Bipolar DC Power Conversion: State-of-the-Art and Emerging Technologies
Open accessThe DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
This article provides a detailed analysis of the power electronics solutions enabling bipolar dc grids. The bipolar dc grid concept has proven to be more efficient, flexible, and higher in quality than the conventional unipolar one. However, despite its many features, these systems still have to overcome their issues with asymmetrical loading to avoid voltage imbalances, besides meeting regulatory and safety requirements that are still under development. Advances in power electronics and the large-scale deployment of dc consumer appliances have put this growing architecture in the spotlight, as it has drawn the attention of different research groups recently. The following provides an insightful discussion regarding the topologies that enable these architectures and their regulatory requirements, besides their features and level of development. In addition, some future trends and challenges in the further development of this technology are discussed to motivate future contributions that address open problems and explore new possibilities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recent Advances and Industrial Applications of Multilevel Converters
Kouro, S., Malinowski, M., Gopakumar, K., Pou, J., Franquelo, L. G., Wu, B., Rodriguez, J., Pérez, M. A., & Leon, J. I. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049719 · Cited by 3,872 · cited 1×
“Its versatility and functionality in a wide voltage-power combination make it a natural candidate to act as the distribution converter with high-power handling capabilities [52].”
BackgroundSelf-citationDC Microgrids–Part I: A Review of Control Strategies and Stabilization Techniques
Dragicevic, T., Lu, X., Vasquez, J., & Guerrero, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2478859 · Cited by 1,564 · cited 1×
“THE search for sustainable ways of generating electricity while promoting a transversal use of clean technologies is deeply transforming the electric system [1], [2].”
BackgroundSelf-citationDC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451 · cited 3×
“tectures or configurations, namely, the unipolar (also known as monopolar) and the bipolar [30].”
BackgroundSelf-citationLow-Voltage Bipolar-Type DC Microgrid for Super High Quality Distribution
Kakigano, H., Miura, Y., & Ise, T. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2077682 · Cited by 995 · cited 2×
“technology [25] and will be further elaborated in the following.”
BackgroundCelanovic, N., & Boroyevich, D. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.838096 · Cited by 915
The Essence of Three-Phase PFC Rectifier Systems—Part I
Kolar, J. W., & Friedli, T. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2197867 · Cited by 788 · cited 1×
“9% efficiency for a 400 V output [71], through an appropriate semiconductor effort.”
BackgroundProtection of Low-Voltage DC Microgrids
Salomonsson, D., Soder, L., & Sannino, A. (2009) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2009.2016622 · Cited by 712 · cited 1×
“Grounding LVDC systems is a complex issue, and it is mostly used for the detection of ground faults and for personnel and equipment safety [41], [42].”
Khaligh, A., & Dusmez, S. (2012) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2012.2213104 · Cited by 630 · cited 1×
“Given the increased requirements imposed in distributed generation systems, these stages should also provide an adjustable power factor, bidirectional power handling, high-quality input currents and dc voltage, and reduced filtering requirements while simultaneously providing high reliability and a reduced device coun…”
BackgroundLow-Voltage DC Distribution System for Commercial Power Systems With Sensitive Electronic Loads
Salomonsson, D., & Sannino, A. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2006.883024 · Cited by 561 · cited 5×
“, wind, small hydro, and wave/tidal energy conversion systems, and require power electronics devices to accommodate their output to network conditions [26].”
BackgroundInfluentialComparison of Traditional Inverters and $Z$-Source Inverter for Fuel Cell Vehicles
Shen, M., Joseph, A., Wang, J., Peng, F. Z., & Adams, D. J. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.900505 · Cited by 502
Cited by
Charging Infrastructure and Grid Integration for Electromobility
Rivera, S., Goetz, S. M., Kouro, S., Lehn, P. W., Pathmanathan, M., Bauer, P., & Mastromauro, R. A. (2023) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3216362 · Cited by 233
Self-citation
Metadata
- Authors
- Rivera, S., Lizana F., R., Kouro, S., Dragicevic, T., & Wu, B.
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2021-04
- Volume
- 9
- Issue
- 2
- Pages
- 1192-1204
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W3011191829
- Cited by
- 187
- References
- 54
- FWCI
- 9.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bipolar DC Power Conversion: State-of-the-Art and Emerging Technologies. https://app.cochat.ai/papers/10.1109/jestpe.2020.2980994
- The paper
- Rivera, S., Lizana F., R., Kouro, S., Dragicevic, T., & Wu, B. (2021). Bipolar DC Power Conversion: State-of-the-Art and Emerging Technologies. IEEE Journal of Emerging and Selected Topics in Power Electronics. https://doi.org/10.1109/jestpe.2020.2980994
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.