Cited by 8Scientific Measurement and Uncertainty EvaluationInertial Sensor and NavigationSensor Technology and Measurement Systems

Managing the sampling rate variability of digital MEMS accelerometers in dynamic calibration

Open access
D'Emilia, Giulio, Gaspari, Antonella, Natale, Emanuela, Prato, Andrea, Mazzoleni, Fabrizio, Schiavi, Alessandro·2021·2021 IEEE International Workshop on Metrology for Industry 4.0 & IoT (MetroInd4.0&IoT)

Abstract

The use of sensors with digital interface, within large or dense sensor networks, is nowadays widespread in many scientific and technological applications: from more traditional applications, such as infrastructure monitoring and predictive maintenance, up to the advanced ones, such as smart manufacturing, IoT, Machine Learning, and other emerging fields of fast-real-time interconnections, within the framework of digitalization. The technical and functional performance of these sensing infrastructures, if accurately identified, allows to enhance the trustworthiness, safety, and accuracy of the managed processes; based on metrological characterizations and calibration, it is possible to provide the actual sensitivity of digital sensors with respect to reference physical stimuli, within the proper uncertainty budgets and suitable covering factors. At present days, metrological characterization and proper calibration of digital sensors is still a technical and methodological challenge and several studies are oriented along with this perspective. In this paper, the sampling rate variability - depending on MEMS analog-to-digital converter, external microcontroller internal clock and their interaction - of digital MEMS accelerometers in dynamic calibration is investigated. The sampling rate variability is evaluated among 25 sensors of the same batch, and within every single sensor in time, and methods to manage the associated uncertainty and to avoid mismatches in calibration, are proposed and discussed.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/metroind4.0iot51437.2021.9488520

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
D'Emilia, G., Gaspari, A., Natale, E., Prato, A., Mazzoleni, F., & Schiavi, A.
Affiliations
  • Polytechnic University of Bari (IT)
  • University of L'Aquila (IT)
  • Istituto Nazionale di Ricerca Metrologica (IT)
Venue
2021 IEEE International Workshop on Metrology for Industry 4.0 & IoT (MetroInd4.0&IoT)
Publisher
IEEE
Published
2021-06-07
Pages
687-692
OpenAlex
W3184387690
Cited by
8
References
16
Citations by year
2026: 2 · 2025: 2 · 2023: 4
FWCI
3.19
Type
conference paper
Language
en
Open access
Locations
  • IEEE International Workshop on Metrology for Industry 4.0 & IoT (MetroInd4.0&IoT) (publishedVersion)
  • CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica) (submittedVersion, other-oa)
  • Archivio Istituzionale della Ricerca - Università degli Studi dell Aquila (submittedVersion, cc-by-nc-nd)
Topics
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Scientific Measurement and Uncertainty Evaluation
  • Physical Sciences › Engineering › Aerospace Engineering › Inertial Sensor and Navigation
  • Physical Sciences › Computer Science › Computer Networks and Communications › Sensor Technology and Measurement Systems
Keywords
dynamic calibration, analog-to-digital converter, measurement uncertainty, sensor networks

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›