Planning in Microgrids With Conservation of Voltage Reduction
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
The main focus of this paper is to find an upgrade plan for a microgrid. This plan includes system lines' upgrades, the place, and size of the new capacitors and DERs. As usual, the planning process is begun with the load forecasting. The main objectives include minimization of system upgrade cost, loss cost, loss cost in peak load, and finally demand cost. The last objective is realized here using the tap changer of the main station transformer and reactive power support of the sources available or planned for the future of the grid. This is always referred to as the conservation of voltage reduction. In order to consider the effects of bus voltages on the system demand, the ZIP model for the system loads is used. Particle swarm optimization is used to minimize the total cost. The line flow limits lower/upper bound on bus voltages and minimum/maximum producible active and reactive power from different sources are considered as the optimization constraints. The proposed algorithm is tested on the IEEE 69 bus test system and the results are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lee, K. S., & Geem, Z. W. (2005) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2004.09.007 · Cited by 1,772
Distribution System Modeling and Analysis
Kersting, W. (2012) · Electric Power Engineering Series · doi:10.1201/b12056-31 · Cited by 1,241
Determining the impact of distributed generation on power systems. I. Radial distribution systems
Barker, P. P., & De Mello, R. W. (2002) · 2000 Power Engineering Society Summer Meeting (Cat. No.00CH37134) · doi:10.1109/pess.2000.868775 · Cited by 1,208
A compensation-based power flow method for weakly meshed distribution and transmission networks
Shirmohammadi, D., Hong, H. W., Semlyen, A., & Luo, G. X. (1988) · IEEE Transactions on Power Systems · doi:10.1109/59.192932 · Cited by 1,182 · cited 1×
“Details of this method in the basic form were presented in [31]–[34].”
MethodA new structural optimization method based on the harmony search algorithm
Lee, K. S., & Geem, Z. W. (2004) · Computers & Structures · doi:10.1016/j.compstruc.2004.01.002 · Cited by 1,135 · cited 1×
“Harmony search algorithm (HSA) [35], [36], which is a meta-heuristic method, is used here to find the best plan.”
MethodA three-phase power flow method for real-time distribution system analysis
Cheng, C. S., & Shirmohammadi, D. (1995) · IEEE Transactions on Power Systems · doi:10.1109/59.387902 · Cited by 854
Impact of Network Reconfiguration on Loss Allocation of Radial Distribution Systems
Savier, J. S., & Das, D. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2007.905370 · Cited by 563 · cited 1×
“The base year data are available in [37].”
Decision making under uncertainty in energy systems: State of the art
Soroudi, A., & Amraee, T. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.08.039 · Cited by 550 · cited 1×
“A new standard classification of uncertainty modeling techniques for decision making process was proposed in [18].”
MethodDistribution system power flow analysis-a rigid approach
Chen, T.-H., Chen, M.-S., Hwang, K.-J., Kotas, P., & Chebli, E. A. (1991) · IEEE Transactions on Power Delivery · doi:10.1109/61.85860 · Cited by 495 · cited 1×
“However, based on the available standards for service quality, satisfactory voltage levels should be preserved [22].”
BackgroundEffect of Load Models in Distributed Generation Planning
Singh, D., Misra, R. K., & Singh, D. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.907582 · Cited by 434 · cited 1×
“DERs are strategically located and operated in these systems to postpone the system upgrades, improve the voltage profile, reduce the loss cost, and to enhance the system reliability [2].”
Background
Cited by
Ghadimi, N., Akbarimajd, A., Shayeghi, H., & Abedinia, O. (2018) · Energy · doi:10.1016/j.energy.2018.07.088 · Cited by 257
Self-citationGorjian, A., Eskandari, M., & Moradi, M. H. (2023) · Energies · doi:10.3390/en16052502 · Cited by 19
Metadata
- Authors
- Gheydi, M., Nouri, A., & Ghadimi, N.
- Venue
- IEEE Systems Journal
- Published
- 2018-09
- Volume
- 12
- Issue
- 3
- Pages
- 2782-2790
- ISSN
- 1932-8184 (ISSN-L)
- 1937-9234
- 2373-7816
- OpenAlex
- W2563045807
- Cited by
- 160
- References
- 27
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Planning in Microgrids With Conservation of Voltage Reduction. https://app.cochat.ai/papers/10.1109/jsyst.2016.2633512
- The paper
- Gheydi, M., Nouri, A., & Ghadimi, N. (2018). Planning in Microgrids With Conservation of Voltage Reduction. IEEE Systems Journal. https://doi.org/10.1109/jsyst.2016.2633512
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.