Registration of planar film radiographs with computed tomography
The DOI matches its Crossref record.
Abstract
The authors describe a method to register computed tomography (CT) data with planar film radiographs. Previous methods applied to the problem of CT-radiograph registration rely on determining the correspondence between occluding contours of the 3D surface in the CT data with 2D contours in the projection image. These methods implicitly assume that the correspondence is accurate, ignoring fundamental nonlinear differences in the underlying measurements. In contrast, the authors' emphasis has been to directly exploit the relationship between imaging devices. This is performed by registering radiograph data with intensity-corrected simulated radiograph data derived from CT measurements. The authors show that by exploiting the physical relationship between CT and radiograph measurements one can significantly improve registration accuracy. Concomitantly, the authors detail the relationship between CT and radiograph measurements and the primary factors influencing discrepancies between simulated and real radiograph data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A survey of medical image registration
Maintz, J. B. A., & Viergever, M. A. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80026-8 · Cited by 3,327
A comparison of similarity measures for use in 2-D-3-D medical image registration
Penney, G. P., Weese, J., Little, J. A., Desmedt, P., Hill, D. L. G., & hawkes, D. J. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730403 · Cited by 782
A Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
“…(2006), Fu and Kuduvalli (2008b,a), Birkfellner et al. (2003, 2009), Penney et al. (1998), Lemieux et al. (1994), Gong et al. (2006), Gottesfeld Brown and Boult (1996), Hipwell et al. (2003), Ho et al. (2007), Imamura et al. (2002), Jans et al. (2006), Jaramaz and Eckman (2006), Jonic et al.…”
BackgroundInfluential3-D/2-D registration of CT and MR to X-ray images
Tomazevic, D., Likar, B., Slivnik, T., & Pernus, F. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.819277 · Cited by 167
“In [32], the target points were placed randomly in a 1 cube, while we have placed the targets around pedicles, which is the structure image-guided surgery will be performed on.”
BackgroundMethodInfluentialVoxel-based 2-D/3-D registration of fluoroscopy images and CT scans for image-guided surgery
Weese, J., Penney, G. P., Desmedt, P., Buzug, T. M., Hill, D. L. G., & Hawkes, D. J. (1997) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.681173 · Cited by 164
“reconstructed radiographs (DRR’s) from the CT image that are correlated to the X-ray projection [8], [9].”
BackgroundRussakoff, D. B., Rohlfing, T., Mori, K., Rueckert, D., Ho, A., Adler, J. R., & Maurer, C. R. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.856749 · Cited by 142
Accurate and precise 2D–3D registration based on X-ray intensity
Aouadi, S., & Sarry, L. (2008) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2007.05.006 · Cited by 30
“Gradient Correlation (GC) between original and CT-simulated radiographs was used in [7].”
BackgroundMethodInfluential
Metadata
- Authors
- Gottesfeld Brown, L. M., & Boult, T. E.
- Venue
- Proceedings of the Workshop on Mathematical Methods in Biomedical Image Analysis
- Publisher
- IEEE
- Published
- 1996
- Pages
- 42-51
- OpenAlex
- W2029098878
- Cited by
- 57
- References
- 0
- FWCI
- 3.17
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.