The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Stretchable Conductive Polypyrrole/Polyurethane (PPy/PU) Strain Sensor with Netlike Microcracks for Human Breath Detection
Abstract
The development of wearable electronics that can monitor human physiological information demands specially structured materials with excellent stretchability and electrical conductivity. In this study, a new stretchable conductive polypyrrole/polyurethane (PPy/PU) elastomer was designed and prepared by surface diffusion and in situ polymerization of PPy inside and on porous PU substrates. The structures allowed the formation of netlike microcracks under stretching. The netlike microcrack structures make possible the reversible changes in the electrical resistance of PPy/PU elastomers under stretching and releasing cycles. The variations in morphology and chemical structures, stretchability, and conductivity as well as the sensitivity of resistance change under stretching cycles were investigated. The mechanism of reversible conductivity of the PPy/PU elastomer was proposed. This property was then used to construct a waistband-like human breath detector. The results demonstrated its potential as a strain sensor for human health care applications by showing reversible resistance changes in the repeated stretching and contracting motion when human breathes in and out.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A flexible and highly sensitive strain-gauge sensor using reversible interlocking of nanofibres
Pang, C., Lee, G.-Y., Kim, T.-I., Kim, S. M., Kim, H. N., Ahn, S.-H., & Suh, K.-Y. (2012) · Nature Materials · doi:10.1038/nmat3380 · Cited by 1,695
Cited by
Stretchable, Skin-Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review
Amjadi, M., Kyung, K., Park, I., & Sitti, M. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504755 · Cited by 3,202
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Cai, G., Wang, J., Qian, K., Chen, J., Li, S., & Lee, P. S. (2017) · Advanced Science · doi:10.1002/advs.201600190 · Cited by 921
Electrically conductive polymer composites for smart flexible strain sensors: a critical review
Liu, H., Li, Q., Zhang, S., Yin, R., Liu, X., He, Y., Dai, K., Shan, C., Guo, J., Liu, C., et al. (2018) · Journal of Materials Chemistry C · doi:10.1039/c8tc04079f · Cited by 709
Stretchable and tough conductive hydrogels for flexible pressure and strain sensors
Wang, Z., Cong, Y., & Fu, J. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb02570g · Cited by 607
Metadata
- Authors
- Li, M., Li, H., Zhong, W., Zhao, Q., & Wang, D.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-01-06
- Volume
- 6
- Issue
- 2
- Pages
- 1313-1319
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2325333929
- Cited by
- 253
- References
- 1
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stretchable Conductive Polypyrrole/Polyurethane (PPy/PU) Strain Sensor with Netlike Microcracks for Human Breath Detection. https://app.cochat.ai/papers/10.1021/am4053305
- The paper
- Li, M., Li, H., Zhong, W., Zhao, Q., & Wang, D. (2014). Stretchable Conductive Polypyrrole/Polyurethane (PPy/PU) Strain Sensor with Netlike Microcracks for Human Breath Detection. ACS Applied Materials & Interfaces. https://doi.org/10.1021/am4053305
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.