The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
A Compact, Low-Profile Fractal Antenna for Wearable On-Body WBAN Applications
Abstract
A compact and low-profile wearable antenna is presented for on-body wireless body area network (WBAN) applications. The proposed triangular patch antenna is designed using low-cost widely available vinyl polymer-based flexible substrate. The final antenna topology is obtained by the combination of the Koch fractal geometry, meandering slits, and defected ground structure, to achieve a novel hybrid structure with compact footprint, good structural conformability, and enhanced impedance bandwidth (BW) to operate in the Industrial, Scientific, and Medical band with center frequency at 2.45 GHz. The fabricated prototype of the antenna has shown a good agreement between numerical and experimental results. In comparison to state-of-the-art prototypes, our design has more compact form factor of 0.318λo × 0.318λo × 0.004λo, along with 7.75% impedance BW, a peak gain of 2.06 dBi, and overall radiated efficiency of 75%. For the assessment of a specific absorption rate (SAR) performance of our design, it is tested on realistic heterogeneous HUGO voxel model. Both numerical and experimental investigations revealed extremely good robustness to both human body loading and structural deformation, making it an ideal candidate for flexible and body-worn devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Compact, Low-Profile Metasurface-Enabled Antenna for Wearable Medical Body-Area Network Devices
Jiang, Z. H., Brocker, D. E., Sieber, P. E., & Werner, D. H. (2014) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2014.2327650 · Cited by 365
Compact Half Diamond Dual-Band Textile HMSIW On-Body Antenna
Agneessens, S., & Rogier, H. (2014) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2014.2308526 · Cited by 222
Design of a Broadband All-Textile Slotted PIFA
Soh, P. J., Vandenbosch, G. A. E., Ooi, S. L., & Rais, N. H. M. (2012) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2011.2167950 · Cited by 210
High-resolution human anatomy models for advanced electromagnetic field computations
Gjonaj, E., Bartsch, M. S., Clemens, M., et al. (2002) · IEEE Transactions on Magnetics · doi:10.1109/20.996096 · Cited by 75
Medical Body Area Networks: Opportunities, challenges and practices
Fang, G., Dutkiewicz, E., Huq, M. A., Vesilo, R., & Yang, Y. (2011) · doi:10.1109/iscit.2011.6089699 · Cited by 28
Cited by
Kirtania, S. G., Elger, A. W., Hasan, M. R., Wisniewska, A., Sekhar, K., Karacolak, T., & Sekhar, P. K. (2020) · Micromachines · doi:10.3390/mi11090847 · Cited by 276
Riaz, A., Khan, S., & Arslan, T. (2023) · Micromachines · doi:10.3390/mi14030610 · Cited by 37
Metadata
- Authors
- Arif, A., Zubair, M., Ali, M., Khan, M. U., & Mehmood, M. Q.
- Venue
- IEEE Antennas and Wireless Propagation Letters
- Published
- 2019-05
- Volume
- 18
- Issue
- 5
- Pages
- 981-985
- ISSN
- 1536-1225 (ISSN-L)
- 1548-5757
- OpenAlex
- W2932524051
- Cited by
- 291
- References
- 5
- FWCI
- 28.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.