Performance evaluation of a prototype Positron Emission Tomography scanner using Digital Photon Counters (DPC)
The DOI matches its Crossref record.
Abstract
We show performance results of a prototype Positron Emission Tomography scanner based on digital SiPMs, or Digital Photon Counters (DPC), developed by the Philips Digital Photon Counting unit. The scalability of the DPC technology is demonstrated by an excellent system coincidence timing resolution of 266 ps FWHM and an energy resolution of 10.7 % FWHM. Even while using 4 mm × 4 mm × 22 mm LYSO crystals, the spatial resolution is close to 2.4 mm. Although not optimized yet, the image homogeneity is 5.8 %. We show that the system performance is maintained even at highest count rates encountered in PET scans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cherry, S. R., Jones, T., Karp, J. S., Qi, J., Moses, W. W., & Badawi, R. D. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.184028 · Cited by 763
“Concurrently, the University of Pennsylvania is designing a second prototype total-body system based on digital silicon photomultipliers (27,28) to evaluate the benefits of even better timing resolution in the total-body geometry.”
BackgroundThe silicon photomultiplier: fundamentals and applications of a modern solid-state photon detector
Gundacker, S., & Heering, A. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab7b2d · Cited by 237
Quantification, improvement, and harmonization of small lesion detection with state-of-the-art PET
van der Vos, C. S., Koopman, D., Rijnsdorp, S., Arends, A. J., Boellaard, R., van Dalen, J. A., Lubberink, M., Willemsen, A. T. M., & Visser, E. P. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3727-z · Cited by 206
Krishnamoorthy, S., Blankemeyer, E., Mollet, P., Surti, S., Van Holen, R., & Karp, J. S. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aacec3 · Cited by 141
“…available from a number of vendors, and is used in a number of imaging applications, including pre-clinical systems for PET (Kwon et al., 2011, Degenhardt et al., 2012) and PET-MR (Wehner et al., 2015), as well as commercial whole-body PET scanners (Kwon et al., 2011, Miller et al., 2015, Hsu…”
BackgroundComparison of image quality and lesion detection between digital and analog PET/CT
López-Mora, D. A., Flotats, A., Fuentes-Ocampo, F., Camacho, V., Fernández, A., Ruiz, A., Duch, J., Sizova, M., Domènech, A., Estorch, M., et al. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-4260-z · Cited by 94
“It has been suggested that image quality and detection capability of digital PET/CT is higher due to better spatial and timing resolutions, lower dead time and dynamic count rate range [1, 3, 4, 7].”
Background
Metadata
- Authors
- Degenhardt, C., Rodrigues, P., Trindade, A., Zwaans, B., Mülhens, O., Dorscheid, R., Thon, A., Salomon, A., & Frach, T.
- Venue
- 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC)
- Publisher
- IEEE
- Published
- 2012-10
- Pages
- 2820-2824
- OpenAlex
- W2544172070
- Cited by
- 47
- References
- 0
- FWCI
- 11.65
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.