Printable and Stretchable Conductive Wirings Comprising Silver Flakes and Elastomers
The DOI matches its Crossref record.
Abstract
Smart textiles such as wearable computers and health-care sensors on everyday clothing will be realized likely in the near future. Here, we report that highly electrical conductors were fabricated by filling half of the volume of a polyurethane elastomer with microsized silver flakes under a low temperature of 70°C. Given the high affinity of polyurethane with silver flakes and substrates, high conductivity was maintained on polyurethane substrates stretched up to a strain of 600% and on folded cellulosic substrates. Illumination of a light-emitting diode was also successful with the stretched wirings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Printable elastic conductors with a high conductivity for electronic textile applications
Matsuhisa, N., Kaltenbrunner, M., Yokota, T., Jinno, H., Kuribara, K., Sekitani, T., & Someya, T. (2015) · Nature Communications · doi:10.1038/ncomms8461 · Cited by 869
Smart fabric sensors and e-textile technologies: a review
Castano, L. M., & Flatau, A. B. (2014) · Smart Materials and Structures · doi:10.1088/0964-1726/23/5/053001 · Cited by 793
Printable elastic conductors by in situ formation of silver nanoparticles from silver flakes
Matsuhisa, N., Inoue, D., Zalar, P., Jin, H., Matsuba, Y., Itoh, A., Yokota, T., Hashizume, D., & Someya, T. (2017) · Nature Materials · doi:10.1038/nmat4904 · Cited by 750
Stretchable and self-healing polymers and devices for electronic skin
Benight, S. J., Wang, C., Tok, J. B. H., & Bao, Z. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2013.08.001 · Cited by 617
Materials and structural designs of stretchable conductors
Matsuhisa, N., Chen, X., Bao, Z., & Someya, T. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00814k · Cited by 566
Liang, J., Tong, K., & Pei, Q. (2016) · Advanced Materials · doi:10.1002/adma.201600772 · Cited by 535
Kong, J.-H., Jang, N.-S., Kim, S.-H., & Kim, J.-M. (2014) · Carbon · doi:10.1016/j.carbon.2014.05.022 · Cited by 333
Li, M., Li, H., Zhong, W., Zhao, Q., & Wang, D. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am4053305 · Cited by 253
Conductive Elastomers for Stretchable Electronics, Sensors and Energy Harvesters
Noh, J.-S. (2016) · Polymers · doi:10.3390/polym8040123 · Cited by 136
“8 ˆ 10 ́4 Ω ̈ cm and high stretchability up to 600% [62].”
Guo, W., Zheng, P., Huang, X., Zhuo, H., Wu, Y., Yin, Z., Li, Z., & Wu, H. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b21836 · Cited by 125
Metadata
- Authors
- Araki, T., Nogi, M., Suganuma, K., Kogure, M., & Kirihara, O.
- Venue
- IEEE Electron Device Letters
- Published
- 2011-10
- Volume
- 32
- Issue
- 10
- Pages
- 1424-1426
- ISSN
- 0741-3106 (ISSN-L)
- 1558-0563
- OpenAlex
- W2164432027
- Cited by
- 114
- References
- 0
- FWCI
- 4.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.