The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Terahertz pulse imaging in reflection geometry of human skin cancer and skin tissue
Abstract
We demonstrate the application of terahertz pulse imaging (TPI) in reflection geometry for the study of skin tissue and related cancers both in vitro and in vivo. The sensitivity of terahertz radiation to polar molecules, such as water, makes TPI suitable for studying the hydration levels in the skin and the determination of the lateral spread of skin cancer pre-operatively. By studying the terahertz pulse shape in the time domain we have been able to differentiate between diseased and normal tissue for the study of basal cell carcinoma (BCC). Basal cell carcinoma has shown a positive terahertz contrast, and inflammation and scar tissue a negative terahertz contrast compared to normal tissue. In vivo measurements on the stratum corneum have enabled visualization of the stratum corneum-epidermis interface and the study of skin hydration levels. These results demonstrate the potential of terahertz pulse imaging for the study of skin tissue and its related disorders, both in vitro and in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Free-space electro-optic sampling of terahertz beams
Wu, Q., & Zhang, X.-C. (1995) · Applied Physics Letters · doi:10.1063/1.114909 · Cited by 993
Characterization of an optoelectronic terahertz beam system
van Exter, M., & Grischkowsky, D. R. (1990) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/22.60016 · Cited by 486
Shriner, D. L., McCoy, D. K., Goldberg, D. J., & Wagner, R. F. (1998) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(98)70405-0 · Cited by 436
THz reflection spectroscopy of liquid water
Thrane, L., Jacobsen, R. H., Uhd Jepsen, P., & Keiding, S. R. (1995) · Chemical Physics Letters · doi:10.1016/0009-2614(95)00543-d · Cited by 339
Guidelines for the management of basal cell carcinoma
Telfer, Colver, & Bowers (1999) · British Journal of Dermatology · doi:10.1046/j.1365-2133.1999.03033.x · Cited by 339
Topographic Variations in Normal Skin, as Viewed by In Vivo Reflectance Confocal Microscopy
Huzaira, M., Rius, F., Rajadhyaksha, M., Anderson, R. R., & González, S. (2001) · Journal of Investigative Dermatology · doi:10.1046/j.0022-202x.2001.01337.x · Cited by 268
Knüttel, A., & Boehlau-Godau, M. (2000) · Journal of Biomedical Optics · doi:10.1117/1.429972 · Cited by 235
Elbaum, M., Kopf, A. W., Rabinovitz, H. S., Langley, R. G. B., Kamino, H., Mihm, M. C., Sober, A. J., Peck, G. L., Bogdan, A., Gutkowicz-Krusin, D., et al. (2001) · Journal of the American Academy of Dermatology · doi:10.1067/mjd.2001.110395 · Cited by 220
Imaging of the skin with 20-MHz US.
Fornage, B. D., McGavran, M. H., Duvic, M., & Waldron, C. A. (1993) · Radiology · doi:10.1148/radiology.189.1.8372222 · Cited by 176
Applications of terahertz (THz) technology to medical imaging
Arnone, D. D., Ciesla, C. M., Corchia, A., Egusa, S., Pepper, M., Chamberlain, J. M., Bezant, C. D., Linfield, E. H., Clothier, R., & Khammo, N. (1999) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.361037 · Cited by 149
Self-citation
Cited by
Imaging with terahertz radiation
Chan, W. L., Deibel, J., & Mittleman, D. M. (2007) · Reports on Progress in Physics · doi:10.1088/0034-4885/70/8/r02 · Cited by 965
Biomedical applications of terahertz technology
Pickwell, E., & Wallace, V. P. (2006) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/39/17/r01 · Cited by 925
Self-citationTerahertz integrated electronic and hybrid electronic–photonic systems
Sengupta, K., Nagatsuma, T., & Mittleman, D. M. (2018) · Nature Electronics · doi:10.1038/s41928-018-0173-2 · Cited by 711
Terahertz Spectroscopy and Imaging for Defense and Security Applications
Liu, H.-B., Zhong, H., Karpowicz, N., Chen, Y., & Zhang, X.-C. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2007.898903 · Cited by 636
Terahertz Frequency Sensing and Imaging: A Time of Reckoning Future Applications?
Woolard, D. L., Brown, R., Pepper, M., & Kemp, M. (2005) · Proceedings of the IEEE · doi:10.1109/jproc.2005.853539 · Cited by 450
Self-citation
Metadata
- Authors
- Woodward, R. M., Cole, B. E., Wallace, V. P., Pye, R. J., Arnone, D. D., Linfield, E. H., & Pepper, M.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2002-10-16
- Volume
- 47
- Issue
- 21
- Pages
- 3853-3863
- ISSN
- 0031-9155 (ISSN-L)
- OpenAlex
- W2089751226
- Cited by
- 702
- References
- 16
- FWCI
- 8.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Terahertz pulse imaging in reflection geometry of human skin cancer and skin tissue. https://app.cochat.ai/papers/10.1088/0031-9155/47/21/325
- The paper
- Woodward, R. M., Cole, B. E., Wallace, V. P., Pye, R. J., Arnone, D. D., Linfield, E. H., & Pepper, M. (2002). Terahertz pulse imaging in reflection geometry of human skin cancer and skin tissue. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/47/21/325
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.