Dielectric-Modulated Impact-Ionization MOS Transistor as a Label-Free Biosensor
Open accessThe DOI matches its Crossref record; 13 of the 14 references it cites were found in a registry or an index.
Abstract
In this letter, we propose a dielectric-modulated impact-ionization MOS (DIMOS) transistor-based sensor for application in label-free detection of biomolecules. Numerous reports exist on the experimental demonstration of nanogap-embedded field effect transistor-based biosensors, but an impact-ionization MOS (I-MOS)-based biosensor has not been reported previously. The concept of a dielectric-modulated I-MOS-based biosensor is presented in this letter based on technology computer-aided design simulation study. The results show a high sensitivity to the presence of biomolecules even at small channel lengths. In addition, a low variability of the sensitivity to the charges on the biomolecule is observed. The high sensitivity, dominance of dielectric-modulation effects, and operation at even small channel lengths make the DIMOS biosensor a promising alternative for CMOS-based sensor applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“As transistors shrink to the nanometer scale, traditional planar FET devices will suffer severe short-channel effects, resulting in increased power consumption and decreased sensitivity of the DMFET-based biosensors [11].”
From A Vertically Stacked Nanosheet Gate-All-Around FET for Biosensing Application (2021) · cites this paper as [11]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A dielectric-modulated field-effect transistor for biosensing
Im, H., Huang, X.-J., Gu, B., & Choi, Y.-K. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.180 · Cited by 635
Impact Ionization MOS (I-MOS)—Part I: Device and Circuit Simulations
Gopalakrishnan, K., Griffin, P. B., & Plummer, J. D. (2005) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2004.841344 · Cited by 311
Novel Dielectric-Modulated Field-Effect Transistor for
Kim, C., Jung, C., Park, H. G., & Choi, Y. (2008) · Cited by 213
The development and application of FET-based biosensors
Bergveld, P. (1986) · Biosensors · doi:10.1016/0265-928x(86)85010-6 · Cited by 207 · cited 1×
“THE application of field effect transistor (FET) as a biosensor for label-free detection of charged biomolecules has seen significant usage [1]–[3].”
BackgroundAnalytical Modeling of a Nanogap-Embedded FET for Application as a Biosensor
Choi, J.-M., Han, J.-W., Choi, S.-J., & Choi, Y.-K. (2010) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2010.2076152 · Cited by 175
Nanogap Field‐Effect Transistor Biosensors for Electrical Detection of Avian Influenza
Gu, B., Park, T. J., Ahn, J., Huang, X., Lee, S. Y., & Choi, Y. (2009) · Small · doi:10.1002/smll.200900450 · Cited by 134
Label-free DNA detection with a nanogap embedded complementary metal oxide semiconductor
Kim, C.-H., Jung, C., Lee, K.-B., Park, H. G., & Choi, Y.-K. (2011) · Nanotechnology · doi:10.1088/0957-4484/22/13/135502 · Cited by 103
Guan, W., Duan, X., & Reed, M. A. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.07.061 · Cited by 83
100-nm n-/p-channel I-MOS using a novel self-aligned structure
Choi, W. Y., Song, J. Y., Lee, J. D., Park, Y. J., & Park, B. (2005) · IEEE Electron Device Letters · doi:10.1109/led.2005.844695 · Cited by 78
Wenga, G., Jacques, E., Salaün, A.-C., Rogel, R., Pichon, L., & Geneste, F. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.07.001 · Cited by 65
Research works printed but not linked: 3
- [10] K. Gopalakrishnan, R. Woo, C. Jungemann, P.B. Griffin, and J.D. Plummer, "Impact ionization MOS (I-MOS)-Part II: experimental results," IEEE Trans. Electron Devices , vol. 52, no. 1, pp. 77-84, Jan. 2005. - · doi:10.1109/ted.2004.841345(410
- [13] F. Mayer, C. Le Royer, G. Le Carval, C. Tabone, L. Clavelier, and S. Deleonibus, "Co-integration of 2 mV/dec subthreshold slope impact ionization MOS (I-MOS) with CMOS." Proceedings of the 36th European Solid-State Device Research Conference, ESSDERC 2006, Sept. 2006, pp. 303-306. -
- [16] 3. ATLAS User's Manual: Device Simulation Software , Silvaco Int., Santa Clara, CA, USA.
