The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Comparison of Control Strategies for Shunt Active Power Filters in Three-Phase Four-Wire Systems
Abstract
Strategies for extracting the three-phase reference currents for shunt active power filters are compared, evaluating their performance under different source and load conditions with the new IEEE Standard 1459 power definitions. The study was applied to a three-phase four-wire system in order to include imbalance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Akagi, H., Kanazawa, Y., & Nabae, A. (1984) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1984.4504460 · Cited by 3,377
Peng, F. Z., Ott, G. W., & Adams, D. J. (1998) · IEEE Transactions on Power Electronics · doi:10.1109/63.728344 · Cited by 469
Cited by
Flexible Active Power Control of Distributed Power Generation Systems During Grid Faults
Rodriguez, P., Timbus, A. V., Teodorescu, R., Liserre, M., & Blaabjerg, F. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.899914 · Cited by 726
A STATCOM-Control Scheme for Grid Connected Wind Energy System for Power Quality Improvement
Mohod, S. W., & Aware, M. V. (2010) · IEEE Systems Journal · doi:10.1109/jsyst.2010.2052943 · Cited by 270
Martinek, R., Bilik, P., Baros, J., Brablik, J., Kahankova, R., Jaros, R., Danys, L., Rzidky, J., & Wen, H. (2020) · Sensors · doi:10.3390/s20061718 · Cited by 31
Metadata
- Authors
- Montero, M. I. M., Cadaval, E. R., & Gonzalez, F. B.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2007-01
- Volume
- 22
- Issue
- 1
- Pages
- 229-236
- ISSN
- 0885-8993 (ISSN-L)
- OpenAlex
- W2115175721
- Cited by
- 582
- References
- 2
- FWCI
- 22.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Control Strategies for Shunt Active Power Filters in Three-Phase Four-Wire Systems. https://app.cochat.ai/papers/10.1109/tpel.2006.886616
- The paper
- Montero, M. I. M., Cadaval, E. R., & Gonzalez, F. B. (2007). Comparison of Control Strategies for Shunt Active Power Filters in Three-Phase Four-Wire Systems. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2006.886616
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.