Real-Time Detection of False Data Injection in Smart Grid Networks: An Adaptive CUSUM Method and Analysis
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
A smart grid is delay sensitive and requires the techniques that can identify and react on the abnormal changes (i.e., system fault, attacker, shortcut, etc.) in a timely manner. In this paper, we propose a real-time detection scheme against false data injection attack in smart grid networks. Unlike the classical detection test, the proposed algorithm is able to tackle the unknown parameters with low complexity and process multiple measurements at once, leading to a shorter decision time and a better detection accuracy. The objective is to detect the adversary as quickly as possible while satisfying certain detection error constraints. A Markov-chain-based analytical model is constructed to systematically analyze the proposed scheme. With the analytical model, we are able to configure the system parameters for guaranteed performance in terms of false alarm rate, average detection delay, and missed detection ratio under a detection delay constraint. The simulations are conducted with MATPOWER 4.0 package for different IEEE test systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fundamentals of Statistical Signal Processing: Estimation Theory
Sengijpta, S. K. (1995) · Technometrics · doi:10.1080/00401706.1995.10484391 · Cited by 11,076
Power Generation, Operation, and Control
Wood, A. J., & Wollenberg, B. F. (1984) · Cited by 8,303
Zimmerman, R. D., Murillo-Sanchez, C. E., & Thomas, R. J. (2011) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2051168 · Cited by 6,756 · cited 1×
“0 package [22] for different IEEE test systems to ensure the”
BackgroundPAGE, E. S. (1954) · Biometrika · doi:10.1093/biomet/41.1-2.100 · Cited by 5,739 · cited 2×
“However, most CUSUM-based models assume the perfect knowledge of the likelihood functions [26].”
MethodDetection of Abrupt Changes: Theory and Application
Riedel, K. S. (1994) · Technometrics · doi:10.1080/00401706.1994.10485821 · Cited by 3,518
Abur, A., & Expósito, A. G. (2004) · CRC Press eBooks · doi:10.1201/9780203913673 · Cited by 2,974 · cited 3×
“While the conventional state estimation [20], [21] for BDD focuses on”
BackgroundMethodMarkov Chain Monte Carlo: Stochastic Simulation for Bayesian Inference
Strawderman, R. L., & Gamerman, D. (2000) · Journal of the American Statistical Association · doi:10.2307/2669581 · Cited by 1,909 · cited 4×
“As described in [34], EP[FAR] is equivalent to the probability that Sn stays at state UF (i.”
BackgroundMethodInfluentialHill, P. G. (1977) · Cited by 1,394
Power System Static-State Estimation, Part I: Exact Model
Schweppe, F., & Wildes, J. (1970) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1970.292678 · Cited by 1,383
Procedures for Reacting to a Change in Distribution
Lorden, G. (1971) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177693055 · Cited by 1,351 · cited 1×
“As the value of an in (11) is unknown, the author in [28] proposed to implement the GLRT in the Page’s CUSUM algorithm with the unknown.”
