The Smart Transformer: A solid-state transformer tailored to provide ancillary services to the distribution grid
Open accessAbstract
The solid-state transformer (SST) was conceived as a replacement for the conventional power transformer, with both lower volume and weight. The smart transformer (ST) is an SST that provides ancillary services to the distribution and transmission grids to optimize their performance. Hence, the focus shifts from hardware advantages to functionalities. One of the most desired functionalities is the dc connectivity to enable a hybrid distribution system. For this reason, the ST architecture shall be composed of at least two power stages. The standard design procedure for this kind of system is to design each power stage for the maximum load. However, this design approach might limit additional services, like the reactive power compensation on the medium voltage (MV) side, and it does not consider the load regulation capability of the ST on the low voltage (LV) side. If the SST is tailored to the services that it shall provide, different stages will have different designs, so that the ST is no longer a mere application of the SST but an entirely new subject.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Thus, it requires a bulky filter on the DC side which significantly increases the overall cost of MMC [24].”
From State of the Art of Solid-State Transformers: Advanced Topologies, Implementation Issues, Recent Progress and Improvements (2020) · cites this paper as [24]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grid Converters for Photovoltaic and Wind Power Systems
Teodorescu, R., Liserre, M., & Rodríguez, P. (2010) · Wiley eBooks · doi:10.1002/9780470667057 · Cited by 3,399
Self-citationFarhangi, H. (2010) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2009.934876 · Cited by 2,967
Ipakchi, A., & Albuyeh, F. (2009) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2008.931384 · Cited by 1,644
Determining the impact of distributed generation on power systems. I. Radial distribution systems
Barker, P. P., & de Mello, R. W. (2002) · IEEE Power Engineering Society Summer Meeting · doi:10.1109/pess.2000.868775 · Cited by 1,217
Review of Solid-State Transformer Technologies and Their Application in Power Distribution Systems
She, X., Huang, A. Q., & Burgos, R. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2277917 · Cited by 1,164
High‐Frequency Magnetic Components
Kazimierczuk, M. K. (2013) · Wiley eBooks · doi:10.1002/9781118717806 · Cited by 687
Power Electronic Traction Transformer—Medium Voltage Prototype
Zhao, C., Dujic, D., Mester, A., Steinke, J. K., Weiss, M., Lewdeni-Schmid, S., Chaudhuri, T., & Stefanutti, P. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2278960 · Cited by 478
The Smart Transformer: Impact on the Electric Grid and Technology Challenges
Liserre, M., Buticchi, G., Andresen, M., De Carne, G., Costa, L. F., & Zou, Z.-X. (2016) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2016.2551418 · Cited by 445
Self-citationIntegration Issues of Distributed Generation in Distribution Grids
Coster, E., Myrzik, J., Kruimer, B., & Kling, W. L. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2052776 · Cited by 421
Design and Demonstration of a 3.6-kV–120-V/10-kVA Solid-State Transformer for Smart Grid Application
She, X., Yu, X., Wang, F., & Huang, A. Q. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2293471 · Cited by 324
International Industry Practice on Power System Load Modeling
Milanović, J. V., Yamashita, K., Villanueva, S. M., Djokic, S., & Korunovic, L. M. (2012) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2231969 · Cited by 307
Review on Implementation and Assessment of Conservation Voltage Reduction
Wang, Z., & Wang, J. (2014) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2288518 · Cited by 289
Wang, J., Huang, A., Sung, W., Liu, Y., & Baliga, B. (2009) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2009.932583 · Cited by 260
Evaluation of Conservation Voltage Reduction (CVR) on a National Level
Schneider, K. P., Fuller, J., Tuffner, F., & Singh, R. (2010) · doi:10.2172/990131 · Cited by 208
Quad-Active-Bridge DC–DC Converter as Cross-Link for Medium-Voltage Modular Inverters
