard, IEC-61400. The influence of the wind turbine in the grid system concerning the power quality measurements are-the active power, reactive power, variation of voltage, flicker, harmonics, and electrical behavior of switching operation and these are measured according to national/international guidelines. The paper study demonstrates the power quality problem due to installation of wind turbine with the grid. In this proposed scheme STATic COMpensator (STATCOM) is connected at a point of common coupling with a battery energy storage system (BESS) to mitigate the power quality issues. The battery energy storage is integrated to sustain the real power source under fluctuating wind power. The STATCOM control scheme for the grid connected wind energy generation system for power quality improvement is simulated using MATLAB/SIMULINK in power system block set. The effectiveness of the proposed scheme relives the main supply source from the reactive power demand of the load and the induction generator. The development of the grid co-ordination rule and the scheme for improvement in power quality norms as per IEC-standard on the grid has been presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey
Carrasco, J. M., Franquelo, L. G., Bialasiewicz, J. T., Galvan, E., PortilloGuisado, R. C., Prats, M. A. M., Leon, J. I., & Moreno-Alfonso, N. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878356 · Cited by 4,018
A review of grid code technical requirements for wind farms
Tsili, M., & Papathanassiou, S. (2009) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2008.0070 · Cited by 1,373
Comparison of Control Strategies for Shunt Active Power Filters in Three-Phase Four-Wire Systems
Montero, M. I. M., Cadaval, E. R., & Gonzalez, F. B. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.886616 · Cited by 582
STATCOM Impact Study on the Integration of a Large Wind Farm into a Weak Loop Power System
Han, C., Huang, A. Q., Baran, M. E., Bhattacharya, S., Litzenberger, W., Anderson, L., Johnson, A. L., & Edris, A.-A. (2008) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.888031 · Cited by 307
Kinjo, T., Senjyu, T. S., Urasaki, N., et al. (2006) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.853752 · Cited by 236
Cited by
Wali, S. B., Hannan, M. A., Reza, M. S., Ker, P. J., Begum, R. A., Rahman, M. S. A., & Mansor, M. (2021) · Journal of Energy Storage · doi:10.1016/j.est.2021.102296 · Cited by 149
Metadata
- Authors
- Mohod, S. W., & Aware, M. V.
- Venue
- IEEE Systems Journal
- Published
- 2010-09
- Volume
- 4
- Issue
- 3
- Pages
- 346-352
- ISSN
- 1932-8184 (ISSN-L)
- 1937-9234
- OpenAlex
- W2101702071
- Cited by
- 270
- References
- 5
- FWCI
- 12.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A STATCOM-Control Scheme for Grid Connected Wind Energy System for Power Quality Improvement. https://app.cochat.ai/papers/10.1109/jsyst.2010.2052943
- The paper
- Mohod, S. W., & Aware, M. V. (2010). A STATCOM-Control Scheme for Grid Connected Wind Energy System for Power Quality Improvement. IEEE Systems Journal. https://doi.org/10.1109/jsyst.2010.2052943
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.