A Curved-Drilling Approach in Core Decompression of the Femoral Head Osteonecrosis Using a Continuum Manipulator
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In conventional core decompression of osteonecrosis, surgeons cannot successfully reach the whole area of the femoral head due to rigidity of the instruments currently used. To address this issue, we present design and fabrication of a novel steerable drill using a continuum dexterous manipulator (CDM) and two different flexible cutting tools passing through the lumen of the CDM. A set of experiments investigated functionality and efficiency of the curved-drilling approach and the flexible tools on simulated cancellous bone. Geometry of the cutter head, rotational and feed velocity of the tool, and pulling tension of the CDM cables have been identified as the effective curved-drilling parameters. Considering these parameters, we investigated drilling trajectory, contact force, and mass removal for various combinations of feed-velocities (0.05, 0.10, and 0.15 mm/s) and cable tensions (6, 10, 15, and 25 N) with constant rotational speed of 2250 r/min. Results show that: first, pulling tension of the cable is the most dominant parameter affecting the curved-drilling trajectory; and second, the proposed steerable drill is able to achieve 40° bend without buckling. Based on these results we developed a method for planning drill trajectories and successfully verified abilities for S-shape and multiple-branch drilling. The verification experiments were performed on both simulated and human cadaveric bones.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A comparison of similarity measures for use in 2-D-3-D medical image registration
Penney, G. P., Weese, J., Little, J. A., Desmedt, P., Hill, D. L. G., & hawkes, D. J. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730403 · Cited by 782
Cited by
Alambeigi, F., Aghajani Pedram, S., Speyer, J. L., Rosen, J., Iordachita, I., Taylor, R. H., & Armand, M. (2020) · IEEE Transactions on Robotics · doi:10.1109/tro.2019.2946726 · Cited by 48
“, removing osteolytic lesions behind the hip acetabular implant [31] and treatment of osteonecrosis of femoral head [32], [33]) using a custom-designed continuum robot called “orthosnake” (see Fig.”
BackgroundMethodSelf-citationAn assisted telemanipulation approach: combining autonomous grasp planning with haptic cues
Adjigble, M., Marturi, N., Ortenzi, V., & Stolkin, R. (2019) · 2019 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros40897.2019.8968454 · Cited by 19
“For instance, telemanipulation systems are used in the medical field to execute complex surgical procedures [1], [2], and in nuclear settings they help in carrying out complex decommissioning tasks [3].”
BackgroundLocalizing dexterous surgical tools in X-ray for image-based navigation
Gao, C., Unberath, M., Taylor, R., & Armand, M. (2019) · arXiv · doi:10.48550/arxiv.1901.06672 · Cited by 15
“Recent innovations have made CDMs appropriate for use in orthopedic surgery [5,8,1].”
BackgroundMethodSelf-citation
Metadata
- Authors
- Alambeigi, F., Wang, Y., Sefati, S., Gao, C., Murphy, R. J., Iordachita, I., Taylor, R. H., Khanuja, H., & Armand, M.
- Venue
- IEEE Robotics and Automation Letters
- Published
- 2017-07
- Volume
- 2
- Issue
- 3
- Pages
- 1480-1487
- ISSN
- 2377-3766 (ISSN-L)
- 2377-3774
- OpenAlex
- W2588047059
- Cited by
- 87
- References
- 1
- FWCI
- 3.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.