The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Deep-Learning Methods for Parallel Magnetic Resonance Imaging Reconstruction: A Survey of the Current Approaches, Trends, and Issues
Open accessAbstract
Following the success of deep learning in a wide range of applications, neural network-based machine learning techniques have received interest as a means of accelerating magnetic resonance imaging (MRI). A number of ideas inspired by deep learning techniques from computer vision and image processing have been successfully applied to non-linear image reconstruction in the spirit of compressed sensing for both low dose computed tomography and accelerated MRI. The additional integration of multi-coil information to recover missing k-space lines in the MRI reconstruction process, is still studied less frequently, even though it is the de-facto standard for currently used accelerated MR acquisitions. This manuscript provides an overview of the recent machine learning approaches that have been proposed specifically for improving parallel imaging. A general background introduction to parallel MRI is given that is structured around the classical view of image space and k-space based methods. Both linear and non-linear methods are covered, followed by a discussion of recent efforts to further improve parallel imaging using machine learning, and specifically using artificial neural networks. Image-domain based techniques that introduce improved regularizers are covered as well as k-space based methods, where the focus is on better interpolation strategies using neural networks. Issues and open problems are discussed as well as recent efforts for producing open datasets and benchmarks for the community.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
ImageNet: A large-scale hierarchical image database
Deng, J., Dong, W., Socher, R., Li, L.-J., Li, K., & Fei-Fei, L. (2009) · 2009 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2009.5206848 · Cited by 65,333
Image-to-Image Translation with Conditional Adversarial Networks
Isola, P., Zhu, J.-Y., Zhou, T., & Efros, A. A. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.632 · Cited by 22,930
Beyond a Gaussian Denoiser: Residual Learning of Deep CNN for Image Denoising
Zhang, K., Zuo, W., Chen, Y., Meng, D., & Zhang, L. (2017) · IEEE Transactions on Image Processing · doi:10.1109/tip.2017.2662206 · Cited by 8,983
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Self-citationLearning a variational network for reconstruction of accelerated MRI data
Hammernik, K., Klatzer, T., Kobler, E., Recht, M. P., Sodickson, D. K., Pock, T., & Knoll, F. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26977 · Cited by 1,713
Self-citationImage reconstruction by domain-transform manifold learning
Zhu, B., Liu, J. Z., Cauley, S. F., Rosen, B. R., & Rosen, M. S. (2018) · Nature · doi:10.1038/nature25988 · Cited by 1,694
ESPIRiT—an eigenvalue approach to autocalibrating parallel MRI: Where SENSE meets GRAPPA
Uecker, M., Lai, P., Murphy, M. J., Virtue, P., Elad, M., Pauly, J. M., Vasanawala, S. S., & Lustig, M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24751 · Cited by 1,392
A deep cascade of convolutional neural networks for dynamic MR image reconstruction
Schlemper, J., Caballero, J., Hajnal, J. V., Price, A. N., & Rueckert, D. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2760978 · Cited by 1,338
Advances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211
MoDL: Model-Based Deep Learning Architecture for Inverse Problems
Aggarwal, H. K., Mani, M. P., & Jacob, M. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2865356 · Cited by 1,069
Block, K. T., Uecker, M., & Frahm, J. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21236 · Cited by 824
SPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐space
Lustig, M., & Pauly, J. M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22428 · Cited by 822
k‐t FOCUSS: A general compressed sensing framework for high resolution dynamic MRI
Jung, H., Sung, K., Nayak, K. S., Kim, E. Y., & Ye, J. C. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21757 · Cited by 669
Second order total generalized variation (TGV) for MRI
Knoll, F., Bredies, K., Pock, T., & Stollberger, R. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22595 · Cited by 634
Self-citationEo, T., Jun, Y., Kim, T., Jang, J., Lee, H., & Hwang, D. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27201 · Cited by 455
Robson, P. M., Grant, A. K., Madhuranthakam, A. J., Lattanzi, R., Sodickson, D. K., & McKenzie, C. A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21728 · Cited by 438
