The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Dynamically responsive intervention for tremor suppression
Abstract
The DRIFTS (Dynamically Responsive Intervention For Tremor Suppression) project aims to create wearable active orthoses that suppress upper-limb tremor while allowing natural movement. We present an overview this multidisciplinary project. This project is financially supported by the European Commission's Fifth Framework Programme and aims to create proof-of-concept prototypes of wearable active orthoses for the suppression of upper limb tremor while preserving natural movement. Another major goal of the project is the development of a prototyping and evaluation platform for the future elaboration of wearable ambulatory tremor suppression devices. The prototyping platform will be used to assess the efficacy of available sensing, actuating, and control technologies for tremor suppression.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and more than a quarter struggle to find relief through conventional treatments [7].”
From Controlling a motorized orthosis to follow elbow volitional movement: tests with individuals with pathological tremor (2019) · cites this paper as [7]
Citations
Cites
Conducting polymer artificial muscles
Baughman, R. H. (1996) · Synthetic Metals · doi:10.1016/0379-6779(96)80158-5 · Cited by 870 · cited 1×
“The possibility of using the change in mechanical properties (primarily volume and length changes) was recognized as making possible electro-chemo-mechanical actuators, or “artificial muscles [ 15 ].”
BackgroundSynthetic metals: a novel role for organic polymers
MacDiarmid, A. G. (2001) · Synthetic Metals · doi:10.1016/s0379-6779(01)00508-2 · Cited by 754
Rabinow, J. (1948) · Transactions of the American Institute of Electrical Engineers · doi:10.1109/t-aiee.1948.5059821 · Cited by 633 · cited 1×
“MRFs: What They Are and How They Work MRFs were developed in 1948 by Jacob Rabinow at the U.S. National Bureau of Standards [ 22 ].”
BackgroundNobel Lecture: “Synthetic metals”: A novel role for organic polymers
MacDiarmid, A. G. (2001) · Reviews of Modern Physics · doi:10.1103/revmodphys.73.701 · Cited by 340
Fast contracting polypyrrole actuators
Madden, J. D., Cush, R. A., Kanigan, T. S., & Hunter, I. W. (2000) · Synthetic Metals · doi:10.1016/s0379-6779(00)00195-8 · Cited by 262 · cited 1×
“The limits to the speed of the actuation have been explored up to 30 Hz, using the bending beam technique, but the calculated volume change diminished by a factor of about 10 [ 17 ].”
MethodAdaptive cancelling of physiological tremor for improved precision in microsurgery
Riviere, C. N., Rader, R. S., & Thakor, N. V. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686791 · Cited by 260 · cited 1×
“It is used by Riviere et al. [ 6 ] to develop an adaptive filter to cancel physiological tremor during surgery.”
Method(1984) · Palgrave Macmillan UK eBooks · doi:10.1007/978-1-349-06757-2 · Cited by 213
A Conducting Polymer Artificial Muscle with 12 % Linear Strain
Bay, L., West, K., Sommer‐Larsen, P., Skaarup, S., & Benslimane, M. (2003) · Advanced Materials · doi:10.1002/adma.200390075 · Cited by 212
Self-citationCapillary Force Lithography: Large-Area Patterning, Self-Organization, and Anisotropic Dewetting
Suh, K. Y., & Lee, H. H. (2002) · Advanced Functional Materials · doi:10.1002/1616-3028(20020618)12:6/7<437::aid-adfm437>3.0.co;2-i · Cited by 195 · cited 1×
“Our results in the present project indicate that it may be possible to reach higher frequencies, while retaining significant forces, by disregarding the goal of large linear extensions and instead use the difference in strength and stiffness between the oxidized and reduced states [ 18 ]-[21].”
BackgroundAN INVESTIGATION INTO THE VALUE OF TREATING INTENTION TREMOR BY WEIGHTING THE AFFECTED LIMB
HEWER, R. L., COOPER, R., & MORGAN, M. H. (1972) · Brain · doi:10.1093/brain/95.3.579 · Cited by 112 · cited 1×
“The added inertia of wrist weights attenuates cerebellar tremor and is useful in some patients [ 4 ].”
