The DOI matches its Crossref record.
The digital Silicon Photomultiplier — A novel sensor for the detection of scintillation light
Abstract
We developed a fully digital Silicon Photomultiplier (dSiPM) of 3.8 mm × 3.3 mm in size containing 8188 individual Geiger-mode cells. Each detected photon is directly converted into a digital signal in each of the Geiger-mode cells of the sensor. In addition, the complete trigger logic and a time-to-digital converter are integrated into the sensor. To show the performance of the sensor, LYSO crystals of different sizes were coupled to the sensor. The coincidence timing resolution for 3 mm × 3 mm × 5 mm LYSO crystals using a22Na source amounts to 153 ps FWHM. The energy resolution at 511 keV was determined to be 10.7 % for 4 mm × 4 mm × 22 mm crystals. It is shown that saturation correction can be done without prior need for sensor calibration. The temperature dependence of the photon detection efficiency was found to be -0.6 %/°C including the temperature variation of the light output of LYSO.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Focus on time-of-flight PET: the benefits of improved time resolution
Conti, M. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1711-y · Cited by 335
The digital silicon photomultiplier — Principle of operation and intrinsic detector performance
Frach, T., Prescher, G., Degenhardt, C., de Gruyter, R., Schmitz, A., & Ballizany, R. (2009) · 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) · doi:10.1109/nssmic.2009.5402143 · Cited by 317
Self-citationHistory and future technical innovation in positron emission tomography
Jones, T., & Townsend, D. (2017) · Journal of Medical Imaging · doi:10.1117/1.jmi.4.1.011013 · Cited by 303
Performance Evaluation of the Vereos PET/CT System According to the NEMA NU2-2012 Standard
Rausch, I., Ruiz, A., Valverde-Pascual, I., Cal-González, J., Beyer, T., & Carrio, I. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.215541 · Cited by 168
Update on latest advances in time-of-flight PET
Surti, S., & Karp, J. S. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.10.031 · Cited by 96
Metadata
- Authors
- Dege, C., Prescher, G., Frach, T., Thon, A., de Gruyter, R., Schmitz, A., & Ballizany, R.
- Venue
- 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC)
- Publisher
- IEEE
- Published
- 2009-10
- Pages
- 2383-2386
- ISSN
- 1095-7863 (ISSN-L)
- OpenAlex
- W2131304940
- Cited by
- 169
- References
- 0
- FWCI
- 31.38
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The digital Silicon Photomultiplier — A novel sensor for the detection of scintillation light. https://app.cochat.ai/papers/10.1109/nssmic.2009.5402190
- The paper
- Dege, C., Prescher, G., Frach, T., Thon, A., de Gruyter, R., Schmitz, A., & Ballizany, R. (2009). The digital Silicon Photomultiplier — A novel sensor for the detection of scintillation light. 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC). https://doi.org/10.1109/nssmic.2009.5402190
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.