The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Optimization Methods for Magnetic Resonance Image Reconstruction: Key Models and Optimization Algorithms
Open accessAbstract
The development of compressed sensing methods for magnetic resonance (MR) image reconstruction led to an explosion of research on models and optimization algorithms for MR imaging (MRI). Roughly 10 years after such methods first appeared in the MRI literature, the U.S. Food and Drug Administration (FDA) approved certain compressed sensing methods for commercial use, making compressed sensing a clinical success story for MRI. This review paper summarizes several key models and optimization algorithms for MR image reconstruction, including both the type of methods that have FDA approval for clinical use, as well as more recent methods being considered in the research community that use data-adaptive regularizers. Many algorithms have been devised that exploit the structure of the system model and regularizers used in MRI; this paper strives to collect such algorithms in a single survey.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boyd, S., Parikh, N., Chu, E., Peleato, B., & Eckstein, J. (2011) · Foundations and Trends® in Machine Learning · doi:10.1561/2200000016 · Cited by 17,075
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Magnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577 · cited 1×
“Quantifying tissue properties using nonlinear models is a rich topic of its own [5], but we focus here on the problem of reconstructing images of the transverse magnetization from MR measurements.”
BackgroundPlug-and-Play ADMM for Image Restoration: Fixed-Point Convergence and Applications
Chan, S. H., Wang, X., & Elgendy, O. A. (2017) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2016.2629286 · Cited by 904
Cited by
Yaman, B., Hosseini, S. A. H., Moeller, S., Ellermann, J., Uğurbil, K., & Akçakaya, M. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28378 · Cited by 327
Plug-and-Play Methods for Magnetic Resonance Imaging: Using Denoisers for Image Recovery
Ahmad, R., Bouman, C. A., Buzzard, G. T., Chan, S., Liu, S., Reehorst, E. T., & Schniter, P. (2020) · IEEE Signal Processing Magazine · doi:10.1109/msp.2019.2949470 · Cited by 261
Implicit data crimes: Machine learning bias arising from misuse of public data
Shimron, E., Tamir, J. I., Wang, K., & Lustig, M. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2117203119 · Cited by 112
Metadata
- Authors
- Fessler, J. A.
- Venue
- IEEE Signal Processing Magazine
- Published
- 2020-01
- Volume
- 37
- Issue
- 1
- Pages
- 33-40
- ISSN
- 1053-5888 (ISSN-L)
- 1558-0792
- OpenAlex
- W2999167634
- Cited by
- 188
- References
- 4
- FWCI
- 13.67
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimization Methods for Magnetic Resonance Image Reconstruction: Key Models and Optimization Algorithms. https://app.cochat.ai/papers/10.1109/msp.2019.2943645
- The paper
- Fessler, J. A. (2020). Optimization Methods for Magnetic Resonance Image Reconstruction: Key Models and Optimization Algorithms. IEEE Signal Processing Magazine. https://doi.org/10.1109/msp.2019.2943645
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.