Detection of False Data Injection Attacks in Smart Grid Communication Systems
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The transformation of traditional energy networks to smart grids can assist in revolutionizing the energy industry in terms of reliability, performance and manageability. However, increased connectivity of power grid assets for bidirectional communications presents severe security vulnerabilities. In this letter, we investigate Chi-square detector and cosine similarity matching approaches for attack detection in smart grids where Kalman filter estimation is used to measure any deviation from actual measurements. The cosine similarity matching approach is found to be robust for detecting false data injection attacks as well as other attacks in the smart grids. Once the attack is detected, system can take preventive action and alarm the manager to take preventative action to limit the risk. Numerical results obtained from simulations corroborate our theoretical analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Approach to Linear Filtering and Prediction Problems
Kalman, R. E. (1960) · Journal of Basic Engineering · doi:10.1115/1.3662552 · Cited by 31,751
Cited by
A survey on security control and attack detection for industrial cyber-physical systems
Ding, D., Han, Q.-L., Xiang, Y., Ge, X., & Zhang, X.-M. (2018) · Neurocomputing · doi:10.1016/j.neucom.2017.10.009 · Cited by 944
A Survey on the Detection Algorithms for False Data Injection Attacks in Smart Grids
Musleh, A. S., Chen, G., & Dong, Z. Y. (2020) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2019.2949998 · Cited by 714
A Survey of Cyber Attacks on Cyber Physical Systems: Recent Advances and Challenges
Duo, W., Zhou, M., & Abusorrah, A. (2022) · IEEE/CAA Journal of Automatica Sinica · doi:10.1109/jas.2022.105548 · Cited by 589
Cyber security challenges for IoT-based smart grid networks
Kimani, K., Oduol, V., & Langat, K. (2019) · International Journal of Critical Infrastructure Protection · doi:10.1016/j.ijcip.2019.01.001 · Cited by 500
Cyber-security in smart grid: survey and challenges
Mrabet, Z. E., Kaabouch, N., Ghazi, H. E., & Ghazi, H. E. (2018) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2018.01.015 · Cited by 482
Machine learning driven smart electric power systems: Current trends and new perspectives
Ibrahim, M. S., Dong, W., & Yang, Q. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.115237 · Cited by 435
A survey on attack detection, estimation and control of industrial cyber–physical systems
Zhang, D., Wang, Q.-G., Feng, G., Shi, Y., & Vasilakos, A. V. (2021) · ISA Transactions · doi:10.1016/j.isatra.2021.01.036 · Cited by 317
Detection of False-Data Injection Attacks in Cyber-Physical DC Microgrids
Beg, O. A., Johnson, T. T., & Davoudi, A. (2017) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2656905 · Cited by 297
Mahmoud, M. S., Hamdan, M. M., & Baroudi, U. A. (2019) · Neurocomputing · doi:10.1016/j.neucom.2019.01.099 · Cited by 278
State of the art of cyber-physical systems security: An automatic control perspective
Zacchia Lun, Y., D’Innocenzo, A., Smarra, F., Malavolta, I., & Di Benedetto, M. D. (2019) · Journal of Systems and Software · doi:10.1016/j.jss.2018.12.006 · Cited by 211
“, 2014), and a cosine similarity matching based approach (Rawat and Bajracharya, 2015).”
BackgroundA Systematic Analysis of Enhancing Cyber Security Using Deep Learning for Cyber Physical Systems
Gaba, S., Budhiraja, I., Kumar, V., Martha, S., Khurmi, J., Singh, A., Singh, K. K., Askar, S. S., & Abouhawwash, M. (2024) · IEEE Access · doi:10.1109/access.2023.3349022 · Cited by 62
False data attack models, impact analyses and defense strategies in the electricity grid
Liu, X., & Li, Z. (2017) · The Electricity Journal · doi:10.1016/j.tej.2017.04.001 · Cited by 57
iShare: Blockchain-Based Privacy-Aware Multi-Agent Information Sharing Games for Cybersecurity
Rawat, D. B., Njilla, L., Kwiat, K., & Kamhoua, C. (2018) · 2018 International Conference on Computing, Networking and Communications (ICNC) · doi:10.1109/iccnc.2018.8390264 · Cited by 46
“…patches, and updated operating systems based on Evaluation Assurance Level (EAL) standard for all devices [22], firewalls and IDS/IPS (e.g., [3], [23], [24]), and for sharing the detected cyber-attack information or attack-signature (with possible countermeasures) through iShare framework 3…”
BackgroundSelf-citationFalse Data Injection Impact Analysis In AI-Based Smart Grid
Tufail, S., Batool, S., & Sarwat, A. I. (2021) · SoutheastCon 2021 · doi:10.1109/southeastcon45413.2021.9401940 · Cited by 38
“Some techniques have been proposed in [11–15] to detect false data injection attack.”
MethodEdge Computing Enabled Resilient Wireless Network Virtualization for Internet of Things
Rawat, D. B., Parwez, M. S., & Alshammari, A. (2017) · 2017 IEEE 3rd International Conference on Collaboration and Internet Computing (CIC) · doi:10.1109/cic.2017.00030 · Cited by 23
“For instance, smart energy grid requires latency less than 10 millisecond for time critical information to avoid power outage because of malicious actions [2], [4].”
BackgroundSelf-citation
Metadata
- Authors
- Rawat, D. B., & Bajracharya, C.
- Venue
- IEEE Signal Processing Letters
- Published
- 2015-10
- Volume
- 22
- Issue
- 10
- Pages
- 1652-1656
- ISSN
- 1070-9908 (ISSN-L)
- 1558-2361
- OpenAlex
- W2091497071
- Cited by
- 240
- References
- 1
- FWCI
- 12.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.