Cited by
Items 101–163 of 163
Vedvrat, Shukla, M. M., & Sachan, R. K. (2025) · Physics of the Solid State · doi:10.1134/s1063783425602607 · Cited by 7
Design and sensitivity analysis of GAA nanowire dopingless FET based label free biosensor
Solay, L. R., Kumar, N., Singh, S., Amin, S. I., Yuvaraja, S., & Anand, S. (2024) · Physica Scripta · doi:10.1088/1402-4896/ad4926 · Cited by 7
Kanungo, S., Rahaman, H., & Chattopadhyay, S. (2015) · International Conference on Computers and Devices for Communication · doi:10.1109/codec.2015.7893189 · Cited by 7
“In the past decade, the Dielectrically Modulated Field Effect Transistors (DMFETs) have emerged as the potential candidates for label-free bio-sensing applications [1-6].”
BackgroundOuarghi, M., Dibi, Z., & Hedjazi, N. (2018) · Journal of Computational Electronics · doi:10.1007/s10825-018-1228-3 · Cited by 6
Singh, J., & Singh, S. K. (2024) · Materials Science and Engineering B · doi:10.1016/j.mseb.2024.117688 · Cited by 7
Tamersit, K., Kouzou, A., Rodríguez, J., & Abdelrahem, M. (2025) · Micromachines · doi:10.3390/mi16060690 · Cited by 6
“…such as the on-state current, off-state current, current ratio, subthreshold swing, conductance, and transconductance, can also be used to monitor bio-events, in addition to the shift in threshold voltage, which is the commonly used biometric in dielectric modulated FET-based biosensor [20–28].”
Ranjith Kumar, T., & Priya, G. L. (2025) · Scientific Reports · doi:10.1038/s41598-025-08892-5 · Cited by 5
Comparative Analysis of FinFET and NSFET Architectures for Label-Free Biosensing Applications
Gowthami, U., Rao, T. S., Tata, S., Srilakshmi, K., & Prakash, M. D. (2026) · Silicon · doi:10.1007/s12633-026-03644-0 · Cited by 6
Endurance Behavior of Z-Shaped Charge Plasma Tunnel FET for Biosensing Application
Singh, R., Naugarhiya, A., & Mishra, G. P. (2023) · Journal of Circuits Systems and Computers · doi:10.1142/s0218126624500269 · Cited by 5
Panda, S., & Dash, S. (2024) · ECS Journal of Solid State Science and Technology · doi:10.1149/2162-8777/ad6a89 · Cited by 5
Babu, K. M. C., & Goel, E. (2024) · Physica Scripta · doi:10.1088/1402-4896/ada40c · Cited by 5
Kannan, N., & Kumar, M. J. (2014) · IEEE International Conference on Emerging Electronics (ICEE) · doi:10.1109/icemelec.2014.7151213 · Cited by 5
“Significantly increased sensitivities have been reported with such devices [7], [8], and [11].”
BackgroundSelf-citationInfluence of Channel Silicon Thickness and Biological Material Permittivity on nTFET Biosensor
Macambira, C. N., Agopian, P. G. D., & Martino, J. A. (2018) · Symposium on Microelectronics Technology and Devices · doi:10.1109/sbmicro.2018.8511580 · Cited by 5
“, the use of biosensors based on field effect transistor (FET) [2]–[5].”
