The DOI matches its Crossref record.
Comparison and evaluation of retrospective intermodality image registration techniques:
Abstract
All retrospective image registration methods have attached to them some intrinsic estimate of registration error. However, this estimate of accuracy may not always be a good indicator of the distance between actual and estimated positions of targets within the cranial cavity. This paper describes a project whose principal goal is to use a prospective method based on fiducial markers as a 'gold standard' to perform an objective, blinded evaluation of the accuracy of several retrospective image-to-image registration techniques. Image volumes of three modalities -- CT, MR, and PET -- were taken of patients undergoing neurosurgery at Vanderbilt University Medical Center. These volumes had all traces of the fiducial markers removed, and were provided to project collaborators outside Vanderbilt, who then performed retrospective registrations on the volumes, calculating transformations from CT to MR and/or from PET to MR, and communicated their transformations to Vanderbilt where the accuracy of each registration was evaluated. In this evaluation the accuracy is measured at multiple 'regions of interest,' i.e. areas in the brain which would commonly be areas of neurological interest. A region is defined in the MR image and its centroid C is determined. Then the prospective registration is used to obtain the corresponding point C' in CT or PET. To this point the retrospective registration is then applied, producing C' in MR. Statistics are gathered on the target registration error (TRE), which is the disparity between the original point C and its corresponding point C'. A second goal of the project is to evaluate the importance of correcting geometrical distortion in MR images, by comparing the retrospective TRE in the rectified images, i.e., those which have had the distortion correction applied, with that of the same images before rectification. This paper presents preliminary results of this study along with a brief description of each registration technique and an estimate of both preparation and execution time needed to perform the registration .
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Self-citationMultimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Self-citationA survey of medical image registration
Maintz, J. B. A., & Viergever, M. A. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80026-8 · Cited by 3,327
Mutual-information-based registration of medical images: a survey
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815867 · Cited by 2,890
Automated Image Registration: I. General Methods and Intrasubject, Intramodality Validation
Woods, R. P., Grafton, S. T., Holmes, C. J., Cherry, S. R., & Mazziotta, J. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199801000-00027 · Cited by 1,707
Self-citation
Metadata
- Authors
- West, J. B., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, Jr., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A. M. F., Maes, F., Suetens, P., Vandermeulen, D., van den Elsen, P. A., Hemler, P. F., Napel, S., Sumanaweera, T. S., Harkness, B. A., Hill, D. L., Studholme, C., Malandain, G., Pennec, X., Noz, M. E., Maguire, Jr., Pollack, M., Pelizzari, C. A., Robb, R. A., Hanson, D. P., & Woods, R. P.
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 1996-04-16
- Volume
- 2710
- Pages
- 332-347
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W2090532648
- Cited by
- 269
- References
- 0
- FWCI
- 18.57
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison and evaluation of retrospective intermodality image registration techniques:. https://app.cochat.ai/papers/10.1117/12.237936
- The paper
- West, J. B., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, Jr., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A. M. F., Maes, F., Suetens, P., Vandermeulen, D., van den Elsen, P. A., Hemler, P. F., Napel, S., Sumanaweera, T. S., Harkness, B. A., Hill, D. L., . . . Woods, R. P. (1996). Comparison and evaluation of retrospective intermodality image registration techniques:. SPIE Proceedings. https://doi.org/10.1117/12.237936
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.