The DOI matches its Crossref record.
Super-resolution image reconstruction: a technical overview
Abstract
A new approach toward increasing spatial resolution is required to overcome the limitations of the sensors and optics manufacturing technology. One promising approach is to use signal processing techniques to obtain an high-resolution (HR) image (or sequence) from observed multiple low-resolution (LR) images. Such a resolution enhancement approach has been one of the most active research areas, and it is called super resolution (SR) (or HR) image reconstruction or simply resolution enhancement. In this article, we use the term "SR image reconstruction" to refer to a signal processing approach toward resolution enhancement because the term "super" in "super resolution" represents very well the characteristics of the technique overcoming the inherent resolution limitation of LR imaging systems. The major advantage of the signal processing approach is that it may cost less and the existing LR imaging systems can be still utilized. The SR image reconstruction is proved to be useful in many practical cases where multiple frames of the same scene can be obtained, including medical imaging, satellite imaging, and video applications. The goal of this article is to introduce the concept of SR algorithms to readers who are unfamiliar with this area and to provide a review for experts. To this purpose, we present the technical review of various existing SR methodologies which are often employed. Before presenting the review of existing SR algorithms, we first model the LR image acquisition process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Image super-resolution: the techniques, applications, and future
Yue, L., Shen, H., Li, J., Yuan, Q., Zhang, H., & Zhang, L. (2016) · Signal Processing · doi:10.1016/j.sigpro.2016.05.002 · Cited by 554
Super‐resolution musculoskeletal MRI using deep learning
Chaudhari, A. S., Fang, Z., Kogan, F., Wood, J., Stevens, K. J., Gibbons, E. K., Lee, J. H., Gold, G. E., & Hargreaves, B. A. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27178 · Cited by 406
Deep Network Cascade for Image Super-resolution
Cui, Z., Chang, H., Shan, S., Zhong, B., & Chen, X. (2014) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-10602-1_4 · Cited by 255
Okolie, C. J., & Smit, J. L. (2022) · ISPRS Journal of Photogrammetry and Remote Sensing · doi:10.1016/j.isprsjprs.2022.03.016 · Cited by 139
Technical and clinical overview of deep learning in radiology
Ueda, D., Shimazaki, A., & Miki, Y. (2019) · Japanese Journal of Radiology · doi:10.1007/s11604-018-0795-3 · Cited by 100
Metadata
- Authors
- Park, S. C., Park, M. K., & Kang, M. G.
- Venue
- IEEE Signal Processing Magazine
- Published
- 2003-05
- Volume
- 20
- Issue
- 3
- Pages
- 21-36
- ISSN
- 1053-5888 (ISSN-L)
- OpenAlex
- W2067042811
- Cited by
- 3,282
- References
- 0
- FWCI
- 67.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Super-resolution image reconstruction: a technical overview. https://app.cochat.ai/papers/10.1109/msp.2003.1203207
- The paper
- Park, S. C., Park, M. K., & Kang, M. G. (2003). Super-resolution image reconstruction: a technical overview. IEEE Signal Processing Magazine. https://doi.org/10.1109/msp.2003.1203207
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.