Cited by 317Smart Grid Security and ResilienceStability and Control of Uncertain SystemsInformation and Cyber Security

The DOI matches its Crossref record; 63 of the 64 references it cites were found in a registry or an index.

Secure Control Systems: A Quantitative Risk Management Approach

Abstract

Critical infrastructures must continuously operate safely and reliably, despite a variety of potential system disturbances. Given their strict operating requirements, such systems are automated and controlled in real time by several digital controllers receiving measurements from sensors and transmitting control signals to actuators. Since these physical systems are often spatially distributed, there is a need for information technology (IT) infrastructures enabling the timely data flow between the system components. These networked control systems are ubiquitous in modern societies [1]. Examples include the electric power network, intelligent transport systems, and industrial processes.

Overview

Integrity signals

Registry

Crossref · 10.1109/mcs.2014.2364709

Cites

63 of 63 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Flagged first, then by citations

Show all 64 references

1 of the 64 references couldn’t be matched to a known paper.

Research works printed but not linked: 4

  1. 2012, NIST special publication 800-30: Guide for conducting risk assessments, U S Dept Commerce Natl Inst Standards Technol Revision 1 Tech Rep NIST SP 800-30 Rev 1
  2. ding, 2008, Model-based Fault Diagnosis Techniques Design Schemes
  3. falliere, 2011, W32. Stuxnet dossier, Symantec
  4. gorman, 2009, Electricity grid in U.S. penetrated by spies, Wall Street J, 1a

Cited by

Sorted by citations

Items 301–317 of 317

Metadata

Authors
Teixeira, A. M. H., Sou, K. C., Sandberg, H., & Johansson, K. H.
Affiliations
  • KTH Royal Institute of Technology (SE)
  • Chalmers University of Technology (SE)
  • Swedish Research Council (SE)
Venue
IEEE Control Systems
Published
2015-02
Volume
35
Issue
1
Pages
24-45
ISSN
  • 1066-033X (ISSN-L)
  • 1941-000X
OpenAlex
W1987806716
Cited by
316
References
64
Citations by year
2026: 14 · 2025: 25 · 2024: 27 · 2023: 36 · 2022: 23 · 2021: 23 · 2020: 37 · 2019: 37 · 2018: 32 · 2017: 22 · 2016: 30 · 2015: 10
FWCI
29.01
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Control Systems (publishedVersion)
  • CaltechAUTHORS (California Institute of Technology) (submittedVersion)
  • Lund University Publications (Lund University) (submittedVersion)
  • Chalmers Publication Library (Chalmers University of Technology) (submittedVersion)
  • Chalmers Research (Chalmers University of Technology) (submittedVersion)
Funders
European Commission
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Smart Grid Security and Resilience
  • Physical Sciences › Engineering › Control and Systems Engineering › Stability and Control of Uncertain Systems
  • Physical Sciences › Computer Science › Information Systems › Information and Cyber Security
Keywords
quantitative risk management, networked control systems, critical infrastructure, cyber-physical security, real-time control, distributed control, IT infrastructure

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review