Background
Research works printed but not linked: 9
- Watts, 1997, Movement Disorders
- McDowell, 1987, The extrapyramidal system and disorders of movement, 3
- Riviere, 1995, Adaptive real-time canceling of physiological tremor for microsurgery, 89
- Gonzalez, 1995, A new approach to suppressing abnormal tremor through signal equalization, 707
- Hendriks, 1991, A second-generation joystick for people disable by tremor, 248
- Rosen, 1995, A controlled-energy dissipation orthosis for functional suppression of intention tremors, J. Rehabil. Res. Develop., 32, 1
- Michaelis, 1988, Introducing the neat eater, Action Res., 6, 2
- Carlson, 2000, Controllable fluids in 2000—Status of ER and MR fluid technology, 126
- Lord Corporation
Cited by
Biomedical applications of soft robotics
Cianchetti, M., Laschi, C., Menciassi, A., & Dario, P. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0022-y · Cited by 1,435
A review of smart homes—Present state and future challenges
Chan, M., Estève, D., Escriba, C., & Campo, E. (2008) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2008.02.001 · Cited by 1,007
Advances in wearable technology and applications in physical medicine and rehabilitation
Bonato, P. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-2 · Cited by 385
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349
“In the framework of the DRIFTS (dynamically responsive intervention for tremor suppression) project [7], the WOTAS exoskeleton was presented with three main objectives: monitoring, diagnosis, and validation of nongrounded tremor reduction strategies [8].”
MethodSelf-citationCarbon‐Nanotube‐Reinforced Polyaniline Fibers for High‐Strength Artificial Muscles
Spinks, G. M., Mottaghitalab, V., Bahrami‐Samani, M., Whitten, P. G., & Wallace, G. G. (2006) · Advanced Materials · doi:10.1002/adma.200502366 · Cited by 278
Metadata
- Authors
- Manto, M., Topping, M., Soede, M., Sanchez-Lacuesta, J., Harwin, W., Pons, J., Williams, J., Skaarup, S., & Normie, L.
- Affiliations
- Université Libre de Bruxelles (BE)
- University of Reading (GB)
- Consejo Superior de Investigaciones Científicas (ES)
- De Montfort University (GB)
- Technical University of Denmark (DK)
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 2003-05
- Volume
- 22
- Issue
- 3
- Pages
- 120-132
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W2060710550
- Cited by
- 81
- References
- 19
- Citations by year
- 2025: 1 · 2024: 2 · 2023: 1 · 2022: 2 · 2021: 3 · 2020: 5 · 2019: 4 · 2018: 3 · 2017: 3 · 2016: 3 · 2015: 1 · 2014: 4 · 2013: 2 · 2012: 3
- FWCI
- 4.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Engineering in Medicine and Biology Magazine (publishedVersion)
- PubMed (publishedVersion)
- Dépôt institutionnel de l'Université libre de Bruxelles (Université Libre de Bruxelles) (submittedVersion)
- DMU Open Research Archive (De Montfort University) (submittedVersion)
- Funders
- De Montfort University
- University of Leicester
- University of Southampton
- Cranfield University
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- tremor suppression, upper limb tremor, control technology, prototyping platform
- MeSH terms
- Clothing, Diagnosis, Computer-Assisted, Equipment Design, Feedback, Humans, Miniaturization, Movement, Orthotic Devices, Parkinson Disease, Prosthesis Design, Textiles, Therapy, Computer-Assisted, Tremor, Monitoring, Ambulatory, Essential Tremor, Upper Extremity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamically responsive intervention for tremor suppression. https://app.cochat.ai/papers/10.1109/memb.2003.1213635
- The paper
- Manto, M., Topping, M., Soede, M., Sanchez-Lacuesta, J., Harwin, W., Pons, J., Williams, J., Skaarup, S., & Normie, L. (2003). Dynamically responsive intervention for tremor suppression. IEEE Engineering in Medicine and Biology Magazine. https://doi.org/10.1109/memb.2003.1213635
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.