Self-citationKnoll, F., Zbontar, J., Sriram, A., Muckley, M. J., Bruno, M., Defazio, A., Parente, M., Geras, K. J., Katsnelson, J., Chandarana, H., et al. (2020) · Radiology: Artificial Intelligence · doi:10.1148/ryai.2020190007 · Cited by 409
Self-citationCalibrationless parallel imaging reconstruction based on structured low-rank matrix completion
Shin, P. J., Larson, P. E. Z., Ohliger, M. A., Elad, M., Pauly, J. M., Vigneron, D. B., & Lustig, M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24997 · Cited by 391
Akçakaya, M., Moeller, S., Weingärtner, S., & Uğurbil, K. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27420 · Cited by 391
Self-citation${k}$ -Space Deep Learning for Accelerated MRI
Han, Y., Sunwoo, L., & Ye, J. C. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2927101 · Cited by 344
Array compression for MRI with large coil arrays
Buehrer, M., Pruessmann, K. P., Boesiger, P., & Kozerke, S. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21237 · Cited by 257
Jin, K. H., Lee, D., & Ye, J. C. (2016) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2016.2601296 · Cited by 245
Knoll, F., Hammernik, K., Kobler, E., Pock, T., Recht, M. P., & Sodickson, D. K. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27355 · Cited by 217
Self-citationP‐LORAKS: Low‐rank modeling of local k‐space neighborhoods with parallel imaging data
Haldar, J. P., & Zhuo, J. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25717 · Cited by 198
A parallel MR imaging method using multilayer perceptron
Kwon, K., Kim, D., & Park, H. (2017) · Medical Physics · doi:10.1002/mp.12600 · Cited by 164
Akçakaya, M., Basha, T., Goddu, B., Goepfert, L. A., Kissinger, K. V., Tarokh, V., Manning, W. J., & Nezafat, R. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22841 · Cited by 148
Parallel imaging with nonlinear reconstruction using variational penalties
Knöll, F., Clason, C., Bredies, K., Uecker, M., & Stollberger, R. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22964 · Cited by 102
Akçakaya, M., Basha, T., Chan, R. H. M., Manning, W. J., & Nezafat, R. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24683 · Cited by 82
Sparsity-Promoting Calibration for GRAPPA Accelerated Parallel MRI Reconstruction
Weller, D. S., Polimeni, J. R., Grady, L. J., Wald, L. L., Elfar Adalsteinsson, A., & Goyal, V. K. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2256923 · Cited by 77
Jun, Y., Eo, T., Shin, H., Kim, T., Lee, H., & Hwang, D. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27656 · Cited by 26
Accelerated Coronary Mri Using 3D Spirit-Raki With Sparsity Regularization
Hosseini, S. A. H., Moeller, S., Weingärtner, S., Uǧurbil, K., & Akçakaya, M. (2019) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2019.8759459 · Cited by 19
Self-citationAccelerated Simultaneous Multi-Slice MRI using Subject-Specific Convolutional Neural Networks
Zhang, C., Moeller, S., Weingärtner, S., Uǧurbil, K., & Akçakaya, M. (2018) · Asilomar Conference on Signals, Systems and Computers (ACSSC) · doi:10.1109/acssc.2018.8645313 · Cited by 10
Self-citation
Cited by
Deep Learning Techniques for Inverse Problems in Imaging
Ongie, G., Jalal, A., Metzler, C. A., Baraniuk, R. G., Dimakis, A. G., & Willett, R. (2020) · IEEE Journal on Selected Areas in Information Theory · doi:10.1109/jsait.2020.2991563 · Cited by 577
Yaman, B., Hosseini, S. A. H., Moeller, S., Ellermann, J., Uğurbil, K., & Akçakaya, M. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28378 · Cited by 327
Self-citationResults of the 2020 fastMRI challenge for machine learning MR image reconstruction
Muckley, M. J., Riemenschneider, B., Radmanesh, A., Kim, S., Jeong, G., Ko, J., Jun, Y., Shin, H., Hwang, D., Mostapha, M., et al. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3075856 · Cited by 313
Self-citationGuo, P., Wang, P., Zhou, J., Jiang, S., & Patel, V. M. (2021) · 2021 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr46437.2021.00245 · Cited by 193
Implicit data crimes: Machine learning bias arising from misuse of public data
Shimron, E., Tamir, J. I., Wang, K., & Lustig, M. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2117203119 · Cited by 112
Metadata
- Authors
- Knoll, F., Hammernik, K., Zhang, C., Moeller, S., Pock, T., Sodickson, D. K., & Akcakaya, M.
- Venue
- IEEE Signal Processing Magazine
- Published
- 2020-01
- Volume
- 37
- Issue
- 1
- Pages
- 128-140
- ISSN
- 1053-5888 (ISSN-L)
- 1558-0792
- OpenAlex
- W3001554227
- Cited by
- 403
- References
- 37
- FWCI
- 25.55
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.