Harmonic Mitigation of Variable Speed Drive with Shunt Active Filter Connected via LCL Coupler
The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Nowadays, the applications of nonlinear loads are extended to various types including variable speed drives, arc furnaces, computers and other electronic loads. These nonlinear loads generate harmonics, which cause excessive heating of conductors and pulsating torque of motors. This paper presents a shunt active filter used to mitigate the harmonic distortion produced by Variable Speed Drive (VSD) systems. A VSD load is connected at a certain bus in a simulated 14-bus Cigre benchmark distribution network. A shunt active filter is used to mitigate the VSD harmonics. The shunt active filter is controlled by a hysteresis controller and is coupled to the network through an LCL link. Harmonic analyses are performed using the fast Fourier transform and according to the IEEE Standard 519-2014. Three cases are considered: (i) no active filter; (ii) installing an active filter coupled to the network through an L link; and (iii) installing an active filter coupled through an LCL link. Simulation studies are performed by using the MATLAB/Simulink software. The results have shown that the shunt active filter with the LCL coupler reduces the harmonic distortion compared to the coupling through the L only.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Design and Control of an LCL-Filter-Based Three-Phase Active Rectifier
Liserre, M., Blaabjerg, F., & Hansen, S. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.853373 · Cited by 2,402
(2008) · Wiley eBooks · doi:10.1002/9780470754245 · Cited by 566
Design and Performance Analysis of Three-Phase Solar PV Integrated UPQC
Devassy, S., & Singh, B. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2754983 · Cited by 220
Progress in Electromagnetics Research Symposium
(1997) · Annales Des Télécommunications · doi:10.1007/bf02998452 · Cited by 175
Comparison of L, LC & LCL filter for grid connected converter
Yagnik, U. P., & Solanki, M. D. (2017) · International Conference on Trends in Electronics and Informatics (ICOEI) · doi:10.1109/icoei.2017.8300968 · Cited by 57
Implementation of Solar Photovoltaic System With Universal Active Filtering Capability
Devassy, S., & Singh, B. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2906297 · Cited by 54
Jayasankar, V. N., & Vinatha, U. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.3025520 · Cited by 49
Hysteresis Control for Shunt Active Power Filter under Unbalanced Three-Phase Load Conditions
Chelli, Z., Toufouti, R., Omeiri, A., & Saad, S. (2015) · Journal of Electrical and Computer Engineering · doi:10.1155/2015/391040 · Cited by 41
Power Quality Enhancement in PV and Battery Storage Based Microgrid Using Hybrid Active Filter
Das, S. R., Ray, P. K., Mohanty, A., & Panda, G. (2021) · International Conference on Energy, Power and Environment (ICEPE) · doi:10.1109/icepe50861.2021.9404453 · Cited by 23
Research works printed but not linked: 4
- Abdalla, 2019, Technical Requirements for Connecting Solar Power Plants to Electricity Networks” Book Chapter in “Innovation in Energy Systems - New Technologies for Changing Paradigms, IntechOpen, 1
- Abdalla, 2023, Technical Requirements of Connecting Wind Farms to the Egyptian Grid Based on the Wind Farm Grid Connection Code, Journal of the Egyptian Society of Engineers, 62, 16
- 2018, Microgrid Stability Definitions, Analysis, and Modeling
- Lettl, Comparison of different filter types for grid connected inverter, 1426
Cited by
Shunt Active Power Filters in Three-Phase, Three-Wire Systems: A Topical Review
Popescu, M., Bitoleanu, A., Suru, C. V., et al. (2024) · Energies · doi:10.3390/en17122867 · Cited by 46
“The algorithms for the reference current generation in the frequency domain are mainly based on Fourier analysis of the distorted load currents, which involves either fast Fourier transform (FFT) [20,21,106,212–214] or, more frequently, discrete Fourier transform (DFT) [20,100,145,211,215–217].”
BackgroundMethodTopology design of variable speed drive systems for enhancing power quality in industrial grids
Nadweh, S., Mohammed, N., Alshammari, O., et al. (2024) · Electric Power Systems Research · doi:10.1016/j.epsr.2024.111114 · Cited by 9
Özer, A. S., Sevilmiş, F., Karaca, H., et al. (2026) · Protection and Control of Modern Power Systems · doi:10.23919/pcmp.2025.000070 · Cited by 5
Li, S., Mao, Y., & Zheng, Z. (2025) · Journal of Power Electronics · doi:10.1007/s43236-024-00985-0 · Cited by 1
“According to IEEE standard 519-2014, a total demand distortion (TDD) analysis is conducted on the grid-connected current [18, 19].”
Study of the Flicker Phenomenon Induced in the Electric Arc Furnace of the Steel Factory in Tunisia
Tlili, F., Slimene, M. B., Khlifi, M. A., et al. (2024) · IEEE Access · doi:10.1109/access.2024.3502428 · Cited by 1
Metadata
- Authors
- El Korfolly, M. I., Htita, I., Elmasry, S., & Abdalla, O. H.
- Affiliations
- Helwan University,Faculty of Engineering at Helwan,Dept. of Electrical Power and Machines Engineering,Cairo,Egypt
- Helwan University (EG)
- ORCID
- Abdalla, Omar H.
- Venue
- 2023 24th International Middle East Power System Conference (MEPCON)
- Publisher
- IEEE
- Published
- 2023-12-19
- Pages
- 1-7
- OpenAlex
- W4392904912
- Semantic Scholar
- 6c1c2fa682c8f1c241c770bedbd57cefc5457858
- Cited by
- 5
- References
- 44
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 3
- FWCI
- 2.45
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- International Middle East Power Systems Conference (MEPCON) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electromagnetic Compatibility and Noise Suppression
- Keywords
- harmonic compensation, shunt active power filter, variable frequency drive, nonlinear loads, hysteresis current control, harmonic distortion, IEEE 519-2014, power quality
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Harmonic Mitigation of Variable Speed Drive with Shunt Active Filter Connected via LCL Coupler. https://app.cochat.ai/papers/10.1109/mepcon58725.2023.10462331
- The paper
- El Korfolly, M. I., Htita, I., Elmasry, S., & Abdalla, O. H. (2023). Harmonic Mitigation of Variable Speed Drive with Shunt Active Filter Connected via LCL Coupler. 2023 24th International Middle East Power System Conference (MEPCON). https://doi.org/10.1109/mepcon58725.2023.10462331
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.