The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Understanding Power System Hannonics
Abstract
Harmonics – Past to Present Power systems are designed to operate at frequencies of 50 or 60Hz. However, certain types of loads produce currents and voltages with frequencies that are integer multiples of the 50 or 60 Hz fundamental frequency. These higher frequencies are a form of electrical pollution known as power system harmonics. Power system harmonics are not a new phenomenon. Concern over harmonic distortion has ebbed and flowed during the history of electric power systems. Steinmetz published a book in 1916 that devoted considerable attention to the study of harmonics in three-phase power systems. His main concern was third harmonic currents caused by saturated iron in transformers and machines, and he was the first to propose delta connections for blocking third harmonic currents. Later, with the advent of rural electrification and telephone service, power and telephone circuits were often placed on common rights-of-way. Harmonic currents produced by transformer magnetizing currents caused inductive interference with open-wire telephone systems. The interference was so severe at times that voice communication was impossible. This problem was studied and alleviated by filtering and by placing design limits on transformer magnetizing currents. Today, the most common sources of harmonics are power electronic loads such as adjustable-speed drives (ASDs) and switch-mode power supplies. These loads use diodes, silicon-controlled rectifiers (SCRs), power transistors, and other electronic switches to chop waveforms to control power or to convert 50/60Hz AC to DC. In the case of ASDs, the DC is then converted to variable-frequency AC to control motor speed. Example uses of ASDs include chillers and pumps. Due to tremendous advantages in efficiency and controllability, power electronic loads are proliferating and can be found at all power levels – from low voltage appliances to high voltage converters. Hence, power systems harmonics are once again an important problem.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical power systems quality
(1996) · Choice Reviews Online · doi:10.5860/choice.34-0322 · Cited by 2,608
Arrillaga, J., & Watson, N. R. (2003) · Wiley eBooks · doi:10.1002/0470871229 · Cited by 1,651
Harmonic Reduction In Group-Connected Generators-HVDC Convertor
Arrillaga, J., Yonghe, L., Crimp, C. S., & Villablanca, M. (2005) · ICHPS V International Conference on Harmonics in Power Systems. · doi:10.1109/ichps.1992.559037 · Cited by 365
Sallam, A. A., & Malik, O. P. (2011) · Wiley eBooks · doi:10.1002/9780470943854.ch7 · Cited by 139
Cited by
Neural-Network-Based Signature Recognition for Harmonic Source Identification
Srinivasan, D., Ng, W. S., & Liew, A. C. (2006) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2005.852370 · Cited by 453
Metadata
- Authors
- Grady, W. M., & Santoso, S.
- Venue
- IEEE Power Engineering Review
- Published
- 2001-11
- Volume
- 21
- Issue
- 11
- Pages
- 8-11
- ISSN
- 0272-1724 (ISSN-L)
- OpenAlex
- W2072266833
- Cited by
- 273
- References
- 4
- FWCI
- 2.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Understanding Power System Hannonics. https://app.cochat.ai/papers/10.1109/mper.2001.961997
- The paper
- Grady, W. M., & Santoso, S. (2001). Understanding Power System Hannonics. IEEE Power Engineering Review. https://doi.org/10.1109/mper.2001.961997
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.