The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Real-time imaging using a 4.3-THz quantum cascade laser and a 320 /spl times/ 240 microbolometer focal-plane array
Abstract
We report the use of a ~50-mW peak power 4.3-THz quantum cascade laser (QCL) as an illumination source for real-time imaging with a 320 times 240 element room-temperature microbolometer focal-plane array detector. The QCL is modulated synchronously with the focal-plane array for differential imaging. Signal-to-noise ratios of ~340 are achieved at a 20-frame/s acquisition rate, and the optical noise equivalent power of the detector array at 4.3 THz is estimated to be ~320 pW/radicHz. Both reflection and transmission mode imaging are demonstrated
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Terahertz semiconductor-heterostructure laser
Köhler, R., Tredicucci, A., Beltram, F., Beere, H. E., Linfield, E. H., Davies, A. G., Ritchie, D. A., Iotti, R. C., & Rossi, F. (2002) · Nature · doi:10.1038/417156a · Cited by 2,722
Terahertz pulse imaging in reflection geometry of human skin cancer and skin tissue
Woodward, R. M., Cole, B. E., Wallace, V. P., Pye, R. J., Arnone, D. D., Linfield, E. H., & Pepper, M. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/21/325 · Cited by 702
Integrated THz technology for label-free genetic diagnostics
Nagel, M., Haring Bolivar, P., Brucherseifer, M., Kurz, H., Bosserhoff, A., & Büttner, R. (2002) · Applied Physics Letters · doi:10.1063/1.1428619 · Cited by 543
High-power terahertz quantum-cascade lasers
Williams, B. S., Kumar, S., Hu, Q., & Reno, J. L. (2006) · Electronics Letters · doi:10.1049/el:20063921 · Cited by 273
Self-citationMillimeter-wave, terahertz, and mid-infrared transmissionthrough common clothing
Bjarnason, J. E., Chan, T. L. J., Lee, A. W. M., Celis, M. A., & Brown, E. R. (2004) · Applied Physics Letters · doi:10.1063/1.1771814 · Cited by 195
Self-citation
Cited by
Cutting-edge terahertz technology
Tonouchi, M. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.3 · Cited by 6,301
Terahertz quantum-cascade lasers
Williams, B. S. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.166 · Cited by 1,543
Imaging with terahertz radiation
Chan, W. L., Deibel, J., & Mittleman, D. M. (2007) · Reports on Progress in Physics · doi:10.1088/0034-4885/70/8/r02 · Cited by 965
The 2023 terahertz science and technology roadmap
Leitenstorfer, A., Moskalenko, A. S., Kampfrath, T., Kono, J., Castro-Camus, E., Peng, K., Qureshi, N., Turchinovich, D., Tanaka, K., Markelz, A. G., et al. (2023) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/acbe4c · Cited by 514
Toward real-time terahertz imaging
Guerboukha, H., Nallappan, K., & Skorobogatiy, M. (2018) · Advances in Optics and Photonics · doi:10.1364/aop.10.000843 · Cited by 467
Metadata
- Authors
- Lee, A. W. M., Wil, B. S., Kumar, S., Hu, Q., & Reno, J. L.
- Venue
- IEEE Photonics Technology Letters
- Published
- 2006-07
- Volume
- 18
- Issue
- 13
- Pages
- 1415-1417
- ISSN
- 1041-1135 (ISSN-L)
- OpenAlex
- W2050833092
- Cited by
- 258
- References
- 5
- FWCI
- 13.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.