The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Fuzzy Logic-Based Load-Frequency Control Concerning High Penetration of Wind Turbines
Abstract
Load-frequency control (LFC) in interconnected power systems is undergoing fundamental changes due to rapidly growing amount of wind turbines, and emerging of new types of power generation/consumption technologies. The infrastructure of modern LFC systems should be able to handle complex multiobjective regulation optimization problems characterized by a high degree of diversification in policies, and widely distribution in demand and supply sources to ensure that the LFC systems are capable to maintain generation-load balance, following serious disturbances. Wind power fluctuations impose additional power imbalance to the power system and cause frequency deviation from the nominal value. This paper addresses a new decentralized fuzzy logic-based LFC schemes for simultaneous minimization of system frequency deviation and tie-line power changes, which is required for successful operation of interconnected power systems in the presence of high-penetration wind power. In order to obtain an optimal performance, the particle swarm optimization technique is used to determine membership functions parameters. The physical and engineering aspects have been fully considered, and to demonstrate effectiveness of the proposed control scheme, a time domain simulation is performed on the standard 39-bus test system. The results are compared with conventional LFC design for serious load disturbance and various rates of wind power penetrations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new optimizer using particle swarm theory
Eberhart, R., & Kennedy, J. (2002) · MHS'95. Proceedings of the Sixth International Symposium on Micro Machine and Human Science · doi:10.1109/mhs.1995.494215 · Cited by 16,067
Cited by
Intelligent Frequency Control in an AC Microgrid: Online PSO-Based Fuzzy Tuning Approach
Bevrani, H., Habibi, F., Babahajyani, P., Watanabe, M., & Mitani, Y. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2196806 · Cited by 599
Self-citationPandey, S. K., Mohanty, S. R., & Kishor, N. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.04.029 · Cited by 561
Load Frequency Control of a Multi-Area Power System: An Adaptive Fuzzy Logic Approach
Yousef, H. A., AL-Kharusi, K., Albadi, M. H., & Hosseinzadeh, N. (2014) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2297432 · Cited by 314
Metadata
- Authors
- Bevrani, H., & Daneshmand, P. R.
- Venue
- IEEE Systems Journal
- Published
- 2012-03
- Volume
- 6
- Issue
- 1
- Pages
- 173-180
- ISSN
- 1932-8184 (ISSN-L)
- 1937-9234
- OpenAlex
- W2025862971
- Cited by
- 251
- References
- 1
- FWCI
- 5.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fuzzy Logic-Based Load-Frequency Control Concerning High Penetration of Wind Turbines. https://app.cochat.ai/papers/10.1109/jsyst.2011.2163028
- The paper
- Bevrani, H., & Daneshmand, P. R. (2012). Fuzzy Logic-Based Load-Frequency Control Concerning High Penetration of Wind Turbines. IEEE Systems Journal. https://doi.org/10.1109/jsyst.2011.2163028
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.