The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Predictive Control for Energy Efficient Buildings with Thermal Storage: Modeling, Stimulation, and Experiments
Abstract
The building sector is the largest energy consumer in the world. Therefore, it is economically, socially, and environmentally significant to reduce the energy consumption of buildings. Achieving substantial energy reduction in buildings may require rethinking the whole processes of design, construction, and operation of a building. This article focuses on the specific issue of advanced control system design for energy efficient buildings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Constrained model predictive control: Stability and optimality
Mayne, D. Q., Rawlings, J. B., Rao, C. V., & Scokaert, P. O. M. (2000) · Automatica · doi:10.1016/s0005-1098(99)00214-9 · Cited by 8,736
Lienhard, J. H. (1981) · Cited by 2,748
Blanchini, F. (1999) · Automatica · doi:10.1016/s0005-1098(99)00113-2 · Cited by 2,390
Model Predictive Control for the Operation of Building Cooling Systems
Ma, Y., Borrelli, F., Hencey, B., Coffey, B., Bengea, S., & Haves, P. (2012) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2011.2124461 · Cited by 527
Oldewurtel, F., Parisio, A., Jones, C. N., Morari, M., Gyalistras, D., Gwerder, M., Stauch, V, Lehmann, B., & Wirth, K. (2010) · Proceedings of the 2010 American Control Conference · doi:10.1109/acc.2010.5530680 · Cited by 435
Constrained Optimal Control of Linear and Hybrid Systems
(2003) · Lecture Notes in Control and Information Sciences · doi:10.1007/3-540-36225-8 · Cited by 429
Reducing energy costs and peak electrical demand through optimal control of building thermal storage
Braun, J. E. (1990) · Cited by 350
Evaluation of optimal control for active and passive building thermal storage
Henze, G. P., Felsmann, C., & Knabe, G. (2004) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2003.06.001 · Cited by 328
An Inverse Gray-Box Model for Transient Building Load Prediction
Braun, J. E., & Chaturvedi, N. (2002) · HVAC&R Research · doi:10.1080/10789669.2002.10391290 · Cited by 328
Model Predictive Control of thermal energy storage in building cooling systems
Ma, Y., Borrelli, F., Hencey, B., Packard, A., & Bortoff, S. (2009) · Proceedings of the 48h IEEE Conference on Decision and Control (CDC) held jointly with 2009 28th Chinese Control Conference · doi:10.1109/cdc.2009.5400677 · Cited by 196
Cited by
Shaikh, P. H., Nor, N. B. M., Nallagownden, P., Elamvazuthi, I., & Ibrahim, T. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.03.027 · Cited by 866
Energy management and planning in smart cities
Calvillo, C. F., Sánchez-Miralles, A., & Villar, J. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.10.133 · Cited by 479
Ten Questions Concerning Model Predictive Control for Energy Efficient Buildings
Killian, M., & Kozek, M. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.05.034 · Cited by 463
Building modeling as a crucial part for building predictive control
Prívara, S., Cigler, J., Váňa, Z., Oldewurtel, F., Sagerschnig, C., & Žáčeková, E. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2012.10.024 · Cited by 348
Zhuang, J., Chen, Y., & Chen, X. (2018) · Building and Environment · doi:10.1016/j.buildenv.2017.10.022 · Cited by 44
Metadata
- Venue
- IEEE Control Systems
- Published
- 2012-02
- Volume
- 32
- Issue
- 1
- Pages
- 44-64
- ISSN
- 1066-033X (ISSN-L)
- 1941-000X
- OpenAlex
- W2092792488
- Cited by
- 347
- References
- 19
- FWCI
- 72.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Predictive Control for Energy Efficient Buildings with Thermal Storage: Modeling, Stimulation, and Experiments. https://app.cochat.ai/papers/10.1109/mcs.2011.2172532
- The paper
- Predictive Control for Energy Efficient Buildings with Thermal Storage: Modeling, Stimulation, and Experiments. (2012). IEEE Control Systems. https://doi.org/10.1109/mcs.2011.2172532
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.