Managing Industrial Energy Intelligently: Demand Response Scheme
The DOI matches its Crossref record; 19 of the 21 references it cites were found in a registry or an index.
Abstract
Electric demand-side management (DSM) focuses on changing the electricity consumption patterns of end-use customers through improving energy efficiency and optimizing the allocation of power. Demand response (DR ) is a DSM solution that targets residential, commercial, and industrial customers and is developed for demand reduction or demand shifting at a specific time for a specific duration. In the absence of on-site generation or the possibility of demand shifting, the consumption level needs to be lowered. While the noncriticality of loads at the residential and commercial levels allows for demand reduction with relative ease, demand reduction of industrial processes requires a more sophisticated solution. Production constraints, inventory constraints, maintenance schedules, and crew management are some of the many factors that have to be considered before one or more processes can be temporarily shut down. An intelligent system is designed in this article for implementation of DR at an industrial site. Based on the various operational constraints of the industrial process, it determines the loads that could be potentially curtailed. Fuzzy/expert systems are used to derive a priority factor for different candidate loads. This information can then be used by the plant operator/DR client to make a comply/opt out decision during a utility-initiated DR event.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It has been reported that for many utilities 2 -10% of the industrial consumers are responsible for at least 80% of the electricity usage [58].”
From An overview of Demand Response: Key-elements and international experience (2017) · cites this paper as [58]
Citations
Cites
Fuzzy logic in control systems: fuzzy logic controller. I
Lee, C. C. (1990) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/21.52551 · Cited by 5,616
Kosko, B. (1986) · International Journal of Man-Machine Studies · doi:10.1016/s0020-7373(86)80040-2 · Cited by 3,576 · cited 1×
“…map (fcm). the fcm was first introduced by the political scientist robert axelrod in the 1970s for representing social scientific knowledge [25]. essentially, it is a directional graph with weighted links (figure 2), where each node (vertex) denotes a data point, application, system…”
BackgroundGHOSH, S., & GAGNON, R. J. (1989) · International Journal of Production Research · doi:10.1080/00207548908942574 · Cited by 538
Brooks, A., Lu, E., Reicher, D., Spirakis, C., & Weihl, B. (2010) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2010.936349 · Cited by 424
Demand Response Architecture: Integration into the Distribution Management System
Mohagheghi, S., Stoupis, J., Wang, Z., Li, Z., & Kazemzadeh, H. (2010) · 2010 First IEEE International Conference on Smart Grid Communications · doi:10.1109/smartgrid.2010.5622094 · Cited by 122
Self-citationIndustrial power demand response analysis for one-part real-time pricing
Roos, J. G., & Lane, I. E. (1998) · IEEE Transactions on Power Systems · doi:10.1109/59.651628 · Cited by 116
An intelligent load shedding (ILS) system application in a large industrial facility
Shokooh, F., Dai, J. J., Shokooh, S., Taster, J., Castro, H., Khandelwal, T., & Donner, G. (2005) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2005.1518342 · Cited by 98
Han, J., & Piette, M. A. (2007) · University of North Texas Digital Library (University of North Texas) · Cited by 90
Song, Y., & Johns, A. T. (1998) · Power Engineering Journal · doi:10.1049/pe:19980403 · Cited by 76
A comparative study on multicriteria ABC analysis in inventory management
Chen, Y., Li, K., & Liu, S. (2008) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/icsmc.2008.4811802 · Cited by 63
Koch, E., & Piette, M. A. (2007) · University of North Texas Digital Library (University of North Texas) · Cited by 36
Artificial Neural Network Based Adaptive Load Shedding for an Industrial Cogeneration Facility
Hsu, C., Chuang, H.-J., & Chen, C. (2008) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/08ias.2008.137 · Cited by 31
