The silicon photomultiplier: fundamentals and applications of a modern solid-state photon detector
Open accessThe DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
The silicon photomultiplier (SiPM) is an established device of choice for a variety of applications, e.g. in time of flight positron emission tomography (TOF-PET), lifetime fluorescence spectroscopy, distance measurements in LIDAR applications, astrophysics, quantum-cryptography and related applications as well as in high energy physics (HEP). To fully utilize the exceptional performances of the SiPM, in particular its sensitivity down to single photon detection, the dynamic range and its intrinsically fast timing properties, a qualitative description and understanding of the main SiPM parameters and properties is necessary. These analyses consider the structure and the electrical model of a single photon avalanche diode (SPAD) and the integration in an array of SPADs, i.e. the SiPM. The discussion will include the front-end readout and the comparison between analog-SiPMs, where the array of SPADs is connected in parallel, and the digital SiPM, where each SPAD is read out and digitized by its own electronic channel. For several applications a further complete phenomenological view on SiPMs is necessary, defining several SiPM intrinsic parameters, i.e. gain fluctuation, afterpulsing, excess noise, dark count rate, prompt and delayed optical crosstalk, single photon time resolution (SPTR), photon detection effieciency (PDE) etc. These qualities of SiPMs influence directly and indirectly the time and energy resolution, for example in PET and HEP. This complete overview of all parameters allows one to draw solid conclusions on how best performances can be achieved for the various needs of the different applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical properties of intrinsic silicon at 300 K
Green, M. A., & Keevers, M. J. (1995) · Progress in Photovoltaics Research and Applications · doi:10.1002/pip.4670030303 · Cited by 1,364 · cited 1×
“(b) Light absorption length in Silicon (data from Green and Keevers 1995). n-doped region, connected to the positive pole of the bias voltage.”
BackgroundAvalanche photodiodes and quenching circuits for single-photon detection
Cova, S., Ghioni, M., Lacaita, A., Samori, C., & Zappa, F. (1996) · Applied Optics · doi:10.1364/ao.35.001956 · Cited by 1,114
Silicon photomultiplier and its possible applications
Buzhan, P., Dolgoshein, B., Filatov, L., Ilyin, A., Kantzerov, V., Kaplin, V., Karakash, A., Kayumov, F., Klemin, S., Popova, E., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)00749-6 · Cited by 636
Electric field effect on the thermal emission of traps in semiconductor junctions
Vincent, G., Chantre, A., & Bois, D. (1979) · Journal of Applied Physics · doi:10.1063/1.326601 · Cited by 535 · cited 1×
“In silicon the primary dark count rate is due to the thermal generation of carriers by states in the bandgap and it can be modeled using Shockley–Read–Hall (SRH) statistics (Vincent et al 1979).”
MethodGeiger-mode avalanche photodiodes, history, properties and problems
Renker, D. (2006) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2006.05.060 · Cited by 496
Advances in solid state photon detectors
Renker, D., & Lorenz, E. (2009) · Journal of Instrumentation · doi:10.1088/1748-0221/4/04/p04004 · Cited by 385 · cited 4×
“Picture modified from Renker and Lorenz (2009). photodiode (APD).”
BackgroundMethodInfluentialUnderstanding and simulating SiPMs
Acerbi, F., & Gundacker, S. (2018) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2018.11.118 · Cited by 385 · cited 2×
“Of course in the design of a SPAD additional factors like the exact doping profile, drift regions, field distribution and junction depth will influence the final detection efficiency (Acerbi and Gundacker 2019).”
BackgroundMethodSelf-citationTime of flight in PET revisited
Moses, W. W. (2003) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2003.817319 · Cited by 336
The digital silicon photomultiplier — Principle of operation and intrinsic detector performance
Frach, T., Prescher, G., Degenhardt, C., de Gruyter, R., Schmitz, A., & Ballizany, R. (2009) · 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) · doi:10.1109/nssmic.2009.5402143 · Cited by 317
On the bremsstrahlung origin of hot-carrier-induced photons in silicon devices
Lacaita, A. L., Zappa, F., Bigliardi, S., & Manfredi, M. (1993) · IEEE Transactions on Electron Devices · doi:10.1109/16.199363 · Cited by 288 · cited 2×
“The amount has been estimated to 3 · 10−5 photons per avalanche carrier (Lacaita et al 1993, Otte 2009).”
Background
Metadata
- Authors
- Gundacker, S., & Heering, A.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2020-08-19
- Volume
- 65
- Issue
- 17
- Pages
- 17TR01
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W3007319830
- Cited by
- 237
- References
- 56
- FWCI
- 20.58
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The silicon photomultiplier: fundamentals and applications of a modern solid-state photon detector. https://app.cochat.ai/papers/10.1088/1361-6560/ab7b2d
- The paper
- Gundacker, S., & Heering, A. (2020). The silicon photomultiplier: fundamentals and applications of a modern solid-state photon detector. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/ab7b2d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.