Costa, L. F., Buticchi, G., & Liserre, M. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2633539 · Cited by 119
Self-citationLoad Control Using Sensitivity Identification by Means of Smart Transformer
Carne, G. D., Buticchi, G., Liserre, M., & Vournas, C. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2614846 · Cited by 110
Self-citationReverse Power Flow Control in a ST-Fed Distribution Grid
Carne, G. D., Buticchi, G., Zou, Z., & Liserre, M. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2651147 · Cited by 109
Self-citationOn-Line Load Sensitivity Identification in LV Distribution Grids
Carne, G. D., Liserre, M., & Vournas, C. D. (2016) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2016.2581979 · Cited by 86
Self-citationAnalysis of the frequency‐based control of a master/slave micro‐grid
Buticchi, G., Carne, G. D., Barater, D., Zou, Z., & Liserre, M. (2016) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2016.0167 · Cited by 40
Self-citationFrequency-Based Overload Control of Smart Transformers
Carne, G. D., Buticchi, G., Liserre, M., & Vournas, C. D. (2015) · doi:10.1109/ptc.2015.7232798 · Cited by 22
Self-citationDistribution transformer size optimization by forecasting customer electricity load
Luze, J. D. (2009) · IEEE Rural Electric Power Conference (REPC) · doi:10.1109/repcon.2009.4919426 · Cited by 11
Research Challenges and Future Perspectives of Solid-State Transformer Technology
Kolar, J. W., Huber, J., Guillod, T., Rothmund, D., & Krismer, F. (2015) · International Conference on Power Engineering, Energy and Electrical Drives · Cited by 4
Flagged first, then by citations
1 of the 23 references couldn’t be matched to a known paper.
Research works printed but not linked: 2
- drofenik, 2005, Theoretical converter power density limits for forced convection cooling, Proc Int Conf Power Conversion Intelligent Motion, 608
- 0, Nasdaq Copper latest price and chart for high grade copper
Cited by
Sorted by citations
Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
“In contrast to CHB, MMC has a complex control system, however, it provides the DC link for the connection ofMVDC loads sources.”
BackgroundInfluentialPower Electronics Technology for Large-Scale Renewable Energy Generation
Blaabjerg, F., Yang, Y., Kim, K. A., & Rodríguez, J. (2023) · Proceedings of the IEEE · doi:10.1109/jproc.2023.3253165 · Cited by 337
Islam, M. R., Mahfuz-Ur-Rahman, A. M., Muttaqi, K. M., & Sutanto, D. (2018) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2018.2878885 · Cited by 178
Zheng, L., Marellapudi, A., Chowdhury, V. R., Bilakanti, N., Kandula, R. P., Saeedifard, M., Grijalva, S., & Divan, D. M. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2022.3144361 · Cited by 148
Costa, L. F., & Liserre, M. (2018) · IEEE Power Electronics Magazine · doi:10.1109/mpel.2018.2874345 · Cited by 133
Self-citation
Metadata
- Authors
- Ferreira Costa, L., De Carne, G., Buticchi, G., & Liserre, M.
- Affiliations
- Christian-Albrechts-Universität zu Kiel (DE)
- Venue
- IEEE Power Electronics Magazine
- Published
- 2017-06
- Volume
- 4
- Issue
- 2
- Pages
- 56-67
- ISSN
- 2329-9207 (ISSN-L)
- 2329-9215
- OpenAlex
- W2669566973
- Cited by
- 303
- References
- 23
- Citations by year
- 2026: 15 · 2025: 32 · 2024: 27 · 2023: 38 · 2022: 37 · 2021: 49 · 2020: 33 · 2019: 36 · 2018: 31 · 2017: 5
- FWCI
- 11.94
- Type
- journal article
- Language
- en
- Open access
- green
- macau.uni-kiel.de
- Locations
- IEEE Power Electronics Magazine (publishedVersion)
- Multimedialen Archiv und Publikationsserver der Christian-Albrechts-Universität zu Kiel (Christian-Albrechts-Universität zu Kiel) (submittedVersion)
- Multimedialen Archiv und Publikationsserver der Christian-Albrechts-Universität zu Kiel (Christian-Albrechts-Universität zu Kiel) (submittedVersion, other-oa)
- Funders
- European Commission (2007–2013, FP/2007/2013)
- FP7 Ideas: European Research Council (616344)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Keywords
- solid-state transformer, ancillary services, distribution networks, two-stage power converter, reactive power compensation, load regulation, power stage design, medium voltage, low voltage
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review