Deep Autoencoder-Based Anomaly Detection of Electricity Theft Cyberattacks in Smart Grids
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Designing an electricity theft cyberattack detector for the advanced metering infrastructures (AMIs) is challenging due to the limited availability of electricity theft datasets (i.e., malicious datasets). Anomaly detectors, which are trained solely on honest customers’ energy consumption profiles (i.e., benign datasets), could potentially overcome this challenge. Unfortunately, existing anomaly detectors in AMIs present shallow architectures and are incapable of capturing the temporal correlations as well as the sophisticated patterns present in the electricity consumption data, which impact their detection performance negatively. This article proposes the adoption of deep (stacked) autoencoders with a long-short-term-memory (LSTM)-based sequence-to-sequence (seq2seq) structure. The depth of the autoencoders’ structure helps capture the sophisticated patterns of the data and the seq2seq LSTM model enables exploitation of the time-series nature of data. We investigate the performance of simple autoencoder, variational autoencoder, and autoencoder with attention (AEA), in which improved detection performance is observed when seq2seq structures are adopted compared to fully connected ones. Based on the simulation results, the AEA detector offers an enhancement of$4\!-\!21\%$and$4\!-\!13\%$in terms of detection rate and false alarm rate, respectively, compared to existing state-of-the-art detectors
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Generating Sentences from a Continuous Space
Bowman, S. R., Vilnis, L., Vinyals, O., Dai, A., Jozefowicz, R., & Bengio, S. (2016) · Proceedings of The 20th SIGNLL Conference on Computational Natural Language Learning · doi:10.18653/v1/k16-1002 · Cited by 2,061 · cited 1×
“Originally, LSTM-VAEs were used to generate data for language modeling applications [33].”
MethodUnsupervised Learning of Video Representations using LSTMs
Srivastava, N., Mansimov, E., & Salakhutdinov, R. (2015) · arXiv · doi:10.48550/arxiv.1502.04681 · Cited by 1,861 · cited 1×
“LSTM encoder and the second one is a deep LSTM decoder [29], [30].”
BackgroundSemi-supervised Sequence Learning
Dai, A. M., & Le, Q. V. (2015) · arXiv · doi:10.48550/arxiv.1511.01432 · Cited by 994 · cited 1×
“A deep LSTM-SAE model consists of two LSTM-RNNs, where the first LSTM-RNN is a deep LSTM encoder and the second one is a deep LSTM decoder [29], [30].”
Wide and Deep Convolutional Neural Networks for Electricity-Theft Detection to Secure Smart Grids
Zheng, Z., Yang, Y., Niu, X., Dai, H.-N., & Zhou, Y. (2018) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2785963 · Cited by 788 · cited 1×
“The first dataset is acquired from the State Grid Corporation of China (SGCC) [23]; it has labeled benign and malicious daily energy consumption readings of real customers.”
BackgroundElectricity Theft Detection in AMI Using Customers’ Consumption Patterns
Jokar, P., Arianpoo, N., & Leung, V. C. M. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2425222 · Cited by 761 · cited 12×
“The SVM, Naïve Bayes, and feed forward-based detectors are static classifiers that are incapable of capturing the time-series nature of the energy data.”
BackgroundMethodInfluentialDecision Tree and SVM-Based Data Analytics for Theft Detection in Smart Grid
Jindal, A., Dua, A., Kaur, K., Singh, M., Kumar, N., & Mishra, S. (2016) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2016.2543145 · Cited by 547 · cited 1×
“Additionally, a two-step detector based on decision trees and SVM reports a 92% accuracy score [11], whereas an extreme gradient boosting classifier offers a precision score of 97% [12].”
MethodShort-term offshore wind speed forecast by seasonal ARIMA - A comparison against GRU and LSTM
Liu, X., Lin, Z., & Feng, Z. (2021) · Energy · doi:10.1016/j.energy.2021.120492 · Cited by 461 · cited 1×
“Although gated recurrent units (GRU) might offer faster training time using less number of gates, LSTM tends to provide better accuracy than GRU at the expense of training time [27], [28].”
BackgroundPunmiya, R., & Choe, S. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2019.2892595 · Cited by 410 · cited 1×
“Since smart meters provide lots of energy consumption data, machine learning models are proposed to identify electricity thefts [6], [7].”
BackgroundElectricity Theft Detection in Smart Grid Systems: A CNN-LSTM Based Approach
Hasan, M. N., Toma, R. N., Nahid, A.-A., Islam, M. M. M., & Kim, J.-M. (2019) · Energies · doi:10.3390/en12173310 · Cited by 379 · cited 1×
“Deep machine learning-based classifiers including feed forward neural networks [13], recurrent neural networks (RNNs) [14], and vector embeddings [15] report 92–95% in DR. Hybrid detectors based on convolutional neural networks (CNNs) and RNN variations exhibit an accuracy score of 89% [16], [17].”
BackgroundElectricity Theft Detection in Power Grids with Deep Learning and Random Forests
Li, S., Han, Y., Yao, X., Yingchen, S., Wang, J., & Zhao, Q. (2019) · Journal of Electrical and Computer Engineering · doi:10.1155/2019/4136874 · Cited by 216 · cited 1×
“AdaBoost [9] and random forests [10] provide an accuracy of 80% and F1-score of 81%, respectively.”
Background
Cited by
Distributed Anomaly Detection in Smart Grids: A Federated Learning-Based Approach
Jithish, J., Alangot, B., Mahalingam, N., & Yeo, K. S. (2023) · IEEE Access · doi:10.1109/access.2023.3237554 · Cited by 251
“Takkidin et al. [63] designed an attack detector for electricity thefts.”
BackgroundMazhar, T., Irfan, H. M., Khan, S., Haq, I., Ullah, I., Iqbal, M., & Hamam, H. (2023) · Future Internet · doi:10.3390/fi15020083 · Cited by 201
“Strategies to protect against or avoid the occurrence Investigating the effects of combined cyber and physical attacks on smart grids. of cyberattacks. malware, Multiple cyberattacks have been [10] DoS/DDoS attacks and metering”
BackgroundMethodInfluentialAhsan, F., Dana, N. H., Sarker, S. K., Li, L., Muyeen, S. M., Ali, M. F., Tasneem, Z., Hasan, M. M., Abhi, S. H., Islam, M. R., et al. (2023) · Protection and Control of Modern Power Systems · doi:10.1186/s41601-023-00319-5 · Cited by 191
“Deep Autoencoder [79] Deep Autoencoder consists of two deep belief networks that are symmetrical Anomaly detection of electricity theft cyberattacks”
BackgroundArtificial intelligence and physics-based anomaly detection in the smart grid: A survey
Gaggero, G. B., Girdinio, P., & Marchese, M. (2025) · IEEE Access · doi:10.1109/access.2025.3537410 · Cited by 67
Metadata
- Authors
- Takiddin, A., Ismail, M., Zafar, U., & Serpedin, E.
- Venue
- IEEE Systems Journal
- Published
- 2022-09
- Volume
- 16
- Issue
- 3
- Pages
- 4106-4117
- ISSN
- 1932-8184 (ISSN-L)
- 1937-9234
- 2373-7816
- OpenAlex
- W4206151196
- Cited by
- 213
- References
- 20
- FWCI
- 12.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.