Low-cost differential front-end for Doppler radar vital sign monitoring
Open accessThe DOI matches its Crossref record.
Abstract
We present a differential front end design for improving the performance of short-range low-cost Doppler radars for vital sign detection with application to automotive driver safety systems, health monitoring, and security screening. By using dual helical antennas each with a 40-degree beamwidth, it is possible to illuminate the body in two adjacent locations to perform a differential measurement. Since only one of the beams illuminates the heart, the baseband signal from the second radar is used for motion cancellation. We demonstrate this approach using a custom-designed dual helical antenna and simple direct-conversion radar circuits implemented in microstrip operating at 2.460 GHz and 2.510 GHz., respectively. Heart rate data is shown for detection distances of 0.5 meter showing reduction in background motion noise compared to data from traditional single radar unit design.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Smart Homes that Monitor Breathing and Heart Rate
Adib, F., Mao, H., Kabelac, Z., Katabi, D., & Miller, R. C. (2015) · Proceedings of the 33rd Annual ACM Conference on Human Factors in Computing Systems · doi:10.1145/2702123.2702200 · Cited by 916
“Past proposals use one of the following techniques: Doppler radar [17, 16, 15], WiFi [34, 27], or ultra-wideband radar [48, 14, 7].”
BackgroundMethodA Review on Recent Advances in Doppler Radar Sensors for Noncontact Healthcare Monitoring
Li, C., Lubecke, V. M., Boric-Lubecke, O., & Lin, J. (2013) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2013.2256924 · Cited by 821
Emotion recognition using wireless signals
Zhao, M., Adib, F., & Katabi, D. (2016) · Proceedings of the 22nd Annual International Conference on Mobile Computing and Networking · doi:10.1145/2973750.2973762 · Cited by 461
“Our work is closest to prior art that uses RF signals to extract a person’s breathing rate and average heart rate [19, 20, 25, 45, 31, 19, 20, 25, 45, 31, 63, 17, 7].”
BackgroundResultNon-contact heart rate and heart rate variability measurements: A review
Kranjec, J., Beguš, S., Geršak, G., & Drnovšek, J. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2014.03.004 · Cited by 318
EM-Wave Biosensors: A Review of RF, Microwave, mm-Wave and Optical Sensing
Mehrotra, P., Chatterjee, B., & Sen, S. (2019) · Sensors · doi:10.3390/s19051013 · Cited by 219
“A differential front end Doppler radar is proposed in [41] which illuminates the body in two adjacent locations and are based on the fact that since only one of the beams illuminates the heart, the other can be used for motion cancellation.”
BackgroundHuman Vital Signs Detection Methods and Potential Using Radars: A Review
Kebe, M., Gadhafi, R., Mohammad, B., Sanduleanu, M., Saleh, H., & Al-Qutayri, M. (2020) · Sensors · doi:10.3390/s20051454 · Cited by 205
“A simple direct‐ conversion radar with very narrow beam dual helical antennas was designed in [132] for automotive application.”
Signal-to-Noise Ratio in Doppler Radar System for Heart and Respiratory Rate Measurements
Droitcour, A. D., Boric-Lubecke, O., & Kovacs, G. T. A. (2009) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2009.2029668 · Cited by 162
“While multiple antenna systems [6], [ 7 ] andadvancedsignalprocessing[26]havebeenexploredtoovercome this limitation, random motion is still a challenging issue beyond the scope of this paper.”
Background
Metadata
- Authors
- Fletcher, R., & Han, J.
- Venue
- 2009 IEEE MTT-S International Microwave Symposium Digest
- Publisher
- IEEE
- Published
- 2009-06
- Pages
- 1325-1328
- ISSN
- 0149-645X (ISSN-L)
- OpenAlex
- W2134363656
- Cited by
- 104
- References
- 0
- FWCI
- 12.52
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.