BackgroundDielectrically Modulated Bio-FET for Label-Free Detection of Bio-molecules
Bhattacharyya, A., Chanda, M., & De, D. (2021) · Studies in systems, decision and control · doi:10.1007/978-981-15-9612-4_8 · Cited by 5
Saha, A., Singh, S., Dhar, R. S., Ghosh, K., Seteikin, A., Banerjee, A., & Samusev, I. (2025) · Biosensors · doi:10.3390/bios15090613 · Cited by 4
“Certain biomolecules possess a charge, while others remain neutral [15–19].”
Tamersit, K., Kouzou, A., Rodríguez, J., & Abdelrahem, M. (2024) · Nanomaterials · doi:10.3390/nano14242038 · Cited by 4
Malvika, M., Talukdar, J., Choudhuri, B., & Mummaneni, K. (2024) · Physica Scripta · doi:10.1088/1402-4896/ad732f · Cited by 4
Impact of back-gate voltage on sensing metric of dielectric modulated Tunnel FET biosensor
Dwivedi, P., Kumar, A., Sengar, B. S., Garg, V., & Singh, R. K. (2020) · International Conference on Emerging Frontiers in Electrical and Electronic Technologies (ICEFEET) · doi:10.1109/icefeet49149.2020.9187002 · Cited by 4
“ion-sensitive FET, dielectric modulated FET, Junctionless FET, impact ionization, and tunnel FET (TFET) based biosensor[1, 3-9].”
BackgroundInvestigation of Structural Parameter Variation on Extended Gate TFET for Bio-Sensor Applications
Mukherjee, S., Chakraborty, S., Diwakar, D., Laha, A., Ganguly, U., & Ganguly, S. (2020) · Proceeding of the Electrical Engineering Computer Science and Informatics · doi:10.23919/eecsi50503.2020.9251884 · Cited by 4
Hanif, M., Zahoor, F., Alzahrani, A., Duffy, R., May, Z. B., & Bashir, F. I. (2025) · Materials Science in Semiconductor Processing · doi:10.1016/j.mssp.2025.110274 · Cited by 3
Kannan, N., & Kumar, M. J. (2017) · Superlattices and Microstructures · doi:10.1016/j.spmi.2017.03.004 · Cited by 3
Self-citationTamersit, K., & Djeffal, F. (2019) · IEEE International Conference on Design & Test of Integrated Micro & Nano-Systems (DTS) · doi:10.1109/dtss.2019.8915042 · Cited by 3
Gayen, S., Tewari, S., & Chattopadhyay, A. (2020) · IETE Technical Review · doi:10.1080/02564602.2020.1747951 · Cited by 3
Phosphorene-based intelligent nanosensor for wearable electronics applications
Ramesh, R., Bhattacharyya, A., Pon, A., Nirmal, D., & Ajayan, J. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-820783-3.00012-9 · Cited by 3
Mamidala, J. K., Vishnoi, R., & Pandey, P. (2016) · Wiley eBooks · doi:10.1002/9781119246312.ch3 · Cited by 3
Nanotube TFET Biosensor with High-Frequency FOMs as Sensing Parameter
Gedam, A., Acharya, B., & Mishra, G. P. (2024) · Journal of Circuits Systems and Computers · doi:10.1142/s0218126624502189 · Cited by 3
Ge Pocket-Based Dual Gate Tunnel FET: A Label-Free Biosensor
Wani, M. S., Khan, A., Alharbi, A. G., Aldkeelalah, S. S., & Loan, S. A. (2025) · ACS Omega · doi:10.1021/acsomega.5c02855 · Cited by 3
Macambira, C. N., Agopian, P. G. D., & Martino, J. A. (2021) · ECS Journal of Solid State Science and Technology · doi:10.1149/2162-8777/ac0ecb · Cited by 3
Bhattacherjee, S., Dhar, P., & Roy, S. (2023) · Current Materials Science · doi:10.2174/0126661454274311231011070702 · Cited by 2
A Virtually Doped Hetero Z-Shaped Charge Plasma TFET Based Label Free Biosensor
Singh, R., Ghai, V., Naugarhiya, A., & Mishra, G. P. (2025) · Sensing and Imaging · doi:10.1007/s11220-025-00621-6 · Cited by 2
Wani, M. S., Alkhammash, H. I., Shiblee, M., & Loan, S. A. (2023) · doi:10.1109/icm60448.2023.10378940 · Cited by 2
Lee, C., Lin, W., & Lin, Y.-T. (2015) · IEEE Electron Device Letters · doi:10.1109/led.2015.2490741 · Cited by 2
“AS GATE length of the metal–oxide–semiconductor fieldeffect transistor (MOSFET) is reduced for obtaining better radio-frequency (RF) performance, high electric field [1], [2] can lead to the RF impact ionization effect at the drain terminal.”
