Estimating respiratory frequency from autoregressive spectral analysis of heart period.
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
In this article we report the results of a pilot study and a larger investigation that examined the relationship between respiration frequency assessed using the traditional mercury strain gauge and using the central frequency of the HF component derived from autoregressive spectral analysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The central frequency of HF-HRV is highly correlated with strain gage measures of respiration (Thayer et al., 2002).”
From Heart Rate Variability and Cardiac Vagal Tone in Psychophysiological Research – Recommendations for Experiment Planning, Data Analysis, and Data Reporting (2017) · cites this paper as Thayer et al., 2002
In the citing paper
“This is one reason why the autoregressive analysis of HR is preferred to Fast Fourier Transform in this case (Thayer et al., 2002).”
From Heart Rate Variability and Cardiac Vagal Tone in Psychophysiological Research – Recommendations for Experiment Planning, Data Analysis, and Data Reporting (2017) · cites this paper as Thayer et al., 2002
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Akselrod, S., Gordon, D., Ubel, F. A., Shannon, D. C., Berger, A. C., & Cohen, R. J. (1981) · Science · doi:10.1126/science.6166045 · Cited by 5,079 · cited 1×
“Spectral analysis of HP variability is a method that has been widely recommended and employed in deriving indices that reflect sympathetic and parasympathetic cardiovascular influences [2]-[5].”
MethodPagani, M., Lombardi, F., Guzzetti, S., Rimoldi, O., Furlan, R., Pizzinelli, P., Sandrone, G., Malfatto, G., Dell'Orto, S., & Piccaluga, E. (1986) · Circulation Research · doi:10.1161/01.res.59.2.178 · Cited by 4,130
Assessment of autonomic function in humans by heart rate spectral analysis
Pomeranz, B., Macaulay, R. J., Caudill, M. A., Kutz, I., Adam, D., Gordon, D., Kilborn, K. M., Barger, A. C., Shannon, D. C., Cohen, R. J., et al. (1985) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1985.248.1.h151 · Cited by 2,876
Modern Spectral Estimation: Theory and Application
Kay, S. (1988) · Medical Entomology and Zoology · Cited by 2,480
LANGLEY, J. N. (1903) · Brain · doi:10.1093/brain/26.1.1 · Cited by 1,656
Autonomic characteristics of generalized anxiety disorder and worry
Thayer, J. F., Friedman, B. H., & Borkovec, T. D. (1996) · Biological Psychiatry · doi:10.1016/0006-3223(95)00136-0 · Cited by 857
Self-citationGrossman, P., Karemaker, J., & Wieling, W. (1991) · Psychophysiology · doi:10.1111/j.1469-8986.1991.tb00412.x · Cited by 471
Beat-to-beat variations of heart rate reflect modulation of cardiac autonomic outflow
Saul, J. (1990) · Physiology · doi:10.1152/physiologyonline.1990.5.1.32 · Cited by 424
Baselli, G., Cerutti, S., Civardi, S., Lombardi, F., Malliani, A., Merri, M., Pagani, M., & Rizzo, G. (1987) · International Journal of Bio-Medical Computing · doi:10.1016/0020-7101(87)90014-6 · Cited by 217
Research works printed but not linked: 2
- Latson, 1994, Principles and applications of heart rate variability analysis, 307
- Bronis, 1983, Heart rate variability and autonomous system: Some possible relations, Automedica, 4, 223
Cited by
Laborde, S., Mosley, E., & Thayer, J. F. (2017) · Frontiers in Psychology · doi:10.3389/fpsyg.2017.00213 · Cited by 2,336
“This is one reason why the autoregressive analysis of HR is preferred to Fast Fourier Transform in this case (Thayer et al., 2002).”
BackgroundMethodInfluentialSelf-citationNeural correlates of heart rate variability during emotion
Lane, R. D., McRae, K., Reiman, E. M., Chen, K., Ahern, G. L., & Thayer, J. F. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.07.056 · Cited by 682
“We derived a respiratory rate measurement by applying an autoregressive (AR) algorithm to each 1-minute ECG tracing corresponding to each PET scan (Thayer et al., 2002).”
MethodSelf-citationWilliams, D. P., Cash, C., Rankin, C., Bernardi, A., Koenig, J., & Thayer, J. F. (2015) · Frontiers in Psychology · doi:10.3389/fpsyg.2015.00261 · Cited by 389
“Additionally, high-frequency peak values (HF peak) were obtained from the autoregressive analysis as a measure of respiration frequency to control for potential bias (Thayer et al., 2002).”
MethodSelf-citationBreathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review
Charlton, P. H., Birrenkott, D. A., Bonnici, T., Pimentel, M. A. F., Johnson, A. E. W., Alastruey, J., Tarassenko, L., Watkinson, P. J., Beale, R., & Clifton, D. A. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2763681 · Cited by 379
“• Spectral analysis: identify the respiratory frequency from a power spectrum calculated using either: the fast Fourier Transform [8] (which can operate on unevenly sampled signals [87]), auto-regressive spectral analysis using Burg or Yule-Walker algorithms [199], the Welch periodogram [111], the short-time Fourier t…”
Charlton, P. H., Bonnici, T., Tarassenko, L., Clifton, D. A., Beale, R., & Watkinson, P. J. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/4/610 · Cited by 366
“EF2 Auto-regressive spectral analysis (Thayer et al 2002) using model order 8 (Orphanidou et al 2013).”
Method
Metadata
- Authors
- Thayer, J. F., Sollers, J. J., Ruiz-Padial, E., & Vila, J.
- Affiliations
- Universidad de Jaén (ES)
- National Institute on Aging (US)
- Universidad de Granada (ES)
- ORCID
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 2002-07
- Volume
- 21
- Issue
- 4
- Pages
- 41-45
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W2034557419
- Cited by
- 111
- References
- 15
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 3 · 2023: 7 · 2022: 5 · 2021: 6 · 2020: 6 · 2019: 4 · 2018: 6 · 2017: 9 · 2016: 8 · 2015: 8 · 2014: 7 · 2013: 6 · 2012: 3
- FWCI
- 1.09
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Engineering in Medicine and Biology Magazine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- heart period, autoregressive spectral analysis, high-frequency heart rate variability, respiratory monitoring, autonomic nervous system
- MeSH terms
- Algorithms, Electrocardiography, Female, Fourier Analysis, Heart Rate, Humans, Models, Biological, Pilot Projects, Regression Analysis, Respiration, Signal Processing, Computer-Assisted, Statistics as Topic, Students, Universities, Models, Statistical, Sample Size
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimating respiratory frequency from autoregressive spectral analysis of heart period. https://app.cochat.ai/papers/10.1109/memb.2002.1032638
- The paper
- Thayer, J. F., Sollers, J. J., Ruiz-Padial, E., & Vila, J. (2002). Estimating respiratory frequency from autoregressive spectral analysis of heart period. IEEE Engineering in Medicine and Biology Magazine. https://doi.org/10.1109/memb.2002.1032638
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.