Cited by 22Electric Motor Design and AnalysisMachine Fault Diagnosis TechniquesSensorless Control of Electric Motors

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Detection of magnet demagnetization in five-phase surface-mounted permanent magnet generators

Casadei, D., Filippetti, F., Mengoni, M., Gritli, Y., Serra, G., Tani, A., Zarri, L.·2012·2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)

Abstract

Multiphase generators are attractive particularly for medium and high power applications, because this technology allows reducing the current per phase and consequently the requirements of the inverter switches. The interest in multiphase machines is motivated also by their greater number of degrees of freedom compared to three-phase machines. This characteristic is often used to improve the machine performance, to increase the power density or for diagnostic purposes. In particular, the condition monitoring of the status of the magnets in permanent magnet synchronous generators is critical and is receiving an increasing attention. In this paper, the demagnetization of the rotor magnet trailing edges due to abnormal stator currents in five-phase surface-mounted permanent magnet synchronous generators is analyzed. A new non-invasive on-line detection method, which emphasizes the emf variation due to the demagnetization, exploiting the additional degrees of freedom of a multiphase generator, is presented. The proposed approach is validated by means of finite element analysis and numerical simulations.

Overview

Integrity signals

Registry

Crossref · 10.1109/pedg.2012.6254099

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • PI controller outputs have been used as diagnostic signals when decoupling signals are applied in control paths or when the control structure is extended with additional PI regulators to compensate for damage.

    “-PI controller outputs in the case that the decoupling signals are applied in the control paths, e.g.[179] or when the control structure is extended with some additional PI regulators to compensate for the damage [180];”

Citations

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Metadata

Authors
Casadei, D., Filippetti, F., Mengoni, M., Gritli, Y., Serra, G., Tani, A., & Zarri, L.
Affiliations
University of Bologna (IT)
Venue
2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)
Publisher
IEEE
Published
2012-06
Pages
841-848
OpenAlex
W2024550125
Cited by
22
References
17
Citations by year
2025: 2 · 2022: 2 · 2019: 5 · 2018: 6 · 2017: 1 · 2015: 1 · 2014: 2 · 2013: 3
FWCI
2.45
Type
conference paper
Language
en
Open access
closed
Locations
  • IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) (publishedVersion)
  • Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
  • Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
Keywords
permanent magnet demagnetization, permanent magnet synchronous generator, multiphase generator, condition monitoring, non-invasive fault detection, online detection

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review