Abstract
Dc active distribution networks seem to be a technically viable solution where high transmission efficiency, power quality, reliability and distributed generation are required. Modern power conversion devices are to be employed in order to create such networks by connecting them to three-phase ac power systems. This work present the evaluation of two-level and three-level (NPC) bidirectional voltage source rectifier topologies for bipolar dc active networks from the perspective of power semiconductor efforts, efficiency, volume and weight. The evaluation methodology based on the rotating reference frame is used in the analysis of a 160 kVA NPC converter feeding unbalanced dc loads and the impact of this in the converter volume and weight is presented. Furthermore, the maximum dc-side load unbalance for the NPC rectifier is derived.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Three-phase PFC converters can provide a higher power level and further reduce the charging time [95].”
From A Review of Bidirectional On-Board Chargers for Electric Vehicles (2021) · cites this paper as [95]
Citations
Cites
A New Neutral-Point-Clamped PWM Inverter
Nabae, A., Takahashi, I., & Akagi, H. (1981) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1981.4503992 · Cited by 5,139 · cited 1×
“Two alternatives are evaluated for the bidirectional rectifier: (i) a three-phase two-level voltage source rectifier (VSR) (cf. Fig.”
MethodPulse Width Modulation for Power Converters
Holmes, D. G., & Lipo, T. A. (2003) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470546284 · Cited by 2,384
DC-Bus Signaling: A Distributed Control Strategy for a Hybrid Renewable Nanogrid
Schonbergerschonberger, J., Duke, R., & Round, S. D. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.882012 · Cited by 573
DC microgrid based distribution power generation system
Ito, Y., Yang, Z., & Akagi, H. (2004) · International Power Electronics and Motion Control Conference · Cited by 383
AC vs. DC distribution: A loss comparison
Starke, M., Tolbert, L. M., & Ozpineci, B. (2008) · 2008 IEEE/PES Transmission and Distribution Conference and Exposition · doi:10.1109/tdc.2008.4517256 · Cited by 257 · cited 1×
“Analyzes on possible dc network topologies show that high reliability and low transmission losses can be found employing a bipolar dc architecture [8]–[10].”
BackgroundSine-triangle versus space-vector modulation for three-level PWM voltage-source inverters
Wang, F. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/28.993172 · Cited by 237
Sine-triangle vs. space vector modulation for three-level PWM voltage source inverters
Wang, F. (2002) · Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129) · doi:10.1109/ias.2000.883171 · Cited by 222
The Feasibility of Small-Scale Residential DC Distribution Systems
Engelen, K., Shun, E. L., Vermeyen, P., Pardon, I., D’hulst, R., Driesen, J., & Belmans, R. J. M. (2006) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2006.347246 · Cited by 162
Lago, J., & Heldwein, M. L. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2105284 · Cited by 121 · cited 2×
“References [7], [11] propose the use of two types of voltage balancers connected to the output of a VSR to create the bipolar dc lines.”
BackgroundMethodSelf-citationAn LVDC distribution system concept
Salonen, P., Kaipia, T., Nuutinen, P., Peltoniemi, P., & Partanen, J. (2008) · Aaltodoc (Aalto University) · Cited by 116
Research works printed but not linked: 1
- baker, 1981, Bridge converter circuit
Cited by
A Review of Bidirectional On-Board Chargers for Electric Vehicles
Yuan, J., Dorn-Gomba, L., Callegaro, A. D., Reimers, J., & Emadi, A. (2021) · IEEE Access · doi:10.1109/access.2021.3069448 · Cited by 390
Topology Deduction and Analysis of Voltage Balancers for DC Microgrid
Wang, F., Lei, Z., Xu, X., & Shu, X. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2638959 · Cited by 193
“Consequently, the data centers from Intel and IBM have been utilizing the power distribution of ±190 or ±200 V instead, in order to enhance the reliability of power supplies [6]–[8].”
MethodBipolar DC Power Conversion: State-of-the-Art and Emerging Technologies
Rivera, S., Lizana F., R., Kouro, S., Dragicevic, T., & Wu, B. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2980994 · Cited by 187
“This lies in their proven cost-effectiveness, efficiency, and reliability, besides being the two most widespread three-phase converters employed in the industry [43].”
BackgroundInfluentialUpputuri, R. P., & Subudhi, B. (2023) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2023.3289965 · Cited by 180
“In addition, the three-phase bidirectional ac–dc converters like the full-bridge converter [65], NPC [66], and T-type [67] were extensively discussed in the literature.”
BackgroundThree-Level DC Converter for Balancing DC 800-V Voltage
Zhang, X., Gong, C., & Yao, Z. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2344016 · Cited by 82
Metadata
- Authors
- Moia, J., Lago, J., Perin, A. J., & Heldwein, M. L.
- Affiliations
- Universidade Federal de Santa Catarina (BR)
- ORCID
- Heldwein, M. L.
- Venue
- 2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)
- Publisher
- IEEE
- Published
- 2012-06
- Pages
- 221-228
- OpenAlex
- W2045423068
- Cited by
- 29
- References
- 20
- Citations by year
- 2025: 2 · 2024: 2 · 2023: 4 · 2022: 2 · 2021: 3 · 2020: 2 · 2019: 1 · 2018: 1 · 2017: 1 · 2016: 2 · 2015: 2 · 2014: 3 · 2013: 4
- FWCI
- 3.68
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) (publishedVersion)
- Funders
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Keywords
- three-phase PWM rectifier, neutral point clamped converter, power semiconductor devices, converter efficiency
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.