An overview of ancillary services in an open market environment
Kuzle, I., Bošnjak, D., & Tešnjak, S. (2007) · Mediterranean Conference on Control and Automation (MED) · doi:10.1109/med.2007.4433835 · Cited by 30
Measuring manufacturing throughput using takt time analysis and simulation
Duanmu, J., & Taaffe, K. (2007) · Winter Simulation Conference · doi:10.1109/wsc.2007.4419783 · Cited by 30
Ancillary services provided from DER with power electronics interface
Yu, X., & Tolbert, L. M. (2006) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2006.1709460 · Cited by 26
Tang, Y., Xu, F., & Chen, L. (2010) · China International Conference on Electricity Distribution (CICED) · Cited by 26
It based energy management through demand side in the industrial sector
Inamdar, H. V., & Hasabe, R. P. (2009) · International Conference on Control and Automation · Cited by 25
Advanced Control Technologies and Strategies Linking Demand Response and Energy Efficiency
Kiliccote, S., & Piette, M. A. (2005) · OakTrust (Texas A&M University Libraries) · Cited by 25
Coe, S., Ott, A. L., & Pratt, D. K. (2010) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2010.936350 · Cited by 17
Research works printed but not linked: 6
- el-metwally, 0, Priority ranking of industrial loads and application of demand side management technique, Proc Int Middle East Power Syst Conf, 341
- delfino, 0, Operation and management of the electric system for industrail plants: An expert system prototype for load-shedding operator assistance, Proc IEEE IAS Gen Meet, 3260
- kiliccote, 0, Advaned controls and communications for demand response and energy efficiency in commercial buildings, Carnegie Mellon Conf Elec Power Sys, 1
- 2002, Demand response: design principles for creating customer and market value, Vallejo CA Tech Rep
- 2007, A primer on demand response, Thomas Wiesel Partners
- 2006, Assessment of Demand Response and Advanced Metering, Staff Report
Cited by
An overview of Demand Response: Key-elements and international experience
Paterakis, N. G., Erdinç, O., & Catalão, J. P. S. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.11.167 · Cited by 779
A Demand Response Energy Management Scheme for Industrial Facilities in Smart Grid
Ding, Y. M., Hong, S. H., & Li, X. H. (2014) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2014.2330995 · Cited by 248
Design and management of a distributed hybrid energy system through smart contract and blockchain
Li, Y., Yang, W., He, P., Chen, C., & Wang, X. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.04.132 · Cited by 233
Residential Demand Side Management model, optimization and future perspective: A review
Panda, S., Mohanty, S., Rout, P. K., Sahu, B. K., Bajaj, M., Zawbaa, H. M., & Kamel, S. (2022) · Energy Reports · doi:10.1016/j.egyr.2022.02.300 · Cited by 221
Mortaji, H., Ow, S. H., Moghavvemi, M., & Almurib, H. A. F. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2740832 · Cited by 201
“Aspresented in [29], DR, as a solution of DR management, targets all industrial, commercial, and residential customers.”
Background
Metadata
- Authors
- Mohagheghi, S., & Raji, N.
- Affiliations
- Colorado School of Mines (US)
- ORCID
- Mohagheghi, Salman
- Venue
- IEEE Industry Applications Magazine
- Published
- 2014-03
- Volume
- 20
- Issue
- 2
- Pages
- 53-62
- ISSN
- 1077-2618 (ISSN-L)
- OpenAlex
- W2039238935
- Cited by
- 52
- References
- 21
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 2 · 2023: 2 · 2022: 7 · 2021: 3 · 2020: 4 · 2019: 8 · 2018: 10 · 2017: 3 · 2016: 7 · 2015: 2 · 2014: 1
- FWCI
- 2.30
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Industry Applications Magazine (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Smart Grid Energy Management
- Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Energy Efficiency and Management
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Power System Optimization
- Keywords
- demand response, demand-side management, industrial energy management, load curtailment, fuzzy expert system, load prioritization, demand reduction, demand shifting, production constraints, intelligent control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.