Load Frequency Control of a Multi-Area Power System: An Adaptive Fuzzy Logic Approach
Open accessAbstract
In this paper, a new load frequency control (LFC) for multi-area power systems is developed based on the direct-indirect adaptive fuzzy control technique. LFCs for each area are designed based on availability of frequency deviation of each area and tie-line power deviation between areas. The fuzzy logic system approximation capabilities are exploited to develop suitable adaptive control law and parameter update algorithms for unknown interconnected LFC areas. An H∞tracking performance criterion is introduced to minimize the approximation errors and the external disturbance effects. The proposed controller guarantees stability of the overall closed-loop system. Simulation results for a real three-area power system prove the effectiveness of the proposed LFC and show its superiority over a classical PID controller and a type-2 fuzzy controller.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Delay-Dependent Stability for Load Frequency Control With Constant and Time-Varying Delays
Jiang, L., Yao, W., Wu, Q. H., Wen, J. Y., & Cheng, S. J. (2012) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2011.2172821 · Cited by 604
Load frequency control strategies: A state-of-the-art survey for the researcher
Shayeghi, H., Shayanfar, H. A., & Jalili, A. (2008) · Energy Conversion and Management · doi:10.1016/j.enconman.2008.09.014 · Cited by 550
Unified Tuning of PID Load Frequency Controller for Power Systems via IMC
Tan, W. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2036463 · Cited by 526
Adaptive fuzzy gain scheduling for load frequency control
Talaq, J., & Al-Basri, F. (1999) · IEEE Transactions on Power Systems · doi:10.1109/59.744505 · Cited by 370
Intelligent Automatic Generation Control
Bevrani, H., & Hiyama, T. (2011) · International Linear Collider · Cited by 297
Linear State‐Space Control Systems
Williams, R. L., & Lawrence, D. A. (2007) · Wiley eBooks · doi:10.1002/9780470117873 · Cited by 293
Fuzzy Logic-Based Load-Frequency Control Concerning High Penetration of Wind Turbines
Bevrani, H., & Daneshmand, P. R. (2012) · IEEE Systems Journal · doi:10.1109/jsyst.2011.2163028 · Cited by 251
A robust decentralized load frequency controller for interconnected power systems
Dong, L., Zhang, Y., & Gao, Z. (2012) · ISA Transactions · doi:10.1016/j.isatra.2012.02.004 · Cited by 225
Fuzzy logic controller in interconnected electrical power systems for load-frequency control
Kocaarslan, İ., & Çam, E. (2005) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2005.06.003 · Cited by 212
Cited by
Yan, Z., & Xu, Y. (2020) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.2999890 · Cited by 398
Alhelou, H. H., Hamedani-Golshan, M.-E., Zamani, R., Heydarian-Forushani, E., & Siano, P. (2018) · Energies · doi:10.3390/en11102497 · Cited by 349
Metadata
- Authors
- Yousef, H. A., AL-Kharusi, K., Albadi, M. H., & Hosseinzadeh, N.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2014-07
- Volume
- 29
- Issue
- 4
- Pages
- 1822-1830
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2055754653
- Cited by
- 314
- References
- 14
- FWCI
- 14.50
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Load Frequency Control of a Multi-Area Power System: An Adaptive Fuzzy Logic Approach. https://app.cochat.ai/papers/10.1109/tpwrs.2013.2297432
- The paper
- Yousef, H. A., AL-Kharusi, K., Albadi, M. H., & Hosseinzadeh, N. (2014). Load Frequency Control of a Multi-Area Power System: An Adaptive Fuzzy Logic Approach. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2013.2297432
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.