Method
Cited by
A survey on security control and attack detection for industrial cyber-physical systems
Ding, D., Han, Q.-L., Xiang, Y., Ge, X., & Zhang, X.-M. (2018) · Neurocomputing · doi:10.1016/j.neucom.2017.10.009 · Cited by 944
A Survey on the Detection Algorithms for False Data Injection Attacks in Smart Grids
Musleh, A. S., Chen, G., & Dong, Z. Y. (2020) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2019.2949998 · Cited by 714
Cyber‐physical attacks and defences in the smart grid: a survey
He, H., & Yan, J. (2016) · IET Cyber-Physical Systems: Theory & Applications · doi:10.1049/iet-cps.2016.0019 · Cited by 454
Distributed Control Strategies for Microgrids: An Overview
Espina, E., Llanos, J., Burgos-Mellado, C., Cardenas-Dobson, R., Martinez-Gomez, M., & Saez, D. (2020) · IEEE Access · doi:10.1109/access.2020.3032378 · Cited by 415
Alotaibi, I., Abido, M. A., Khalid, M., & Savkin, A. V. (2020) · Energies · doi:10.3390/en13236269 · Cited by 314
Distributed Control and Communication Strategies in Networked Microgrids
Zhou, Q., Shahidehpour, M., Paaso, A., Bahramirad, S., Alabdulwahab, A., & Abusorrah, A. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2020.3023963 · Cited by 307
Networked Microgrids: State-of-the-Art and Future Perspectives
Alam, M. N., Chakrabarti, S., & Ghosh, A. (2019) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2018.2881540 · Cited by 295
Mahmoud, M. S., Hamdan, M. M., & Baroudi, U. A. (2019) · Neurocomputing · doi:10.1016/j.neucom.2019.01.099 · Cited by 278
Faults in smart grid systems: Monitoring, detection and classification
Labrador Rivas, A. E., & Abrão, T. (2020) · Electric Power Systems Research · doi:10.1016/j.epsr.2020.106602 · Cited by 230
State of the art of cyber-physical systems security: An automatic control perspective
Zacchia Lun, Y., D’Innocenzo, A., Smarra, F., Malavolta, I., & Di Benedetto, M. D. (2019) · Journal of Systems and Software · doi:10.1016/j.jss.2018.12.006 · Cited by 211
Fault detection of networked dynamical systems: a survey of trends and techniques
Ju, Y., Tian, X., Liu, H., & Ma, L. (2021) · International Journal of Systems Science · doi:10.1080/00207721.2021.1998722 · Cited by 209
“For power systems, a real-time detection scheme has been proposed to detect attacks and system faults in Huang et al. (2016), and the attack detection and isolation have been investigated for the supervisory control and data acquisition according to the statistical detection theory (Do et al.,…”
MethodBrief Survey on Attack Detection Methods for Cyber-Physical Systems
Tan, S., Guerrero, J. M., Xie, P., Han, R., & Vasquez, J. C. (2020) · IEEE Systems Journal · doi:10.1109/jsyst.2020.2991258 · Cited by 208
Synchrony in Networked Microgrids Under Attacks
Abhinav, S., Modares, H., Lewis, F. L., Ferrese, F., & Davoudi, A. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2721382 · Cited by 187
Real-Time Detection of Hybrid and Stealthy Cyber-Attacks in Smart Grid
Kurt, M. N., Yilmaz, Y., & Wang, X. (2019) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2018.2854745 · Cited by 184
“For instance, in [26] and [27], cumulative sum (CUSUM)-based schemes are”
BackgroundJoint-Transformation-Based Detection of False Data Injection Attacks in Smart Grid
Singh, S. K., Khanna, K., Bose, R., Panigrahi, B. K., & Joshi, A. (2018) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2720726 · Cited by 179
Extremely Randomized Trees-Based Scheme for Stealthy Cyber-Attack Detection in Smart Grid Networks
Camana Acosta, M. R., Ahmed, S., Garcia, C. E., & Koo, I. (2020) · IEEE Access · doi:10.1109/access.2020.2968934 · Cited by 177
“In the literature, several approaches that do not use ML algorithms have been introduced for SCA-attack detection [4], [5].”
BackgroundDetection of False Data Injection Attacks in Smart Grids Based on Graph Signal Processing
Drayer, E., & Routtenberg, T. (2020) · IEEE Systems Journal · doi:10.1109/jsyst.2019.2927469 · Cited by 165
“, the work in [27] that compares the norms of attacked states against those of unattacked ones, or the work in [28] that proposes an adapted cumulative sum method, but these, too, cannot overcome the model’s inherent limitations in its detection capabilities of such attacks.”
Background
Metadata
- Authors
- Huang, Y., Tang, J., Cheng, Y., Li, H., Campbell, K. A., & Han, Z.
- Venue
- IEEE Systems Journal
- Published
- 2016-06
- Volume
- 10
- Issue
- 2
- Pages
- 532-543
- ISSN
- 1932-8184 (ISSN-L)
- 1937-9234
- 2373-7816
- OpenAlex
- W2313114883
- Cited by
- 177
- References
- 31
- FWCI
- 6.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.