The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Multi-modality image registration by maximization of mutual information
Abstract
Mutual information of image intensities has been proposed as a new matching criterion for automated multi-modality image registration. In this paper the authors give experimental evidence of the power and the generality of the mutual information criterion by showing results for various applications involving CT, MR and PET images. The authors' results illustrate the large applicability of the approach and demonstrate its high suitability for routine use in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elements of Information Theory
Cover, T. M., & Thomas, J. A. (2001) · Wiley eBooks · doi:10.1002/0471200611 · Cited by 36,808
Numerical recipes in C: the art of scientific computing
(1993) · Choice Reviews Online · doi:10.5860/choice.30-5638 · Cited by 17,933
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · Cited by 15,411
(1973) · CERN Document Server (European Organization for Nuclear Research) · Cited by 12,895
Savitzky-Golay Smoothing Filters
Press, W. H., & Teukolsky, S. A. (1990) · Computers in Physics · doi:10.1063/1.4822961 · Cited by 11,670
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Self-citationPattern Classification and Scene Analysis
Thompson, M., Duda, R. O., & Hart, P. E. (1974) · Leonardo · doi:10.2307/1573081 · Cited by 4,495
A survey of image registration techniques
Brown, L. G. (1992) · ACM Computing Surveys · doi:10.1145/146370.146374 · Cited by 4,057
Alignment by Maximization of Mutual Information
Viola, P., & Wells III, W. M. (1997) · International Journal of Computer Vision · doi:10.1023/a:1007958904918 · Cited by 2,610
Multi-modal volume registration by maximization of mutual information
Wells, W. M., Viola, P., Atsumi, H., Nakajima, S., & Kikinis, R. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80004-9 · Cited by 1,959
MRI-PET Registration with Automated Algorithm
Woods, R. P., Mazziotta, J. C., & R. Cherry, A. S. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199307000-00004 · Cited by 1,617
Alignment by maximization of mutual information
Viola, P., & Wells, W. M. (2002) · Proceedings of IEEE International Conference on Computer Vision · doi:10.1109/iccv.1995.466930 · Cited by 1,082
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Self-citationMedical image matching-a review with classification
van den Elsen, P. A., Pol, E.-J. D., & Viergever, M. A. (1993) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.195938 · Cited by 718
Theory of statistical inference and information
Vajda, I. (1989) · Medical Entomology and Zoology · Cited by 463
Comparison and evaluation of retrospective intermodality image registration techniques:
West, J. B., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, Jr., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A. M. F., et al. (1996) · SPIE Proceedings · doi:10.1117/12.237936 · Cited by 269
Self-citationStatistical Pattern Recognition.
Chen, C. H. (1973) · Cited by 192
Voxel similarity measures for automated image registration
Hill, D., Studholme, C., & Hawkes, D. J. (1994) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.185180 · Cited by 149
Automatic registration of CT and MR brain images using correlation of geometrical features
van den Elsen, P. A., Maintz, J. B. A., Pol, E.-J. D., & Viergever, M. A. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.387719 · Cited by 142
3D Multi-Modality Medical Image Registration Using Feature Space Clustering
Collignon, A. M. F., Vandermeulen, D., Suetens, P., & Marchal, G. (1995) · Lecture notes in computer science · doi:10.1007/978-3-540-49197-2_22 · Cited by 113
Self-citationA new class of similarity measures for robust image registration
Alain Venot, A., Lebruchec, J.-F., & Roucayrol, J. C. (1984) · Computer Vision Graphics and Image Processing · doi:10.1016/s0734-189x(84)80020-1 · Cited by 112
Kalender, W. A. (1992) · Medical Physics · doi:10.1118/1.596899 · Cited by 106
On the problem of geometric distortion in magnetic resonance images for stereotactic neurosurgery
Michiels, J. J., Bosmans, H., Pelgrims, P., Vandermeulen, D., Gybels, J., Marchal, G., & Suetens, P. (1994) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)92200-4 · Cited by 85
Self-citationHill, D., Hawkes, D. J., Harrison, N. A., & Ruff, C. (2005) · Springer eBooks · doi:10.1007/bfb0013788 · Cited by 73
Grey value correlation techniques used for automatic matching of CT and MR brain and spine images
van den Elsen, P. A., Pol, E.-J. D., Sumanaweera, T. S., Hemler, P. F., Napel, S. A., & Adler, J. R. (1994) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.185182 · Cited by 73
Automated 3D Registration of Truncated MR and CT Images of the Head.
Studholme, C., Hill, D., & Hawkes, D. J. (1995) · British Machine Vision Conference (BMVC) · doi:10.5244/c.9.3 · Cited by 45
Pseudocorrelation: A fast, robust, absolute, grey‐level image alignment algorithm
Radcliffe, T. J., Rajapakshe, R., & Shalev, S. (1994) · Medical Physics · doi:10.1118/1.597336 · Cited by 39
Comparison of Feature-Based Matching of CT and MR Brain Images
Maintz, J. B. A., van den Elsen, P. A., & Viergever, M. A. (1995) · Lecture notes in computer science · doi:10.1007/978-3-540-49197-2_25 · Cited by 36
Image fusion using geometrical features
van den Elsen, P. A., Maintz, J. B. A., Pol, E.-J. D., & Viergever, M. A. (1992) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.131076 · Cited by 32
Registration of multimodality medical images using a region overlap criterion
Chiron, P. G., & Bizais, Y. (1992) · CVGIP Graphical Models and Image Processing · doi:10.1016/1049-9652(92)90024-r · Cited by 27
Coincident bit counting-a new criterion for image registration
Chiang, J. Y., & Sullivan, B. J. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.222663 · Cited by 23
Automatic image partitioning for generic object segmentation in medical images
Maes, F., Vandermeulen, D., Suetens, P., & Marchal, G. (1995) · Computational imaging and vision · Cited by 11
Self-citation
Cited by
AVANTS, B., EPSTEIN, C., GROSSMAN, M., & GEE, J. (2008) · Medical Image Analysis · doi:10.1016/j.media.2007.06.004 · Cited by 5,669
A reproducible evaluation of ANTs similarity metric performance in brain image registration
Avants, B. B., Tustison, N. J., Song, G., Cook, P. A., Klein, A., & Gee, J. C. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.09.025 · Cited by 4,796
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
“[10] have verified these results [29], [14].”
MethodSelf-citationMedical image analysis: progress over two decades and the challenges ahead
Duncan, J. S., & Ayache, N. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824822 · Cited by 4,140
A survey of medical image registration
Maintz, J. B. A., & Viergever, M. A. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80026-8 · Cited by 3,327
Metadata
- Authors
- Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P.
- Venue
- Proceedings of the Workshop on Mathematical Methods in Biomedical Image Analysis
- Publisher
- IEEE
- Published
- 1996
- Pages
- 14-22
- OpenAlex
- W2129941787
- Cited by
- 795
- References
- 32
- FWCI
- 8.15
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.