CoChat

Harmonic Mitigation of Variable Speed Drive with Shunt Active Filter Connected via LCL Coupler

El Korfolly, M. I., Htita, Ibrahim, Elmasry, Said, Abdalla, Omar H. · 2023 · 2023 24th International Middle East Power System Conference (MEPCON)

The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.

Abstract

Nowadays, the applications of nonlinear loads are extended to various types including variable speed drives, arc furnaces, computers and other electronic loads. These nonlinear loads generate harmonics, which cause excessive heating of conductors and pulsating torque of motors. This paper presents a shunt active filter used to mitigate the harmonic distortion produced by Variable Speed Drive (VSD) systems. A VSD load is connected at a certain bus in a simulated 14-bus Cigre benchmark distribution network. A shunt active filter is used to mitigate the VSD harmonics. The shunt active filter is controlled by a hysteresis controller and is coupled to the network through an LCL link. Harmonic analyses are performed using the fast Fourier transform and according to the IEEE Standard 519-2014. Three cases are considered: (i) no active filter; (ii) installing an active filter coupled to the network through an L link; and (iii) installing an active filter coupled through an LCL link. Simulation studies are performed by using the MATLAB/Simulink software. The results have shown that the shunt active filter with the LCL coupler reduces the harmonic distortion compared to the coupling through the L only.

Overview

Integrity signals

Registry

Crossref · 10.1109/mepcon58725.2023.10462331

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 44 references

Research works printed but not linked: 4

  1. Abdalla, 2019, Technical Requirements for Connecting Solar Power Plants to Electricity Networks” Book Chapter in “Innovation in Energy Systems - New Technologies for Changing Paradigms, IntechOpen, 1
  2. Abdalla, 2023, Technical Requirements of Connecting Wind Farms to the Egyptian Grid Based on the Wind Farm Grid Connection Code, Journal of the Egyptian Society of Engineers, 62, 16
  3. 2018, Microgrid Stability Definitions, Analysis, and Modeling
  4. Lettl, Comparison of different filter types for grid connected inverter, 1426

Cited by

See all 5

Metadata

Authors
El Korfolly, M. I., Htita, I., Elmasry, S., & Abdalla, O. H.
Affiliations
  • Helwan University,Faculty of Engineering at Helwan,Dept. of Electrical Power and Machines Engineering,Cairo,Egypt
  • Helwan University (EG)
Venue
2023 24th International Middle East Power System Conference (MEPCON)
Publisher
IEEE
Published
2023-12-19
Pages
1-7
OpenAlex
W4392904912
Cited by
5
References
44
Citations by year
2026: 1 · 2025: 1 · 2024: 3
FWCI
2.45
Type
conference paper
Language
en
Open access
closed
Locations
International Middle East Power Systems Conference (MEPCON) (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electromagnetic Compatibility and Noise Suppression
Keywords
harmonic compensation, shunt active power filter, variable frequency drive, nonlinear loads, hysteresis current control, harmonic distortion, IEEE 519-2014, power quality

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Harmonic Mitigation of Variable Speed Drive with Shunt Active Filter Connected via LCL Coupler. https://app.cochat.ai/papers/10.1109/mepcon58725.2023.10462331
The paper
El Korfolly, M. I., Htita, I., Elmasry, S., & Abdalla, O. H. (2023). Harmonic Mitigation of Variable Speed Drive with Shunt Active Filter Connected via LCL Coupler. 2023 24th International Middle East Power System Conference (MEPCON). https://doi.org/10.1109/mepcon58725.2023.10462331

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.