BackgroundChakraborty, A., Sarkar, A., & Sarkar, A. (2021) · Elsevier eBooks · doi:10.1016/b978-0-323-85172-5.00008-3 · Cited by 2
Baruah, K., & Baishya, S. (2022) · International Conference on Electrical, Computer, Communications and Mechatronics Engineering (ICECCME) · doi:10.1109/iceccme55909.2022.9988358 · Cited by 2
“Instead, they use the analytes' intrinsic physical characteristics, such as their molecular weight, charge, electrical impedance, size, dielectric constant (permittivity), or refractive index, to determine whether or not they are present in a sample [5-8].”
BackgroundLabel-Free Biosensing using Dielectric Modulated GaAs1-x Sbx FinFET under Dry/Wet Environment
Dixit, A., Samajdar, D. P., & Bagga, N. (2021) · IEEE India Conference · doi:10.1109/indicon52576.2021.9691731 · Cited by 1
Kumar, P., Vinod, A., Jena, B., Arivarasi, A., & Bahadur, J. (2024) · International Journal of Numerical Modelling Electronic Networks Devices and Fields · doi:10.1002/jnm.3291 · Cited by 1
Performance Evaluation of Ge-Source Dielectrically Modulated TFET
Raghav, P., Bharti, M., & Paras, N. (2024) · International Conference on Electronics, Communication and Signal Processing (ICECSP) · doi:10.1109/icecsp61809.2024.10698660 · Cited by 1
“In contrast, label-free biosensors operate without the need for added labels, relying instead on inherent Physical properties of analytes for detection, like molecular weight, charge, or refractive index [4-7].”
BackgroundA Novel n+ Pocket Doped L-Shaped Channel TFET for Biosensing Applications
Barwa, D., Khanna, D., Parihar, H., & Kale, S. (2025) · ECS Journal of Solid State Science and Technology · doi:10.1149/2162-8777/adccf8 · Cited by 1
Tamersit, K., Bourouba, H., & Kouzou, A. (2025) · International Conference on Power Electronics and their Applications (ICPEA) · doi:10.1109/icpea68903.2025.11453006 · Cited by 1
“However, most reported designs rely on nanogaps beneath the gate electrode to host biomolecules, a method that introduces uncertainty in molecular binding uniformity and poses significant fabrication challenges due to the difficulty of nanoscale etching [10]-[15].”
Double gate impact ionization MOS transistor: Proposal and investigation
Yang, Z., Zhang, Y., Yang, Y., & Yu, N. (2017) · Superlattices and Microstructures · doi:10.1016/j.spmi.2017.01.015 · Cited by 1
Soni, D., Behera, A. K., Sharma, D., Aslam, M., & Yadav, S. (2019) · Smart innovation, systems and technologies · doi:10.1007/978-981-13-8406-6_16 · Cited by 1
Optimization of low frequency noise for dielectric modulated TFET for bio sensing applications
Bhattacherjee, S., Roy, S., Chakroborty, G., & Ray, U. (2021) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1797/1/012025 · Cited by 1
Sahay, S., & Kumar, M. J. (2019) · Wiley eBooks · doi:10.1002/9781119523543.ch10 · Cited by 1
Self-citationA Dynamic Concentration-Dependent Analytical I ,– V Model for LG-GFET Biosensor
Wu, Y., Xu, T., Jiang, K., Lv, D., Shi, Y., Tang, H. J., Zhao, C., Yu, Y., Liu, H., Xu, Y., et al. (2023) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2023.3268139 · Cited by 1
“In detail, it is mainly used for qualitative and quantitative analysis of biochemical conditions in clinical medical diagnosis and biological science research [9], [10].”
