Building a SCADA Security Testbed
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
SCADA (supervisory control and data acquisition) systems control and monitor industrial and critical infrastructure functions, such as the electricity, gas, water, waste, railway and traffic. Recent attacks on SCADA systems highlight the need of a SCADA security testbed, which can be used to model real SCADA systems and study the effects of attacks on them. We propose the architecture of a modular SCADA testbed and describe our tool which mimics a SCADA network, monitors and controls real sensors and actuators using Modbus/TCP protocol. Using distributed denial of service (DDoS) scenarios we show how attackers can disrupt the operation of a SCADA system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Security for Industrial Communication Systems
Dzung, D., Naedele, M., Von Hoff, T. P., & Crevatin, M. (2005) · Proceedings of the IEEE · doi:10.1109/jproc.2005.849714 · Cited by 386
Intrusion Detection and Event Monitoring in SCADA Networks
Oman, P., & Phillips, M. (2007) · IFIP International Federation for Information Processing · doi:10.1007/978-0-387-75462-8_12 · Cited by 62
Cited by
Cybersecurity for industrial control systems: A survey
Bhamare, D., Zolanvari, M., Erbad, A., Jain, R., Khan, K., & Meskin, N. (2020) · Computers & Security · doi:10.1016/j.cose.2019.101677 · Cited by 394
A survey of cyber security management in industrial control systems
Knowles, W., Prince, D., Hutchison, D., Disso, J. F. P., & Jones, K. (2015) · International Journal of Critical Infrastructure Protection · doi:10.1016/j.ijcip.2015.02.002 · Cited by 344
“[165] propose a different hybrid approach that uses Lego Mindstorms NXT hardware kits to mimic programmable logic controller functionality; their testbed also uses OMNET++ for discrete event simulation and supports the Modbus/TCP protocol.”
MethodA Survey on SCADA Systems: Secure Protocols, Incidents, Threats and Tactics
Pliatsios, D., Sarigiannidis, P., Lagkas, T., & Sarigiannidis, A. G. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2020.2987688 · Cited by 320
“Authors in [70] proposed a modular SCADA testbed based on the Modbus protocol.”
MethodGenge, B., Siaterlis, C., Nai Fovino, I., & Masera, M. (2012) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2012.06.015 · Cited by 82
“For cyber layer implementations the following approaches were found: only real components (Nai Fovino [8], Davis [12]); real components combined with simulated ones (Chunlei [7], Queiroz [9], McDonald [14]); and only simulated components (Chabukswar [10], Hopkinson [11]).”
BackgroundMethodInfluentialA testbed for SCADA control system cybersecurity research and pedagogy
Morris, T., Vaughn, R., & Dandass, Y. S. (2011) · Proceedings of the Seventh Annual Workshop on Cyber Security and Information Intelligence Research · doi:10.1145/2179298.2179327 · Cited by 76
Metadata
- Authors
- Queiroz, C., Mahmood, A., Hu, J., Tari, Z., & Yu, X.
- Venue
- 2009 Third International Conference on Network and System Security
- Publisher
- IEEE
- Published
- 2009
- Pages
- 357-364
- OpenAlex
- W2123883345
- Cited by
- 90
- References
- 2
- FWCI
- 8.95
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Building a SCADA Security Testbed. https://app.cochat.ai/papers/10.1109/nss.2009.82
- The paper
- Queiroz, C., Mahmood, A., Hu, J., Tari, Z., & Yu, X. (2009). Building a SCADA Security Testbed. 2009 Third International Conference on Network and System Security. https://doi.org/10.1109/nss.2009.82
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.