Systematic and Distributed Time-of-Flight List Mode PET Reconstruction
The DOI matches its Crossref record.
Abstract
Philips has recently released the time-of-flight (TOF) PET/CT GEMINI-TF scanner. It uses 4 times 4 times 22 mm3LYSO crystals, which has 600 ps timing resolution, 12% energy resolution and 4.8 mm spatial resolution. This paper describes the system design and general approach of TOF reconstruction in Philips' GEMINI-TF scanner. A relaxed list mode ordered subset expectation maximization (LMOSEM) algorithm is used in the reconstruction, with chronologically ordered subsets. The sensitivity and emission object in LMOSEM are computed in the spherically symmetric basis function (blob) space. The multiplicative correction factors of detector normalization, isotope decay, system dead-time and crystal timing are pre-corrected for each list mode event. Attenuation, scatter and randoms are corrected in the reconstruction system matrix. A TOF-dependent single scatter simulation (SSS) is implemented for TOF scatter estimation. To accelerate reconstruction, the sensitivity calculation and list mode reconstruction are distributed to multiple processors, using a dynamic load balancing scheme. For this paper, a uniform cylinder phantom with cold and hot cylinder inserts, a NEMA body IEC phantom and a patient study are reconstructed with both TOF and non-TOF reconstructions. We have demonstrated that TOF reconstruction converges faster than non-TOF, and controls noise well than non-TOF. It has better contrast-noise trade-offs than non-TOF for cold regions and small hot lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Benefit of Time-of-Flight in PET: Experimental and Clinical Results
Karp, J. S., Surti, S., Daube-Witherspoon, M. E., & Muehllehner, G. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.044834 · Cited by 584
Self-citationRecent developments in time-of-flight PET
Vandenberghe, S., Mikhaylova, E., D’Hoe, E., Mollet, P., & Karp, J. S. (2016) · EJNMMI Physics · doi:10.1186/s40658-016-0138-3 · Cited by 368
Self-citationFocus on time-of-flight PET: the benefits of improved time resolution
Conti, M. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1711-y · Cited by 335
Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data
Schulz, V., Torres-Espallardo, I., Renisch, S., Hu, Z., Ojha, N., Börnert, P., Perkuhn, M., Niendorf, T., Schäfer, W. M., Brockmann, H., et al. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1603-1 · Cited by 292
Self-citationState of the art and challenges of time-of-flight PET
Conti, M. (2009) · Physica Medica · doi:10.1016/j.ejmp.2008.10.001 · Cited by 274
Metadata
- Authors
- Wang, W., Hu, Z., Gualtieri, E. E., Parma, M. J., Walsh, E. S., Sebok, D., Hsieh, Y.-L., Tung, C.-H., Song, X., Griesmer, J. J., Kolthammer, J. A., Popescu, L. M., Werner, M., Karp, J. S., & Gagnon, D.
- Venue
- 2006 IEEE Nuclear Science Symposium Conference Record
- Publisher
- IEEE
- Published
- 2006
- Pages
- 1715-1722
- ISSN
- 1095-7863 (ISSN-L)
- OpenAlex
- W2115786672
- Cited by
- 95
- References
- 0
- FWCI
- 11.18
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Systematic and Distributed Time-of-Flight List Mode PET Reconstruction. https://app.cochat.ai/papers/10.1109/nssmic.2006.354229
- The paper
- Wang, W., Hu, Z., Gualtieri, E. E., Parma, M. J., Walsh, E. S., Sebok, D., Hsieh, Y.-L., Tung, C.-H., Song, X., Griesmer, J. J., Kolthammer, J. A., Popescu, L. M., Werner, M., Karp, J. S., & Gagnon, D. (2006). Systematic and Distributed Time-of-Flight List Mode PET Reconstruction. 2006 IEEE Nuclear Science Symposium Conference Record. https://doi.org/10.1109/nssmic.2006.354229
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.