BackgroundTamersit, K., & Bourouba, H. (2024) · Complexity in Engineering (COMPENG) · doi:10.1109/compeng60905.2024.10741466 · Cited by 1
Joshi, A. (2022) · doi:10.36227/techrxiv.19622469 · Cited by 1
Joshi, A. M. (2022) · doi:10.36227/techrxiv.19622469.v1 · Cited by 2
Impact of Asymmetric Spacer on the Performance of Dielectric Modulated TFET Biosensor
Bhattacherjee, S. (2021) · Lecture notes in bioengineering · doi:10.1007/978-981-33-6915-3_10
Estudo dos transistores de tunelamento por efeito de campo como biossensores.
Macambira, C. N. (2021) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.3.2021.tde-04032022-085035
APartially Gated Regenerative Feedback Device for Ultra-High Sensitivity Biosensing Applications
Kalra, S., Kannan, N., & Kumar, M. J. (2024) · IEEE International Conference on Nanotechnology (IEEE-NANO) · doi:10.1109/nano61778.2024.10628630
“Consequently, in the drive to increase detection sensitivity, steep subthreshold slope FETs, namely Impact Ionization MOSFET (I-MOS) [10], [11] and Tunnel Field Effect Transistor (TFET) [12]-[13] have been explored for biosensing applications [14]-[19].”
BackgroundSelf-citationOn Peculiar Sensitivity Trends of N-Channel Dielectric Modulated FET Biosensors
Kalra, S. (2024) · IEEE International Conference on Nanotechnology (IEEE-NANO) · doi:10.1109/nano61778.2024.10628798
“These include double gate nanogap DMFET [10], silicon nanotube DMFET [13], induced nanowire DMFET [14], vertical nanogap DMFET [15], DM-tunnel FET [16], Schottky barrier DMFET [17], DM-IMOS [18], DM-TCCT [19], and hetero material gate DMFET.”
MethodBhattacherjee, S., Barman, A., & Dutta, T. (2024) · International Conference on Computational Intelligence for Green and Sustainable Technologies (ICCIGST) · doi:10.1109/iccigst60741.2024.10717473
“In Kannan et.al., [4], the impact-ionization is applied to sense the biomolecules where high sensitivity, as well as low variability of the sensitivity at small channel lengths, is observed on the biomolecules.”
BackgroundAlGan/GaN Based Dual-Cavity Structure for DNA Detection
Ravikumar, M., & Madheswaran, M. (2024) · Journal of Nanoelectronics and Optoelectronics · doi:10.1166/jno.2024.3682
Performance investigation of Nano-wire Biosensor using Junction-less Gate-All-Around MOSFET
Verma, V. K., Mishra, A. K., Gupta, T. K., Kumar, A., Gupta, A., & Gupta, A. K. (2024) · International Conference on IoT, Communication and Automation Technology (ICICAT) · doi:10.1109/icicat62666.2024.10922920
“Several approaches based on MOSFET technology have been explored to improve the sensitivity and selectivity for biomolecules, as discussed in [17, 18].”
Sensitivity Analysis of a Polarity-Controlled Tunnel Field-Effect Transistor-based Biosensor
Bind, M. K., Singh, S. V., & Nigam, K. (2025) · doi:10.1109/icsc64553.2025.10968084
Reliability optimization of charge deduction approach employing bio-tunnel FET
Bhattacharyya, A., & Chanda, M. (2025) · Journal of Computational Electronics · doi:10.1007/s10825-025-02409-z
“The choice of this type of metal stack has several benefits [16, 17]: 1.”
