Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 19 of the 20 references it cites were found in a registry or an index.

Operation of a three phase solid state-Transformer under unbalanced load conditions

Venkat, Jakka, Shukla, Anshuman, Kulkarni, S. V. · 2014 · 2014 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES)

Abstract

Solid state transformers (SSTs) have found widespread power applications in traction locomotives, distribution systems, smart grids, etc., where they are going to replace conventional transformers and associated power enhancement equipments to provide better power quality features and functionalities. An eminent structure of SST comprises of three power conversion stages: input (AC-DC), isolation (DC-DC), and output (DC-AC). Multilevel converters are incorporated in several SSTs for operating at high voltage levels. This paper presents a three phase multilevel converter based SST (MCSST) which contains Cascaded H Bridge (CHB) multilevel converters in its input stage. Most of the reported topologies of MCSST have a common low voltage DC (LVDC) bus and a common control block for the entire SST structure. The presented MCSST consists of three independent phase modules and each phase module is controlled separately. Therefore, the outputs of these modules can be applied to both three phase loads as well as three independent single phase loads. Such a configuration can also be used to operate effectively under unbalanced load conditions. The discussed analysis of the reported work is verified using PSCAD/EMTDC simulation results.

Overview

Integrity signals

Registry

Crossref · 10.1109/pedes.2014.7042116

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 20 references

Research works printed but not linked: 1

  1. 10.1049/iet-pel:20080004 · DOI · Paper page

Cited by

See all 12

Metadata

Authors
Venkat, J., Shukla, A., & Kulkarni, S. V.
Affiliations
Indian Institute of Technology Bombay (IN)
Venue
2014 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES)
Publisher
IEEE
Published
2014-12
Volume
27
Pages
1-6
OpenAlex
W2547219501
Cited by
12
References
20
Citations by year
2023: 3 · 2022: 1 · 2021: 1 · 2020: 2 · 2018: 3 · 2016: 2
FWCI
0.81
Type
conference paper
Language
en
Open access
closed
Locations
IEEE International Conference on Power Electronics, Drives and Energy Systems (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
Keywords
solid-state transformer, cascaded H-bridge converter, unbalanced loads, single-phase loads, AC-DC conversion, power quality

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Operation of a three phase solid state-Transformer under unbalanced load conditions. https://app.cochat.ai/papers/10.1109/pedes.2014.7042116
The paper
Venkat, J., Shukla, A., & Kulkarni, S. V. (2014). Operation of a three phase solid state-Transformer under unbalanced load conditions. 2014 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES). https://doi.org/10.1109/pedes.2014.7042116

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.