Shape bottlenecks and conservative flow systems [medical image analysis]
Abstract
Proposes an alternative to mathematical morphology to analyze complex shapes. This approach aims mainly at the detection of shape bottlenecks which are often of interest in medical imaging because of their anatomical meaning. The detection idea consists in simulating the steady state of an information transmission process between two parts of a complex object in order to highlight bottlenecks as areas of high information flow. This information transmission process is supposed to have a conservative flow which leads to the well-known Dirichlet-Neumann problem. This problem is solved using finite differences, over-relaxation and a raw to fine implementation. The method is applied to the detection of main bottlenecks of brain white matter network, namely corpus callosum, anterior commissure and brain stem.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The principle of inferring connectivity from local orientation fields can lead to problems as soon as pathways overlap, cross, branch, and have complex geometries.
“Conceptually, the principle of inferring connectivity from local orientation fields can lead to problems as soon as pathways overlap, cross, branch, and have complex geometries7, 35, 36.”
From Tractography-based connectomes are dominated by false-positive connections (2016) · cites this paper as [35]
Regions of white matter bottlenecks have been discussed in the past and highlighted as critical with respect to tractographic findings.
“Regions of white matter bottlenecks have been discussed in the past35 and have been highlighted as critical with respect to tractographic findings36.”
From Tractography-based connectomes are dominated by false-positive connections (2016) · cites this paper as [35]
Cites
Scale-space and edge detection using anisotropic diffusion
Perona, P., & Malik, J. (1990) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.56205 · Cited by 12,143 · see citing works
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970 · see citing works
Talairach, J., Tournoux, P., & Rayport, M. (1988) · Thieme eBooks · Cited by 5,058 · see citing works
Image Selective Smoothing and Edge Detection by Nonlinear Diffusion. II
Álvarez, L., Lions, P., & Morel, J. (1992) · SIAM Journal on Numerical Analysis · doi:10.1137/0729052 · Cited by 2,210 · see citing works
Nonlinear anisotropic filtering of MRI data
Gerig, G., Kübler, O., Kikinis, R., & Jolesz, F. A. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.141646 · Cited by 1,153 · see citing works
The Human Central Nervous System: A Synopsis and Atlas
Nieuwenhuys, R., Voogd, J., & van Huijzen, C. (2012) · Medical Entomology and Zoology · Cited by 543 · see citing works
Kimia, B. B., Tannenbaum, A., & Zucker, S. W. (1995) · International Journal of Computer Vision · doi:10.1007/bf01451741 · Cited by 542 · see citing works
The Human Central Nervous System
Nieuwenhuys, R., Voogd, J., & van Huijzen, C. (1988) · Springer eBooks · doi:10.1007/978-3-662-10343-2 · Cited by 477 · see citing works
Clarke, S., & Judith Miklossy, A. (1990) · The Journal of Comparative Neurology · doi:10.1002/cne.902980205 · Cited by 399 · see citing works
Mangin, J.-F., Frouin, V., Isabelle Bloch, A., R�gis, J., & L�pez-Krahe, J. (1995) · Journal of Mathematical Imaging and Vision · doi:10.1007/bf01250286 · Cited by 354 · see citing works
Self-citationA Computerized Approach for Morphological Analysis of the Corpus Callosum
Davatzikos, C. A., Vaillant, M., Resnick, S. M., Prince, J. L., Letovsky, S. I., & Bryan, R. N. (1996) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199601000-00017 · Cited by 321 · see citing works
Functional Neuroimaging--Technical Foundations
Heather, J. D., & Frackowiak, R. S. J. (1995) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.58.5.647-c · Cited by 292 · see citing works
Biased anisotropic diffusion: a unified regularization and diffusion approach to edge detection
Nordström, K. N. (1990) · Image and Vision Computing · doi:10.1016/0262-8856(90)80008-h · Cited by 254 · see citing works
Hough transform detection of the longitudinal fissure in tomographic head images
Brummer, M. E. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.75613 · Cited by 83 · see citing works
Székely, G., Kelemen, A., Brechbühler, C., et al. (1995) · Lecture notes in computer science · doi:10.1007/978-3-540-49197-2_66 · Cited by 58 · see citing works
Deformable Models for Reconstructing Unstructured 3D Data
Algorri, M.-E., & Schmitt, F. (1995) · Lecture notes in computer science · doi:10.1007/978-3-540-49197-2_53 · Cited by 12 · see citing works
Székely, G., Kelemen, A. G., Brechbühler, C., et al. (2005) · Springer eBooks · doi:10.1007/bfb0034992 · Cited by 9 · see citing works
Deformable models for reconstructing unstructured 3D data
Algorri, M.-E., & Schmitt, F. (2005) · Springer eBooks · doi:10.1007/bfb0034979 · Cited by 2 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Tractography-based connectomes are dominated by false-positive connections
Maier-Hein, K. H., Neher, P., Houde, J.-C., Côté, M.-A., Garyfallidis, E., Zhong, J., Chamberland, M., Yeh, F.-C., Lin, Y.-C., Ji, Q., et al. (2016) · doi:10.1101/084137 · Cited by 1,361 · see citing works
Girard, G., Caminiti, R., Battaglia-Mayer, A., St-Onge, E., Ambrosen, K. S., Eskildsen, S. F., Krug, K., Dyrby, T. B., Descoteaux, M., Thiran, J.-P., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117201 · Cited by 83 · see citing works
- Authors
- Mangin, J.-F., Regis, J., & Frouin, V.
- Affiliations
- Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR)
- Venue
- Proceedings of the Workshop on Mathematical Methods in Biomedical Image Analysis
- Publisher
- IEEE
- Published
- 1996
- Pages
- 319-328
- OpenAlex
- W2071818687
- Cited by
- 27
- References
- 18
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 1 · 2022: 2 · 2020: 2 · 2017: 2 · 2014: 1 · 2013: 1 · 2012: 1
- FWCI
- 0.90
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE Workshop on Mathematical Methods in Biomedical Image Analysis (MMBIA) (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Digital Image Processing Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Cell Image Analysis Techniques
- Keywords
- conservative flows, Dirichlet-Neumann problem, information flow, shape analysis, medical image analysis, corpus callosum, anterior commissure, brainstem, overrelaxation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review