Bhattacharyya, A., Maity, S., Satpathy, P., Sultana, R., Debnath, P., & Chanda, M. (2025) · IEEE India Council International Subsections Conference (INDISCON) · doi:10.1109/indiscon66021.2025.11251899
“The choice of this type of metal-stack has several benefits [14]–[15]: 1) A wide variety of functionalized categories of bioanalytes can be conjugated to Gold (Au of work function, φ M1 = 5.1 eV) metal gate including DNA, plasmids, and proteins, and thus, it is mainly appropriate in…”
InfluentialInvestigation of Polarization-based Surrounding Gate Tunnel FET for Biosensor Applications
Guan, Y., Yan, T., Dou, Z., Han, H., Liu, X., Lu, Q., & Chen, H. (2025) · International Conference on Frontiers Technology in Circuits and Systems (FTCS) · doi:10.1109/ftcs68006.2025.11405812
“Label-free biosensing systems utilize the innate physical attributes of intended analytes, such as the charge, dielectric constant, and refractive index, offering multiple advantages [1]-[3].”
Revolutionary Gate Designs : Dual and Triple Gate MOSFETs in Biosensing-A Review
Lakshmi, M., & Rajasekaran, S. (2025) · International Conference on Sustainable Computing and Smart Systems (ICSCSS) · doi:10.1109/icscss64956.2025.11500860
“Electric field has also modulated by changing the charge and dielectric nature of analytes in the neighborhood of the gate region as well as the carrier motion [25, 28].”
Analysis of Si/GaSb Stacked Source Vertical TFET Biosensor for Breast Cancer Detection
Bharali, S., Choudhuri, B., Bhowmick, B., & Dutta, L. (2026) · Sensing and Imaging · doi:10.1007/s11220-026-00841-4
“Air environment is considered when the etched nano gap inside the dielectric is empty, in case of experiment the nano gaps will remain empty [ 25 ].”
Rastogi, R., Tripathi, D. K., & Dubey, S. (2026) · Doklady Physics · doi:10.1134/s1028335826600641
Dhar, P., Bhattacherjee, S., Roy, S., Sardar, T. H., Gourisaria, M. K., & M., A. S. B. (2026) · Scientia Iranica · doi:10.24200/sci.2025.66715.10206
“Numerous FET-based biosensors with various device topologies, such as tunnel FETs [6-12], impact ionization FETs (IMOS) [13], and junctionless FETs [14-19], were proposed in various studies.”
Mahanna, B. M., Amin, M., Jamil, M. S., & Billah, M. M. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.10.15.759373
“…biosensors [14], 9 nm in double-gate junctionless FET (DG-JLFET) nanogap architectures [10], 10 nm in dual-gate transition-metal dichalcogenide FET (TMD-FET) biosensors [15], and 15 nm in dielectric-modulated impact-ionization metal–oxide– semiconductor (DIMOS) transistor biosensors [16].”
Metadata
- Authors
- Kannan, N., & Kumar, M. J.
- Affiliations
- Indian Institute of Technology Delhi (IN)
- Venue
- IEEE Electron Device Letters
- Published
- 2013-12
- Volume
- 34
- Issue
- 12
- Pages
- 1575-1577
- ISSN
- 0741-3106 (ISSN-L)
- 1558-0563
- OpenAlex
- W2137015982
- Semantic Scholar
- 17278eb0835f7362e2299542a28df0fa95cf184b
- Cited by
- 161
- References
- 14
- Citations by year
- 2026: 3 · 2025: 16 · 2024: 25 · 2023: 15 · 2022: 12 · 2021: 22 · 2020: 18 · 2019: 8 · 2018: 12 · 2017: 11 · 2016: 8 · 2015: 10 · 2014: 1
- FWCI
- 3.80
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Locations
- IEEE Electron Device Letters (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advancements in Semiconductor Devices and Circuit Design
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- dielectric modulation, label-free biosensor, biomolecule detection, charge sensitivity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.